8162 Paired - Low Capacitance Computer Cable for EIA RS-232/422 & Digital
For more information please
call
1-800-Belden1
See Put-ups and Colors
Related Documents : No. 3 for
Paired Cables (Belden
Standard).pdf
Description:
24 AWG stranded (7x32) TC conductors, Datalene® insulation, twisted pairs individually Beldfoil® shielded + overall 100% Beldfoil + TC
braid shield (65% coverage), drain wire, PVC jacket
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Pairs
Total Number of Conductors
AWG
Stranding
Conductor Material
INSULATION:
Insulation Material Trade Name
Insulation Material
Lay Length
Twists/ft.
Pair Color Code Chart :
Number
1
INNER SHIELD:
Inner Shield Material Trade Name
Inner Shield Type
Inner Shield Material
Inner Shield % Coverage
Inner Shield Drain Wire AWG
Inner Shield Drain Wire Stranding
Inner Shield Drain Wire Conductor Material
OUTER SHIELD:
Outer Shield Material Trade Name
Beldfoil® (Z-Fold®)
Page 1 of 3
2
4
24
7x32
TC - Tinned Copper
Datalene®
FPE - Foam Polyethylene
1 in.
12
Color
Black & Red
Number
2
Color
Black & White
Beldfoil®
Tape
Aluminum Foil-Polyester Tape
100 %
24
7x32
TC - Tinned Copper
8162 Paired - Low Capacitance Computer Cable for EIA RS-232/422 & Digital
Outer Shield Type
Outer Shield Material :
Layer Number
1
2
Outer Shield %Coverage
OUTER JACKET:
Outer Jacket Material
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter
MECHANICAL CHARACTERISTICS:
Operating Temperature Range
Non-UL Temperature Rating
Bulk Cable Weight
Max. Recommended Pulling Tension
Min. Bend Radius (Install)
Material Trade Name
Beldfoil®
Tape/Braid
Type
Tape
Braid
100 %
Material
Aluminum Foil-Polyester
Tape
TC - Tinned Copper
% Coverage (%)
100
65
PVC - Polyvinyl Chloride
.343 in.
-40°C To +60°C
60°C (UL AWM Style 2493)
66 lbs/1000 ft.
63 lbs.
3.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
CEC/C(UL) Specification
AWM Specification
EU CE Mark (Y/N)
EU RoHS Compliant (Y/N)
EU RoHS Compliance Date (mm/dd/yyyy):
FLAME TEST:
UL Flame Test
PLENUM/NON-PLENUM:
Plenum (Y/N)
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance
Nom. Capacitance Conductor to Conductor @ 1 KHz
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz
Nominal Velocity of Propagation
Nom. Conductor DC Resistance @ 20 Deg. C
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C
Nominal Outer Shield DC Resistance @ 20 Deg. C
100 Ohms
12.5 pF/ft
22 pF/ft
78 %
24.0 Ohms/1000 ft
18 Ohms/1000 ft
4.3 Ohms/1000 ft
Page 2 of 3
CM
CM
UL Style 2493 (300 V 60°C)
Yes
Yes
01/01/2004
VW-1, UL1685 UL Loading
N
8162 Paired - Low Capacitance Computer Cable for EIA RS-232/422 & Digital
Max. Operating Voltage - UL
Max. Recommended Current
NOTES:
Notes
300 V RMS
1.8 Amps per conductor @ 25°C
Datalene® insulation features include low dielectric constant and a dissipation
factor for high-speed, low-distortion data handling. Physical properties include good
crush resistance and light weight.
PUT-UPS AND COLORS:
Item
Description
8162 060100
2 FS PR #24 FHDPE
SH PVC
8162 0601000
2 FS PR #24 FHDPE
SH PVC
8162 060500
2 FS PR #24 FHDPE
SH PVC
C = CRATE REEL PUT-UP.
Revision Number: 1
Put-Up (ft.)
100
1000
500
Ship Weight (lbs.)
6.2
57
30
Jacket Color
CHROME
CHROME
CHROME
Notes
C
C
Revision Date: 07-25-2005
© Copyright 2006 Belden, Inc
All Rights Reserved.
Although Belden ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and
specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described
herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with the following environmental regulations: California Proposition 65 Consent Judgment
For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS (Directive 2002/95/EC, 27-Jan-
2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our Distributor's inventory. EU
ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR (Directive 2003/11/EC, 6-Feb-
2003). The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the
Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its publication. The information
provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product
itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory
information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations
based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3