EEWORLDEEWORLDEEWORLD

Part Number

Search

21-002.25-173PTLHT

Description
INTERCONNECTION DEVICE
CategoryThe connector    The connector   
File Size240KB,2 Pages
ManufacturerAries Electronics
Download Datasheet Parametric View All

21-002.25-173PTLHT Overview

INTERCONNECTION DEVICE

21-002.25-173PTLHT Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
Series 171 thru 173
Flat Pin Staked Flex Jumpers
FEATURES:
• Aries Flat Pin Staked Flex Jumpers combine thin, flexible, solid Copper
conductors embedded between layers of tough, flexible, flame-
retardant insulation.
• Consult factory for cable lengths under 2.000 [50.80].
• See DataSheet
11019
for 90° Pin Staked Flex Jumpers.
• For RoHS applications for Lead-Free Soldering use HT Cable.
GENERAL SPECIFICATIONS:
• Standard cable insulation is white UL VW-1, Style 2643 flame retardant
Polyester (Mylar) adhesive.
• High temperature flame retardant cable insulation is Polyimide
(Kapton) insulation with acrylic adhesive.
• Cable conductors are solid Copper with a cross-sectional area equiva-
lent to that of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
• Female and male “crimp-on” pins are spring-tempered Copper
Alloy 510.
• Female and male pin plating:
T
= 100μ” [2.54μm] min. Matte Tin per ASTM-B545-97 over 50μ” Min
Nickel per SAE-AMS-QQ-N-290
TL
= 100μ” [2.54μm] min. 93/7 Tin/Lead per SAE-AMS-P-81728 over
50μ” [1.27μm] min. Nickel per SAE-AMS-QQ-N-290.
• Cable current rating=3 Amps.
• Cable voltage rating=300 Volts.
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
=4000 Volts/mil, minimum (high temp.).
• Cable insulation resistance=1000 MOhms minimum (standard)
=100,000 MOhms (high temp.).
• Operating temperature=-67 to 257°F [-55 to 105°C].
• Female housing accepts leads .024-.030 [.61-.76] square, .150 [3.81]
long minimum.
MOUNTING CONSIDERATIONS:
•Suggested PCB hole size=.032 ± .002 [.81 ± .05] dia.
Note: Aries specializes in custom design and production. In addition to the
standard products shown on this page, special materials, platings, sizes, and
configurations can be furnished, depending on quantities. Aries reserves the
right to change product specifications without notice.
ORDERING INFORMATION
XX-XXXXX-17XXXXXX
Optional Suffix:
HT = High
temp. cable
insulation
Optional Suffix:
TL = Tin/Lead
Plating
Optional Suffix:
P= polarization
stripe along one
edge of cable**
No. of conductors
(4 thru 40)
Kapton is a registered trademark of DuPont
Cable length: “L” in inches:
Min. Cable Length = 2.00” (-002-)
2” = -002-
2.5” = -002.5-
2.25” = -002.25-
2.125” = -002.125-
Jumper series:
171: male Tin both ends
172: male Tin/female Tin
173: female Tin both ends
CABLE DETAIL
MALE CONTACT DETAIL
** Aries reserves the right to
ship with or without a polariza-
tion stripe unless otherwise
specified by the customer
http://www.arieselec.com • info@arieselec.com
Bristol, PA USA
TEL: (215) 781-9956
FAX: (215) 781-9845
abc
11005
REV. J
Page 1 of 2
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
I have a small question about FHSS of the physical layer of 802.11.
I've been looking at the FHSS (Frequency Hopping Spread Spectrum) of the physical layer of 802.11 these days. It works at 2.4GHz and uses 79 channels. The bandwidth of each channel is 1MHZ. What does ...
yil_zy Embedded System
Is the chip industry about to change? Nvidia launches its first CPU, which achieves ten times the performance of x86
On the evening of April 12, NVIDIA's GTC 2021 conference started online. Perhaps because of long-term remote work without going out, people were surprised to see that Mr. Huang, who was giving a keyno...
eric_wang Talking
Importance and necessity of wiring harness tester in new energy vehicle wiring harness production
The development of the new energy vehicle industry has brought new development and hope to the automotive wiring harness, and the development of the automotive wiring harness has also brought new oppo...
Agitek电子 Automotive Electronics
Can radar ranging sensors be used in this environment?
This is a closed hole with a depth of 50 meters and a diameter of about 60 mm. I want to use radar ranging to transmit and receive at the hole mouth to measure the hole depth. I don't know if it is fe...
wanghongyu Integrated technical exchanges
Help! Chinese and English parallel papers
I need help with a 5000-word paper about MSP430 for traffic light control, with Chinese and English translations. Thank you!...
arafat MCU
Zigbee master-slave device switching, please help!
I want to implement a function like this: in a zigbee network, there is a master device, a backup master device, and the others are slave devices. When the master device fails, the network automatical...
nwjane RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1100  1808  456  2739  687  23  37  10  56  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号