EEWORLDEEWORLDEEWORLD

Part Number

Search

BK1/ABC-3-R

Description
FAST BLOW ELECTRIC FUSE, 3A, 250VAC, 125VDC, 100A (IR), INLINE/HOLDER, ROHS COMPLIANT
CategoryCircuit protection    Circuit protection   
File Size205KB,2 Pages
ManufacturerEaton
Environmental Compliance
Download Datasheet Parametric View All

BK1/ABC-3-R Overview

FAST BLOW ELECTRIC FUSE, 3A, 250VAC, 125VDC, 100A (IR), INLINE/HOLDER, ROHS COMPLIANT

BK1/ABC-3-R Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerEaton
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
Other featuresRATED BREAKING CAPACITY AT 125 VDC: 10000 A
Fusing characteristicsFAST
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal19 J
Manufacturer's serial numberABC
Installation featuresINLINE/HOLDER
method of packingBOX
physical size6.35mm x 31.75mm
Rated breaking capacity100 A
Rated current3 A
Rated voltage (AC)250 V
Rated voltage (DC)125 V
GuidelineCSA; UL
surface mountNO
Terminal shapeEND CAP
1
4
” x 1
1
4
” Glass Tube Fuses
ABC Series, Fast-Acting, Ceramic Tube
Description
• Fast-acting, ceramic tube
• Optional axial leads available
1
4
” x 1
1
4
” (6.4 x 31.7mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
4 Hours Minimum
135%
60 Minutes maximum
200%
120 Seconds Maximum
Dimensions - mm
Drawing Not to Scale
Agency Information
• UL Listed Guide JDYX & File E19180
• UL Recognition Guide JDYX2 & File E19180
• CSA Certification: Class No: 1422-01 & 1422-30,
File 53787
Environmental Data
• Shock:
1
4
A - 30A – MIL-STD-202, Method 213,
Test Condition J
• Vibration:
1
4
A - 30A – MIL-STD-202, Method 204,
Test Condition C (Except 5g, 500Hz)
Ordering
• Specify packaging, product and option code
Voltage
Ratings
Vac
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Vdc
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
Vac Interrupting
Ratings* (amps)
250
125
35
10,000
35
10,000
35
10,000
35
10,000
100
10,000
100
10,000
100
10,000
100
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
750
10,000
750
10,000
400
1000
400
1000
200
1000
200
1000
* Interrupting ratings measured at 70% - 80% power factor on AC. The interrupting ratings for 18A and 20A were measured at 85% - 95% power factor on AC. The
interrupting ratings for 25A and 30A were measured at 89% power factor on AC.
** Typical DC cold resistance measured at <10% of rated current.
† Typical melting I2t measured at listed interrupting rating and rated voltage.
‡ Typical voltage drop measured at 25°C±3°C ambient temperature at rated current.
‡‡ CSA approvals for 25A and 30A are at 125Vac - IR 1000A and 125Vdc - IR 400A (IR 1000A at 75Vdc)
Part
Number
ABC-
1
4
-R
ABC-
1
2
-R
ABC-
3
4
-R
ABC-1-R
ABC-1-
1
2
-R
ABC-2-R
ABC-2-
1
2
-R
ABC-3-R
ABC-4-R
ABC-5-R
ABC-6-R
ABC-7-R
ABC-8-R
ABC-10-R
ABC-12-R
ABC-15-R
ABC-18-R
ABC-20-R
ABC-25-R
ABC-30-R
Vdc Interrupting
Ratings (amps)
125
75
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
400
1000
400
1000
Specifications
Typical
DC Cold
Resistance (Ω)**
2.950
0.587
0.300
0.1950
0.131
0.0890
0.061
0.047
0.031
0.026
0.021
0.016
0.014
0.011
0.0068
0.00553
0.00465
0.00366
0.0028
0.002225
Typical
Pre-Arc
I
2
t AC
0.0020
0.0390
0.1450
0.4310
1.1630
2.1670
4.4670
6.55
22.28
32.83
58
109.33
116.5
208.8
133.3
200.2
400
550.8
839.3
1429
Typical
Voltage
Drop (V)
0.35
0.41
0.32
0.3
0.28
0.31
0.23
0.14
0.17
0.22
0.19
0.17
0.19
0.15
0.1
0.1
0.1
0.1
0.09
0.09
Agency Approvals
UL UR CSA
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
‡‡
X X
‡‡
0613
BU-SB13635
Page 1 of 2
Data Sheet 2000
PCB
[i=s]This post was last edited by 13815346101 on 2015-10-8 11:55[/i] I just drew a small board, and there are some shortcomings. I would like to invite your comments....
13815346101 PCB Design
TI's AWR1243 radar learning record
1. Maximum distance2. Maximum distance3. Distance resolution4. Maximum speed5. Speed resolution6. Maximum angle range7. Angular resolutionSingle transmitting antennaMultiple antennas Transmission situ...
Jacktang Wireless Connectivity
C51 serial communication is displayed on LCD1602
How can I convert the data sent from SBUF to temp and display it on LCD1602? I have been thinking about it for two days, but I really don't know how to do it. Please help me! My LCD write string state...
寒雪剑91 MCU
How to minimize when calling wmplayer?
I am now developing a wince program to directly call Media Player to play audio through SHELLEXECUTEINFO. The main code is as follows: SHELLEXECUTEINFO sei; ZeroMemory(&sei,sizeof(sei)); sei.cbSize = ...
jimyang2008 Embedded System
Design of low power WiFi wireless sensor network
[size=2]Do you know what low-power Wi-Fi wireless sensor networks are? Do you know how to design low-power Wi-Fi wireless sensor networks? Do you know what low-power Wi-Fi wireless sensor network deve...
zigbeeMM Embedded System
Help max30001 FIFO ECG
Has anyone used MAX30001? How to process the ECG data read from FIFO?...
dz_2019 Medical Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1720  1851  2561  68  1643  35  38  52  2  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号