C. Valid provided the terminals are kept at ambient
temperature
*Pin Configuration - Top View
Suggested Solder
Pad Layout
.031
.800
.035
.900
.079
2.000
inches
mm
.037
.950
.037
.950
Revision:
11
www.mccsemi.com
1 of 5
2007/07/04
MCC
BZX84C2V4 thru BZX84C51
ELECTRICAL CHARACTERISTICS (Ta=25 C unless otherwise noted)
o
TM
Micro Commercial Components
Nominal Zener Voltage
Part Number
Marking
Nom.
2.4
2.7
3
3.3
3.6
3.9
4.3
4.7
5.1
5.6
6.2
6.8
7.5
8.2
9.1
10
11
12
13
15
16
18
20
22
24
27
30
33
36
39
43
47
51
Vz(V) @ I
ZT
Min.
2.28
2.5
2.8
3.1
3.4
3.7
4
4.4
4.8
5.2
5.8
6.4
7
7.7
8.5
9.4
10.4
11.4
12.4
13.8
15.3
16.8
18.8
20.8
22.8
25.1
28
31
34
37
40.85
44.65
48.45
Max.
2.52
2.9
3.2
3.5
3.8
4.1
4.6
5
5.4
6
6.6
7.2
7.9
8.7
9.6
10.6
11.6
12.7
14.1
15.6
17.1
19.1
21.2
23.3
25.6
28.9
32
35
38
41
45.15
49.35
53.55
Max. Zener Impedance
Z
ZT
@ I
ZT
Ohm
mA
100
5
100
5
95
5
95
5
90
5
90
5
90
5
80
5
60
5
40
5
10
5
15
5
15
5
15
5
15
5
20
5
20
5
25
5
30
5
30
5
40
5
45
5
55
5
55
5
70
5
80
2
80
2
80
2
90
2
130
2
150
5
170
5
100
5
Z
ZK
@ I
ZK
Ohm
mA
600
1
600
1
600
1
600
1
600
1
600
1
600
1
500
1
480
1
400
1
150
1
80
1
80
1
80
1
100
1
150
1
150
1
150
1
170
1
200
1
200
1
225
1
225
1
250
1
250
1
300
1
300
1
325
1
350
1
350
1
375
1
375
1
400
1
o
BZX84C2V4
BZX84C2V7
BZX84C3V0
BZX84C3V3
BZX84C3V6
BZX84C3V9
BZX84C4V3
BZX84C4V7
BZX84C5V1
BZX84C5V6
BZX84C6V2
BZX84C6V8
BZX84C7V5
BZX84C8V2
BZX84C9V1
BZX84C10
BZX84C11
BZX84C12
BZX84C13
BZX84C15
BZX84C16
BZX84C18
BZX84C20
BZX84C22
BZX84C24
BZX84C27
BZX84C30
BZX84C33
BZX84C36
BZX84C39
BZX84C43
BZX84C47
BZX84C51
W1/Z11
W2/Z12
W3/Z13
W4/Z14
W5/Z15
W6/Z16
W7/Z17
W8/Z1
W9/Z2
WA/Z3
WB/Z4
WC/Z5
WD/Z6
WE/Z7
WF/Z8
WG/Z9
WH/Y1
WI/Y2
WK/Y3
WL/Y4
WM /Y5
WN/Y6
WO/Y7
WP/Y8
WR/Y9
WS/Y10
WT /Y11
WU/Y12
WW/Y13
WX/Y14
WY
WZ
XA
Max.Reverse
Leakage
Current
IR @ VR
µA
V
50
1.0
20
1.0
10
1.0
5
1.0
5
1.0
3
1.0
3
1.0
3
2.0
2
2.0
1
2.0
3
4.0
2
4.0
1
5.0
0.7
5.0
0.5
6.0
0.2
7.0
0.1
8.0
0.1
8.0
0.1
8.0
0.1
10.5
0.1
11.2
0.1
12.6
0.1
14.0
0.1
15.4
0.1
16.8
0.1
18.9
0.1
21.0
0.1
23.1
0.1
25.2
0.1
27.3
0.1
30.10
0.1
32.90
0.1
35.70
NOTE:
1.Standard zener voltage tolerance is +/- 5% with a 'C' suffix from BZX84C2V4~BZX84C51 , suffix 'B' is +/- 2% tolerance from BZX84B4V3~BZX84B39.
2.Zener Voltage (Vz) Measurement. Guarantees the zener voltage when measured at 90 seconds while maintaining the lead temperature (TL) AT 30 C,from the diode body.
3.Zener Impedance (Zz) Derivation. The zener impedance os dervied from the 60 cycle ac voltage, which results when an AC current having an rms value equal to 10% of the
dc zener current (Izt or Izk) is superimposed on Izt or Izk.
4.Surge Current (IR) Non-Repetitive. The rating listed in the electrical characteristics table is maximum peak, non-repetitive, reverse surge current of 1/2 square wave or equivalent
sine wave pulse of 1/120 second duration superimposed on the test current, Izt, per JEDEC registration; however, actual device capability is as described in Figure 5.
O
Revision:
11
www.mccsemi.com
2 of 5
2007/07/04
BZX84C2V4 thru BZX84C51
8
7
MCC
Micro Commercial Components
100
10
TM
TEMPERATURE COEFFICIENT,mV /
o
C)
6
5
4
3
2
1
0
-1
-2
-3
2
3
4
5
6
7
8
9
10
11
12
TEMPERATURE COEFFICIENT,mV /
o
C)
1
10
100
NOMINAL ZENER VOLTAGE, Volts
NOMINAL ZENER VOLTAGE, Volts
TYPICAL REVERSE CURRENT
TEMPERATURE COEFFICIENTS
1000
DYNAMIC IMPEDANCE,
W
1000
IZ = 1 mA
FORWARD CURRENT, mA
T
J
=25
O
C
I
Z(AC)=0.1
I
Z(DC)
F=1 kHZ
100
5 mA
100
20 mA
10
10
150
O
C
75
O
C
25 C
O
5C
O
1
1
10
NORMAL ZENER VOLTAGE, Volts
100
1
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
FORWARD VOLTAGE, Volts
EFFECT OF ZENER VOLTAGE ON ZENER IMPEDANCE
TYPICAL FORWARD VOLTAGE
1000
1.2
1.0
0.8
0.6
POWER DISSIPATION, Watts
CAPACITANCE, pF
0 V BIAS
1 V BIAS
100
BIAS AT
50% OF VZ NOM
10
T
A
=25 C
o
0.4
0.2
1
0
1
10
100
0
25
50
75
100
125
150
TEMPERATURE (
o
C)
NOMINAL ZENER VOLTAGE, Volts
STEADY STATE POWER DERATING
TYPICAL CAPACITANCE
Revision:
11
www.mccsemi.com
3
of 5
2007/07/04
BZX84C2V4 thru BZX84C51
100
T
A
=25
o
C
ZENER CURRENT, mA
ZENER CURRENT, mA
MCC
Micro Commercial Components
100
T
A
=25
o
C
TM
10
10
1
1
0.1
0.1
0.01
0
2
4
6
8
10
12
0.01
10
30
50
70
90
ZENER VOLTAGE, Volts
ZENER VOLTAGE, Volts
ZENER VOLTAGE V.S. ZENER CURRENT
ZENER VOLTAGE V.S. ZENER CURRENT
1000
LEAKAGE CURRENT (
m
A)
100
10
1
0.1
0.01
0.001
0.0001
0.00001
0
10
20
30
40
50
60
70
+150
O
C
+25
O
C
-55 C
80
90
O
NOMINAL ZENER VOLTAGE, Vlots
TYPICAL LEAKGE CURRENT
Revision:
11
www.mccsemi.com
4 of 5
2007/07/04
MCC
Micro Commercial Components
TM
***IMPORTANT NOTICE***
Micro Commercial Components Corp
.
reserves the right to make changes without further notice to any
product herein to make corrections, modifications , enhancements , improvements , or other changes .
Micro Commercial Components Corp
.
does not assume any liability arising out of the application or
use of any product described herein; neither does it convey any license under its patent rights ,nor
the rights of others . The user of products in such applications shall assume all risks of such use
and will agree to hold
Micro Commercial Components Corp
.
and all the companies whose
products are represented on our website, harmless against all damages.
First of all, RF engineers must master the technology of circuit system analysis, which is also an indispensable part of engineering. In some communication equipment companies' projects, RF engineers ...
Cold chain intelligent management system based on CH2601
Author: Liu JianhuaProject BackgroundThe author has been engaged in immunization planning for a long time. The top priority of immunization pla...
Author: Stupid Pig has been busy recently and has no time to write articles. In fact, articles are easy to write, but data is difficult to collect. Not long ago, I saw an article on the Internet title...
Time flies so fast. I didn’t expect that I would watch these courses for 7 hours!To be honest, although I often take the initiative to check out the latest developments of MSP430, many of its new feat...
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
EtherCAT (Ethernet for Control Automation Technology) is a real-time industrial fieldbus communication protocol based on an Ethernet-based development framework. EtherCAT is one of the fastest indu...[Details]
1. Project Overview
1.1 Introduction
Currently, most music files are saved in MP3 format, a lossy audio compression format that cannot perfectly reproduce the original music. With the exp...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
Ever since the Tesla fire incident, electric cars, already known for their poor reputation, have been subjected to even more scathing criticism. Despite this, many people are still willing to buy t...[Details]
In recent years, with the application of the IEC61850 standard and the development and deployment of optoelectronic transformers, the concept of digital substations has been put into practical use ...[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
Since the beginning of this year, price wars have intensified, new models have been launched one after another, used cars with zero kilometers have become a hot topic, and the industry's internal c...[Details]
While the current industry consensus is that autonomous vehicles are robots and that their systems are managed using robotics-developed thinking, there are also cases where autonomous driving is ac...[Details]
Laird Thermal Systems has introduced the HiTemp ET series Peltier cooler modules, which can operate at high temperatures and provide on-site cooling for sensitive electronic devices.
Dig...[Details]
Through AI connection technology supported by Qualcomm X85 5G modem and RF and Qualcomm FastConnect 7900 mobile connection system, seamless switching can be achieved between cellular net...[Details]
In daily life, power transformers have different functions and uses due to different usage scenarios. The most common ones can be divided into: control transformers, isolation transformers, rectifi...[Details]
1. Fault phenomenon and cause analysis
1. During the operation of the equipment, the expansion sleeve is subjected to a large torque, and the mating surfaces of the shaft and the sleeve move...[Details]
A tubular motor is an electric motor that is typically used to control the movement of machines and equipment. Tubular motors are generally divided into two categories: linear tubular motors and ro...[Details]
In the field of communications power supplies, AC/DC rectifier power supplies are called primary power supplies or basic power supplies, while DC/DC converters are called secondary power supplies. ...[Details]