EEWORLDEEWORLDEEWORLD

Part Number

Search

ME102.020B22E

Description
Preset counters mechanic
File Size415KB,4 Pages
ManufacturerIVO ( Baumer )
Websitehttp://www.ivo.de/
Download Datasheet View All

ME102.020B22E Overview

Preset counters mechanic

Preset counters mechanic
Meter and revolution counters, subtracting
Display 4-digits, manual reset by button
ME102, UE102
Features
– Preset counter with one preset
– Meter or revolution counter
– Subtracting
– Display 4-digits
– With reset button
– Compact design
– Surface mount housing
ME102 - Meter counter
Technical data - mechanical design
Number of digits
Digit height
Count mode
4-digits
5.5 mm
Subtracting in a rotational
direction to be indicated, adding
in reverse direction
Both sides, ø4 mm
Manual by button to preset
≤0.8 Nm (with 1 rev. = 1 count)
≤0.4 Nm (with 50 rev. = 1 count)
See ordering part number
0...+60 °C
Surface mount housing
Grey
60 x 62 x 68.5 mm
Surface mount housing
350 g
Housing: Hostaform POM, grey
Cable 30 cm, 3 cores
Subject to modification in technic and design. Errors and omissions excepted.
2/12/2008
Drive shaft
Reset
Operating torque
Measuring range
Operating temperature
UE102 - Revolution counter
Technical data - electrical ratings
Preset
Preset setting
1 preset
Press reset button and hold.
Enter desired value in any
order. Release reset button.
Momentary contact at 0000
Permanent contact at 9999
Permanent precontact as
momentary contact
Change-over contact
230 VAC / VDC
2A
100 VA / 30 W
Recommended for inductive
load
Housing type
Housing colour
Dimensions W x H x L
Mounting
Weight approx.
Material
E-connection
Dimensions mounting plate 60 x 62 mm
Limit switch
Precontact
Output contact
Switching voltage
Switching current
Switching capacity
Spark extinguisher
1
www.baumerivo.com
VGA display Verilog driver code
[i=s] This post was last edited by paulhyde on 2014-9-15 03:18 [/i] VGA display Verilog driver code...
songshupine Electronics Design Contest
28335 ADC overvoltage protection circuit
First of all, does the ADC of TMS320F28335 need an accurate 3.0V overvoltage protection circuit? From the principle block diagram in the data sheet, I don't see any built-in protection circuit. The an...
Yuting Microcontroller MCU
c# DDE (Dynamic Data Exchange) client program, how to set up Server and Topic
As the title says. Since DDE is a very old technology, it has been replaced by OPC. But some things still need DDE. .net no longer supports DDE. Fortunately, I found a packaged API. The following is a...
ziyangcao Embedded System
LPC800-mini does not seem to be able to use Mbed
I tried to compile an Mbed program for LPC812 and changed the CPU to LPC810. The error message after compilation is as follows:It seems that there is not enough space to put the compiled code....
dcexpert NXP MCU
Will the simple setting cause assignment errors?
As the title says, in the ADS1.2 project settings, I set linktype to simple, RO Base: 0x30008000 (I checked, this address should be correct), but when assigning values to structure variables, errors a...
gwqnet Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 478  1523  193  633  99  10  31  4  13  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号