Rotary Coded Switch, 5 Positions, Decimal, Latched, 20A, 28VDC, Quick Connect Terminal, Spindle Actuator, Panel Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size111KB,2 Pages
ManufacturerBULGIN
Websitehttp://www.bulgin.co.uk/
Environmental Compliance
Download Datasheet Parametric View All

H9501NA Overview

Rotary Coded Switch, 5 Positions, Decimal, Latched, 20A, 28VDC, Quick Connect Terminal, Spindle Actuator, Panel Mount, ROHS COMPLIANT

H9501NA Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerBULGIN
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeSPINDLE
body width18.5 mm
body height32 mm
Body length or diameter32.3 mm
Contact (AC) maximum rated R load16A@250VAC
Maximum contact current (AC)16 A
Maximum contact current (DC)20 A
Contact (DC) maximum rated R load20A@28VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)28 V
Manufacturer's serial number9100
Installation featuresPANEL MOUNT
Number of positions5
Number of switching segments1
surface mountNO
Switch actionLATCHED
switch functionDECIMAL
Switch typeROTARY CODED SWITCH
Termination typeQUICK CONNECT
9100 Rotary Switches
16A 250Vac
2 to 6 way rotary switch
Ratings up to 16A,
250V ac; 20A, 28V dc
Pairs of single pole
change over contacts
In house test
16(4)A 250Vac T125
16A 400Vac T125
8(8)A 250Vac T125 5E4 (50,000 Operations)
UL CSA 20A Non Ind 277Vac, 250Vac 2hp, 125Vac 1hp
UL85°C, file no. E45221, CSA file no. LR10990
30A 12V dc
RoHS compliant
9100 switches are highly versatile with up to 6 positions at 30° intervals and
6 terminals per switch. For more complex switching (7 positions & over),
contact the factory. Two switches may be stacked to give up to 12 terminal
switching.
3mm contact gap.
Technical data on pages 4 & 5.
Wide choice of
switching circuits
Can be stacked together
RoHS
C 9 5 01 D A Stop at 120˚
ORDER FORMAT
TERMINAL
C
2
9.2
TERMINAL SERIES POSITIONS CIRCUIT SPINDLE BODY OPTIONS
CODE
CODE
CODE
CODE
CODE CODE
SERIES
POSITION
CIRCUIT
9100 switches offer almost infinite
switching options
For this reason it is impractical to show all the
options available.
SPINDLE
A
ø6.0
4.5
A/F
26.0
Switching
positions
B
The table below gives an example of a
5 position switching sequence:
6.3 x 0.8
ø6.0
4.5
A/F
22.0
OFF, 1, 1+2, 1+2+3, 1+2+3+4
C
3
Switching
positions
1
A
2
3
B
Off
Pos 1 Pos 2 Pos 3 Pos 4 Pos 5
ø6.0
4.5
A/F
10.8
D
ø6.05
4.65
A/F 12.2
M
ø6.0
15˚
4
5 A.65
/F
4
9
H
Switching
positions
4
12.2
The code
for your chosen circuit will be
allocated by our technicians.
Please contact the factory for details.
N
ø6.0
4.5
A/F
20.0
9.2
Use the blank table to plan your switching
up to 6 positions.
P
4.5
A/F
ø6.0
23.0
5
4.8 x 0.8
For approval information on H terminals,
contact the factory.
1
A
2
Switching
positions
Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6
R
4.5
ø6.0
A/F 12.2 20.1
for 2 gang switching
S
5
4. /F
A
˚
45
ø6.0
10.8
6
Simple circuits may not use all terminals.
Unnecessary terminals may be omitted.
Switching
positions
3
B
4
L
supplied without spindle
64
ARCOLECTRIC CORPORATION
31-315 Plantation Drive, Thousand Palms, CA 92276 Tel: 760-343-3650 Fax: 760-343-3651 email: info@arcolectric.com
Intel plans to release nine Merom processors in the fourth quarter
Intel plans to release nine Merom processors in the fourth quarter . According to a report by The Inquirer, a foreign website, Intel plans to release nine dual-core processors using the Merom core in ...
hongshao RF/Wirelessly
Ask questions + invite everyone to analyze a relay control circuit
[backcolor=white]As shown in the figure, two Darlington tubes control one coil, what is the role of diode D1 (surge protection tr3), D2? [/backcolor] eeworldpostqq...
jemima Analog electronics
The competition is over, what are your thoughts?
The national competition is over. Come in and talk about your ideas! It seems that this place is getting quiet! Let me talk about myself first. I learned a lot in this competition, and I also had a lo...
open82977352 MCU
What are the indicators of high-performance AC servo?
What indicators can be used to measure a high-performance AC servo? For example, speed regulation range, steady speed accuracy, response frequency, etc. Also, what is the specific value of these indic...
eeleader Industrial Control Electronics
Excerpts on the principle and application of open-drain stage
In circuit design, we often encounter the concepts of open drain and open collector. Although I knew the basic usage when I was in school and never encountered any problems in design, a colleague aske...
babyjiejie Power technology
Dear friends, let's collect some good embedded forums (ARM, DSP, FPGA, MCU are all OK)
I'll start withthe eeworld hardware embedded section. Needless to say, I grew up here.www.armce.com/bbs - this is dedicated to wince, I think it's not bad, there are a lot of original and non-original...
spirit_only ARM Technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 888  1670  2391  2096  887  18  34  49  43  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号