Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 20 operations/min
1
D2FW-G
Characteristics
Item
Permissible operating speed
Permissible
operating frequency
Insulation resistance
Contact resistance (initial value)
Between terminals of the same
polarity
Mechanical
Electrical
Model
D2FW-G2 models
1mm to 500mm/s
120 operations/min
30 operations/min
M4 Mounting Sealed Basic Switch
Mounting Holes
(Unit: mm)
D2FW-G0 models
M4 Tap
16
100 MΩ min. (at 500 VDC with insulation tester)
100 mΩ max.
150 mΩ max.
4
+0.1
dia. holes
0
(depth: 2mm min.)
600 VAC 50/60 Hz for 1 min
1,500 VAC 50/60 Hz for 1 min
1,500 VAC 50/60 Hz for 1 min
10 to 55 Hz, 1.5 mm double amplitude
1,000 m/s
2
{approx. 100G} max.
300 m/s
2
{approx. 30G} max.
300,000 operations min. (60 operations/min)
30,000 operations min.
(20 operations/min)
100,000 operations min.
(20 operations/min)
D
2
F
W
G
-
Dielectric strength
Between current-carrying metal
parts and ground
Between each terminal and
non-current-carrying metal parts
Vibration resistance
*1
Shock resistance
Malfunction
Durability
Malfunction * 1
Mechanical
Durability * 2
Degree of protection
Electrical
IEC IP67
-40°C to
+85°C
(at ambient humidity 60% max.)
(with no icing or condensation)
95% max. (for
+5°C
to
+35°C)
Approx. 10.4 g (for SPDT model)
Ambient operating temperature
Ambient operating humidity
Weight
Note. The data given above are initial values.
*1. The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel
Position value for lever. Close or open circuit of the contact is 1ms max.
*2. For testing conditions, consult your OMRON sales representative.
Dimensions
(Unit: mm)
/Operating Characteristics
The
@
is replaced with the code for the ratings and the contact forms. See the "List
of Models"
for available combinations of shapes.
●Leaf
lever
D2FW-G#7#M
t0.2 Stainless-steel lever
22.8
16
±0.15
2
A
8
5
2
Operating Characteristics
Operating Force
Releasing Force
OF
RF
Type
Model
Max.
Min.
Min.
Max.
Leaf lever
D2FW-G#7#M
2.45N {250 gf}
0.29N {30 gf}
1.0 mm
1.0 mm
15.5 mm
11.5±2 mm
6.5 mm (reference value)
4.2
+0.2
dia.
0
4
4
+0.2
dia.
0
D2FW G
0
0.15
dia.
5
Free
Position
Operating
Position
13.5
Overtravel
OT
Movement Differential MD
Free Position
Operating Position
Total Travel Position
R3.5
300
±10
FP Max.
OP
TTP
Lead wire
COM AVS0.5 (Black)
NO AVS0.5 (Blue)
NC AVS0.5 (Red)
4.7
15.3
23.5
5
●Long
leaf lever
D2FW-G#8#M
t0.2 Stainless-steel lever
19
16
±0.15
2
A
8
5
2
Operating
Characteristics
Operating Force
Releasing Force
OF
RF
Type
Model
Max.
Min.
Min.
Max.
Long leaf lever
D2FW-G#8#M
2.94N {300 gf}
0.59N {60 gf}
1.0 mm
1.0 mm
19 mm
12±2 mm
8.5 mm (reference value)
4.2
+0.2
dia.
0
4
4
+0.2
dia.
0
D2FW G
0
0.15
dia.
5
Free
Position
Operating
Position
13.5
Overtravel
OT
Movement Differential MD
Free Position
Operating Position
Total Travel Position
FP Max.
OP
TTP
R3.5
300
±10
Lead wire
COM AVS0.5 (Black)
NO AVS0.5 (Blue)
NC AVS0.5 (Red)
4.7
15.3
23.5
5
Note1. Unless otherwise specified, a tolerance of
±0.4
mm applies to all dimensions.
Note2. The operating characteristics are for operation in the A direction ( ).
2
D2FW-G
Precautions
★Please
refer to "Basic Switches Common Precautions" for correct use.
M4 Mounting Sealed Basic Switch
Cautions
Use the Switch within the specified Voltage rating. Using the
Switch outside of the rated values will not only shorten its
durability but may cause heat generation or fire damage. When
turning the power ON or OFF, use the rated voltage and current.
Correct Use
●Mounting
• Turn OFF the power supply before mounting or removing the
Switch, wiring, or performing maintenance or inspection.
Failure to do so may result in electric shock or burning.
• Use M4 mounting screws with plane washers or spring
washers to securely mount the Switch. Tighten the screws to a
torque of 1.18 to 1.47N·m {12 to 15 kgf·cm}.
●Degree
of Protection
Do not use the Switch underwater.
The Switch was tested and found to meet the conditions
necessary to meet the following standards. The test checks for
water intrusion after immersion for a specified time period, not for
switching operation underwater.
JIS C0920:
Degrees of protection provided by enclosures of electrical
apparatus (IP Code)
IEC 60529:
Degrees of protection provided by enclosures (IP Code)
Degree of protection: IP67
(check water intrusion after immersion
for 30 min. submerged 1m underwater)
●Switch
Mounting
When mounting the Switch, do not apply force to the actuator in
any direction other than its operating direction.
D
2
F
W
G
-
●Operation
Make sure that the switching object is perfectly separated from
the actuator when it is at the free position and the actuator is
pressed appropriately by the switching object when the switch is
operated.
The switching object must not move beyond its total travel
position, otherwise the Switch may be damaged.
Install the switching object so that its moving direction is the
same as that of the actuator.
●Protection
Against Chemicals
Prevent the Switch from coming into contact with oil or
chemicals.
Otherwise, damage to or deterioration of Switch materials may
result.
●Using
Micro Loads
• Even when using micro load models within the operating
range shown below, if inrush/surge current occurs, it may
increase the contact wear and so decrease durability.
Therefore, insert a contact protection circuit where necessary.
• The minimum applicable load is the N-level reference value.
This value indicates the malfunction reference level for the
reliability level of 60% (λ
60
).
(JIS C5003)
The equation,
λ
60
=0.5×10
-6
/operations, indicates that the
1
estimated malfunction rate is less than
2,000,000
operations
with a reliability level of 60%.
Voltage (V)
0.16 mA
16.6 mA 100 mA
30
24
Operating range
for micro load
models
D2FW-G0#
12
Operating
range for
general-load
models
D2FW-G2#
5
0
0.1
1mA
1
10
100
1,000
Current (mA)
3
D2FW-G
M4 Mounting Sealed Basic Switch
D
2
F
W
G
-
•
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
•
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.