CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
NOTES:
1.
JA
is measured in free air with the component mounted on a high effective thermal conductivity test board with “direct attach” features. See
Tech Brief
TB379.
2. For
JC,
the "case temp" location is the center of the ceramic on the package underside
3. V
IN
= Input Voltage to Perform Proper Function.
4. Signals on S
X
, D
X
or IN
X
exceeding V+ or V- will be clamped by internal diodes. Limit forward diode current to maximum current ratings.
DC Electrical Specifications
Device Tested at: V+ = +15V, V- = -15V, V
L
= 5V, GND = 0V, Unless Otherwise Specified.
LIMITS
GROUP A
SUBGROUP
1, 3
2
TEMPERATURE
(°C)
+25, -55
+125
MIN
(Note 5)
0
0
MAX
(Note 5)
35
45
PARAMETERS
Drain-to-Source
ON-Resistance
SYMBOL
r
DS(ON)
CONDITIONS
V+ = +13.5V,
V- = -13.5V,
I
S
= -10mA,
V
D
= ±8.5V
V
IN
= 0.8V
V+ = +10.8V,
V- = -0V,
I
S
= -10mA,
V
D
= 3.0V and 8.0V
V
IN
= 0.8V
UNITS
1, 3
2
+25, -55
+125
0
0
80
100
Source OFF Leakage Current
I
S(OFF)
V+ = 16.5V,
V- = -16.5V,
V
D
= -15.5V,
V
S
= 15.5V
V
IN
= 2.4V
V+ = 16.5V,
V- = -16.5V,
V
D
= 15.5V,
V
S
= -15.5V
V
IN
= 2.4V
1
2, 3
+25
+125, -55
-0.25
-20
+0.25
+20
nA
nA
1
2, 3
+25
+125, -55
-0.25
-20
+0.25
+20
nA
nA
Drain OFF Leakage Current
I
D(OFF)
V+ = 16.5V,
V- = -16.5V,
V
D
= -15.5V,
V
S
= 15.5V
V
IN
= 2.4V
V+ = 16.5V,
V- = -16.5V,
V
D
= 15.5V,
V
S
= -15.5V
V
IN
= 2.4V
1
2, 3
+25
+125, -55
-0.25
-20
+0.25
+20
nA
nA
1
2, 3
+25
+125, -55
-0.25
-20
+0.25
+20
nA
nA
FN6726 Rev 1.00
Jan 24, 2014
Page 3 of 10
DG411/883
DC Electrical Specifications
Device Tested at: V+ = +15V, V- = -15V, V
L
= 5V, GND = 0V, Unless Otherwise Specified.
(Continued)
LIMITS
PARAMETERS
Channel ON Leakage Current
SYMBOL
CONDITIONS
GROUP A
SUBGROUP
1
2, 3
1, 2, 3
TEMPERATURE
(°C)
+25
+125, -55
+25, +125, -55
MIN
(Note 5)
-0.4
-40
-0.5
MAX
(Note 5)
+0.4
+40
+0.5
UNITS
nA
nA
µA
I
D(ON) +
I
S(ON)
V+ = 16.5V,
V- = -16.5V,
V
S
= V
D
= ±15.5V
I
IL
Input Under
Test = 0.8V,
All Others = 2.4V
Input Under
Test = 2.4V,
All Others = 0.8V
V+ = 16.5V,
V- = -16.5,
V
IN
= 0V or 5.0V
V+ = 13.2V, V- = 0V,
V
IN
= 0V or 5.0V
V
L
= 5.25V
Input Current with V
IN
Low
Input Current with V
IN
High
I
IH
1, 2, 3
+25, +125, -55
-0.5
+0.5
µA
Positive Supply Current
I+
1
2, 3
1
2, 3
1
2, 3
1
2, 3
1
2, 3
1
2, 3
1
2, 3
1
2, 3
+25
+125, -55
+25
+125, -55
+25
+125, -55
+25
+125, -55
+25
+125, -55
+25
+125, -55
+25
+125, -55
+25
+125, -55
-
-
-
-
-1.0
-5.0
-1.0
-5.0
-
-
-
-
-1.0
-5.0
-1.0
-5.0
+1.0
+5.0
+1.0
+5.0
-
-
-
-
+1.0
+5.0
+1.0
+5.0
-
-
-
-
µA
µA
µA
µA
µA
µA
µA
µA
µA
µA
µA
µA
µA
µA
µA
µA
Negative Supply Current
I-
V+ = 16.5V,
V- = -16.5,
V
IN
= 0V or 5.0V
V+ = 13.2V, V- = 0V,
V
IN
= 0V or 5.0V
V
L
= 5.25V
Logic Supply Current
I
L
V+ = 16.5V,
V- = -16.5,
V
IN
= 0V or 5.0V
V+ = 13.2V, V- = 0V,
V
IN
= 0V or 5.0V
V
L
= 5.25V
Ground Current
I
GND
V+ = 16.5V,
V- = -16.5,
V
IN
= 0V or 5.0V
V+ = 13.2V, V- = 0V,
V
IN
= 0V or 5.0V
V
L
= 5.25V
AC Electrical Specifications
Device Tested at: V+ = +15V, V- = -15V, V
L
= 5V, GND = 0V, Unless Otherwise Specified.
LIMITS
PARAMETERS
Turn ON Time
SYMBOL
t
ON
CONDITIONS
C
L
= 35pF, V
S
= ±10V,
R
L
= 300
V+ = 12V, V- = 0V,
C
L
= 35pF, V
S
= +8V,
R
L
= 300
GROUP A
SUBGROUP
9, 11
10
9, 11
10
9, 11
10
9, 11
10
TEMPERATURE
(°C)
+25, -55
+125
+25, -55
+125
+25, -55
+125
+25, -55
+125
MIN
(Note 5)
0
0
0
0
0
0
0
0
MAX
(Note 5)
175
240
250
400
145
160
125
140
UNITS
ns
ns
ns
ns
ns
ns
ns
ns
Turn OFF Time
t
OFF
C
L
= 35pF, V
S
= ±10V,
R
L
= 300
V+ = 12V, V- = 0V,
C
L
= 35pF, V
S
= +8V,
R
L
= 300
FN6726 Rev 1.00
Jan 24, 2014
Page 4 of 10
DG411/883
Electrical Specifications
Device Tested at: V+ = +15V, V- = -15V, V
L
= 5V, GND = 0V, Unless Otherwise Specified.
LIMITS
PARAMETERS
Charge Injection
SYMBOL
Q
CONDITIONS
V
G
= 0V, R
G
= 0, T
A
= +25°C,
C
L
= 10nF (see Figure 2)
V
G
= 6V, R
G
= 0, T
A
= +25°C
C
L
= 10nF, V+ = 12V, V- = 0V
(see Figure 2)
NOTE:
5. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by characterization
and are not production tested.
TABLE 2. ELECTRICAL TEST REQUIREMENTS
MIL-STD-883 TEST REQUIREMENTS
Interim Electrical Parameters (Pre Burn-In)
Final Electrical Test Parameters
Group A Test Requirements
Groups C and D Endpoints
NOTE:
6. PDA applies to Subgroup 1 only.
SUBGROUPS (See “Electrical Spec Tables” on page 3 and page 4)