Radial Leaded PPTC
FRH Series
FEATURES
•
Low hold current, Solid state Radial-leaded product ideal for
RoHS
ü
AGENCY RECOGNITION
•UL (E211981)
•C-UL (E211981)
•TÜV (R50004084)
up to 60V/250V/600V
•
Application: Telecommunication and Data transmitting
•
Operation Current: 0.08A ~ 0.18A
•
Maximum Voltage: 60V/250V/600V
•
Temperature Range: -40°C to 85°C
ELECTRICAL CHARACTERISTICS (23°C)
Part Number
FRH080-250UF
FRH080-250F
FRH110-250UF
FRH110-250F
FRH120-250UF
FRH120-250F
FRH145-250UF
FRH145-250F
FRH180-250UF
FRH180-250F
FRH150-600F
FRH160-600F
Hold
Current
I
H
, A
0.08
0.08
0.11
0.11
0.12
0.12
0.15
0.15
0.18
0.18
0.15
0.16
Trip
Current
I
T
, A
0.16
0.16
0.22
0.22
0.24
0.24
0.29
0.29
0.65
0.65
0.30
0.32
Max. Time Maximum
to Trip
Current
A
0.35
0.35
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.0
1.0
Sec
4.0
4.0
2.0
2.0
2.0
2.0
2.5
2.5
10.0
11.0
5.0
7.0
I
MAX
, A
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
10.0
10.0
3.0
3.0
Max. Oper.
Voltage
V
MAX
, V
DC
60
60
60
60
60
60
60
60
60
60
60
60
Max. Int.
Voltage
V
I-MAX
, V
250
250
250
250
250
250
250
250
250
250
600
600
Resistance Tolerance
R
MIN
R1
MAX
OHMS
14.0
14.0
5.0
5.0
6.0
4.0
3.5
3.0
0.8
0.8
6.0
4.0
OHMS
33.0
33.0
16.0
16.0
16.0
16.0
12.0
12.0
4.0
4.0
22.0
18.0
I
H
=Hold current-maximum current at which the device will not trip at 23°C still air.
I
T
=Trip current-maximum current at which the device will always trip at 23°C still air.
V
MAX
=Maximum voltage device can withstand without damage at its rated current.
V
I-MAX
=Maximum interrupt voltage device can withstand for short period of time. (Not for long term.)
I
MAX
=Maximum fault current device can withstand without damage at rated voltage (V
MAX
).
Pd=Typical power dissipated from device when in the tripped state in 23°C still air environment.
R
MIN
=Minimum device resistance at 23°C.
R1
MAX
=Maximum device resistance at 23°C, 1 hour after tripping.
Physical specifications:
Lead material: FRH080-250~FRH180-250 Tin plated copper, 22 AWG.
FRH150-600~FRH160-600 Tin plated copper, 22 AWG.
Soldering characteristics: MIL-STD-202, Method 208E.
Insulating coating: Flame retardant epoxy, meet UL-94V-0 requirement.
Figure 1
FRH PRODUCT DIMENSIONS (MILLIMETERS)
NOTE: All FRH products are designed to assist equipment to pass ITU,
UL1950 or GR1089 specification.
Part
Number
FRH080-250UF
FRH080-250F
FRH110-250UF
FRH110-250F
FRH120-250UF
FRH120-250F
FRH145-250UF
FRH145-250F
FRH180-250UF
FRH180-250F
FRH150-600F
FRH160-600F
A
4.8
5.3
5.3
5.8
6.0
6.5
6.0
6.5
10.4
10.9
13.5
16.0
B
9.1
9.6
9.4
9.9
10.0
11.0
10.0
11.0
12.6
13.6
12.6
12.6
C
5
5
5
5
5
5
5
5
5
5
5
5
D
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
E
Lead Size: 22AWG (0.65mm)
Maximum Maximum Typical Minimum Maximum
3.8
4.6
3.8
4.6
3.8
4.6
3.8
4.6
3.8
4.6
6
6
Figure 2
Lead Size: 22AWG (0.65mm)
CAUTION: FRH devices are not intended for continous use of Line Voltage such as 120 VAC`600VAC and above.
RFE International
• Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail Sales@rfeinc.com
C5EB08
REV 2007.03.1
Radial Leaded PPTC
FRH Series
THERMAL DERATING CURVE
RoHS
ü
Thermal Derating Curve - FRH Series
Percent of Rated Hold and Trip
Current
200%
150%
100%
50%
0%
-40
-20
0
20
40
60
80
Ambient Temperature (C)
TYPICAL TIME-TO-TRIP AT 23°C
1000
100
Time-to-trip (S)
10
1
0.1
G
E
F
D
C
B
A
A=
B=
C=
D=
E=
F=
G=
FRH080(U)-250
FRH110(U)-250
FRH120(U)-250
FRH145(U)-250
FRH180(U)-250
FRH150-600
FRH160-600
0.01
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
2.6
2.8
3
Fault current (A )
CAUTION: FRH devices are not intended for continous use of Line Voltage such as 120 VAC`600VAC and above.
NOTE: All Specification subject to change without notice.
RFE International
• Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail Sales@rfeinc.com
C5EB08
REV 2007.03.1