PCB Relay
G6DS
Slim, Miniature Relay with 1-pole 5-A
Switching Capability
• Slim 5-mm width and miniature size.(20.3 x 5.08 x 12.5 mm max.)
• Ideal for high-density mounting.
• Delivers high switching performance (5 A at 250 VAC/30 VDC) and
enables various loads all in a slim, miniature size.
• Highly sensitive coil type (120 mW) also available.
• Satisfies EN 61131-2 (PLC) and EN 61010 (measuring instrument/
control equipment) reinforced insulation requirement.
• P6DS-04P Socket allows for easy installation and removal of Relays.
• RoHS compliant.
Model Number Structure
■
Model Number Legend
G6DS -
1
2
-
3
DC
4
4. Rated Coil Voltage
5, 12, 24
1. Number of Poles
1:
1 pole
2. Contact Form
A:
SPST-NO
3. Classification
None: Standard
H:
High-sensitivity
Applications
Applications include: PLCs, I/O modules, I/O ports, Timers, Temperature Controllers, and Control Boards.
Ordering Information
Classification
Standard
High-sensitivity
SPST-NO
Contact form
Enclosure ratings
Fully sealed
G6DS-1A
G6DS-1A-H
Model
Note:
When ordering, add the rated coil voltage to the model number.
Example: G6DS-1A DC12
Rated coil voltage
■
Accessories (Order Separately)
Connecting Socket
Relay Pullout Tool
P6DS-04P
R99-01 for G6DS
PCB Relay
G6DS
131
■
Coil Ratings
Item
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
5 VDC
36 mA
139
Ω
Standard
12 VDC
15 mA
800
Ω
24 VDC
7.5 mA
3,200
Ω
5 VDC
24 mA
208
Ω
High-sensitivity
12 VDC
10 mA
1,200
Ω
24 VDC
5 mA
4,800
Ω
70% max. of rated voltage
5% min. of rated voltage
160% of rated voltage (at 23°C)
Approx. 180 mW
Approx. 120 mW
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
2.
“Max. voltage” refers to voltage that can be applied to the relay coil momentarily. Do not apply "Max. voltage" continuously.
■
Contact Ratings
Item
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value) (See note.)
Note:
P level:
λ
60
= 0.1
×
10
−6
Resistive load (cos
φ=1)
5 A at 250 VAC, 5 A at 30 VDC
5A
250 VAC, 30 VDC
5A
1,250 VA, 150 W
5 mA at 24 VDC
operation
Inductive load (cos
φ=0.4,
L/R=7 ms)
2 A at 250 VAC, 2 A at 30 VDC
■
Characteristics
Contact resistance (See note 1.)
Operate time
Release time
Insulation resistance (See note 2.)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
Ambient temperature
Ambient humidity
Weight
100 mΩ max.
10 ms max.
5 ms max.
1,000 MΩ min. (at 500 VDC)
3,000 VAC, 50/60 Hz for 1 min. between coil and contacts
750 VAC, 50/60 Hz for 1 min. between contacts of same polarity
6,000 V (1.2
×
50
μs)
between coil and contacts
10 to 55 to 10 Hz, 1.5-mm double amplitude
10 to 55 to 10 Hz, 1.5-mm double amplitude
1,000 m/s
2
150 m/s
2
(standard type); 130 m/s
2
(high-sensitivity type)
20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. for standard type; 80,000 operations min. for high sensitivity type (1,800
operations/hr @ 23°C)
Operating:
−40°C
to 85°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 2.3 g
Note: 1.
The data shown above are initial values.
2.
The contact resistance is derived using voltage drop method with 1 A applied at 5 VDC.
3.
The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
132
PCB Relay
G6DS
Engineering Data
Maximum Switching Power
Switching current (A)
50
30
Endurance
Endurance (x10
4
operations)
500
300
Ambient Temperature vs.
Maximum Coil Voltage
Maximum coil voltage (%)
200
180
160
140
120
100
80
60
0
10
5
3
AC resistive load
100
50
30
250-VAC/30-VDC resistive load
Standard type
High-sensitivity type
DC resistive
load
1
0.5
0.3
DC inductive
load
AC inductive
load
cosφ=0.4
10
5
250-VAC/30 VDC inductive load
(cosφ=0.4/ L/R=7 ms)
3
0.1
0
3
5
10
30
100
250 500 1,000
0
1
2
3
4
5
6
7
8
9
10
23 30
40
50
60
70
80 85 90
Switching voltage (V)
Switching current (A)
Ambient temperature (°C)
Ambient Temperature vs.
Operating/Recovery Voltage
G6DS-1A
Ratio of rated voltage (%)
90
80
70
60
50
40
30
20
10
0
−60
−40
−20
Malfunctioning Shock
G6DS-1A
Energized
Not energized
Y
1000
800
X
600
400
200
0
Z
Note:
The maximum coil voltage is the maximum
voltage that can be applied to the relay coil.
max.
ave.
min.
Z'
max.
ave.
min.
0
20
40
60
80
100
X'
Y
Shock direction
X
X'
Z
Z'
Y'
Y'
Units: m/s
2
Coil terminals
Ambient temperature (°C)
Measurement conditions: Impose a shock in the
±X, ±Y,
and
±Z
directions three times each with the Relay energized to
check the shock values that cause the Relay to malfunction.
■
Approved Standards
•
The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog.
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 95°C
Model
G6DS-1A
Contact form
SPST-NO
Coil ratings
5 to 24 VDC
Contact ratings
5 A at 250 VAC (Resistive)
5 A at 30 VDC (Resistive)
G6DS-1A-H
5 A at 250 VAC (Resistive)
5 A at 30 VDC (Resistive)
80,000
Number of test operations
100,000
VDE (EN61810-1) (License No. B161)
Model
G6DS-1A
G6DS-1A-H
Contact form
SPST-NO
Coil ratings
5, 12, 24 VDC
Contact ratings
5 A, 250 VAC (cosφ=1.0)
5 A, 30 VDC (0 ms)
5 A, 250 VAC (cosφ=1.0)
5 A, 30 VDC (0 ms)
PCB Relay
G6DS
133
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
G6DS-1A/1A-H
Terminal Arrangement/
Internal Connections
(Bottom View)
21.3 max.
5.08 max.
20
Mounting Holes
(Bottom View)
10.16±0.1
2.54±0.1
(1.11)
(1.11)
5.08±0.1
(1.26)
(1.46)
(1.4)
2.54±0.1
0.3
0.3
0.3
0.3
0.6
Connecting Socket
P6DS-04P
5.55 max.
22.5 max.
Mounting Holes
(Bottom View)
17.78±0.05
12.7±0.05
2.54±0.05
0
6.1
−0.1
14.8 max.
(2.31)
Four, 1.1 dia.
(2.31)
0.3
2.54
10.16
5.08
0.6
3.65
Relay Pullout Tool
R99-01 for G6DS
The R99-01 for G6DS is a convenient tool to remove a G6DS Relay from a P6DS-04 Socket when sockets are mounted very closely together.
Packing
■
Stick packing
1 stick = 25 Relays
1 packing case = 20 sticks (500 Relays)
1 carton box = 6 packing cases (3,000 Relays)
134
PCB Relay
G6DS
2.54±0.05
(1.2)
3.3
0.8
12.5 max.
ur,
Fo dia.
1.1
Precautions
More than two relays can be closely mounted right side up as shown
in the following illustration. (This applies to the P6DS as well.)
5.08 mm
18.5 mm max.
Socket Mounting Height
Current flow:
5 A max.
More than two relays can be closely mounted upside down as shown
in the following illustration.
7.62 mm in the
upside-down
direction
When mounting the relay, insert it into the socket as vertically as pos-
sible so that the relay terminals contact securely with the contact pins
on the socket.
The P6DS is flux-resistive. Do not wash the P6DS with water.
Remove the relay from the socket before soldering the socket to a
PCB.
Disclaimer:
Current flow:
2 A max.
2.54 mm
Note:
The space between relays required for heat radiation may vary
with operating conditions. Contact your OMRON representative
for details.
All technical performance data applies to the product as such; spe-
cific conditions of individual applications are not considered. Always
check the suitability of the product for your intended purpose.
OMRON does not assume any responsibility or liability for noncom-
pliance herein, and we recommend prior technical clarification for
applications where requirements, loading, or ambient conditions dif-
fer from those applying to general electric applications. Any responsi-
bility for the application of the product remains with the customer
alone. THIS COMPONENT CAN NOT BE USED FOR AUTOMO-
TIVE APPLICATIONS.
PCB Relay
G6DS
135