EEWORLDEEWORLDEEWORLD

Part Number

Search

KL412DKXXA122N024

Description
Rocker Switch, DPST, Latched, 0.02A, 12VDC, Solder/quick Connect Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size452KB,9 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

KL412DKXXA122N024 Overview

Rocker Switch, DPST, Latched, 0.02A, 12VDC, Solder/quick Connect Terminal, Rocker Actuator, Panel Mount

KL412DKXXA122N024 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerAPEM
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeROCKER
body width24 mm
body height35.5 mm
Body length or diameter46.5 mm
Contact (AC) maximum rated R load.02A@12VAC
Maximum contact current (AC)0.02 A
Maximum contact current (DC)0.02 A
Contact (DC) maximum rated R load.02A@12VDC
Maximum contact voltage (AC)12 V
Maximum contact voltage (DC)12 V
Electrical life150000 Cycle(s)
JESD-609 codee4
Manufacturer's serial numberKL
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
method of packingBULK
sealIP68
surface mountNO
Switch actionLATCHED
switch functionDPST
Switch typeROCKER SWITCH
Terminal surfaceSilver (Ag)
Termination typeSOLDER/QUICK CONNECT
KL series
Locking rocker switches
Distinctive features
Unlocking actuator
Protection frames
Unlocking actuator
Each KL rocker switch includes an unlocking actuator.
This actuator must be pressed to activate the protected function of the rocker.
Moreover, two frames protect the unlocking actuator from untimely activation.
This intuitive and secured ergonomics is patented by APEM.
2 position versions
(electrical functions 1, 5 and 6)
Press unlocking actuator
to reach the protected position
Press opposite part of actuator
to leave the protected position
Á
Á
3 position versions
(electrical functions 7, 8, 9 4, 4-1R)
Press unlocking actuator
to reach the protected position
Press opposite part of actuator
to leave the protected position
Á
Á
Á
12
www.apem.com
APEM
An iron wire is connected to the metal shell for grounding, but the power supply is a two-phase plug. Is it dangerous?
An iron wire is connected to the metal shell for grounding, but the power supply is a two-phase plug. Is it dangerous?...
冰魄3009 Analog electronics
It turns out that simply comparing the sizes of two numbers in FPGA is so different?
Two constants are defined parameter signed [15:0] hight_threshold = 600;parameter signed [15:0] low_threshold = -600; Compare with a register reg signed [15:0]data, When the data is -90, the following...
littleshrimp FPGA/CPLD
How to modify the drive letter in the FILE_OJBECT structure? Not much, please have a look! !
PVOID pFileNameBuffer = NULL; // Object header = pFileObject->DeviceObject + 0x18 POBJECT_HEADER pObjectHeader = OBJECT_TO_OBJECT_HEADER(pFileObject->DeviceObject); // _OBJECT_HEADER_NAME_INFO in _OBJ...
readeagle Embedded System
Problems with M4 timer count capture mode
I am a novice and have never written the timer count capture mode of TM4C123GH6PM. I would like to ask someone who has written it how to write it. I would be very grateful....
jacbpan Microcontroller MCU
A new and practical IGBT driving circuit
Abstract: Based on the analysis of IGBT driving conditions, several common IGBT driving circuits are introduced, and their respective advantages and disadvantages are given. A simple and practical new...
eeleader Industrial Control Electronics
Red Hat Linux Commands
redhat linux command encyclopedia 2009-05-09 18:47 1. Startup, shutdown, login, logout related commands login login logout logout exit logout shutdown halt system halt halt system reboot restart power...
woshishuiaa Linux and Android

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2636  1320  939  2337  1673  54  27  19  48  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号