Electric Fuse, Fast Blow, 25A, 17000VAC, 14000A (IR), Inline/holder
CategoryCircuit protection    Circuit protection   
File Size980KB,13 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

BBU17-25K Online Shopping

Suppliers Part Number Price MOQ In stock  
BBU17-25K - - View Buy Now

BBU17-25K Overview

Electric Fuse, Fast Blow, 25A, 17000VAC, 14000A (IR), Inline/holder

BBU17-25K Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
Fusing characteristicsFAST
body height19.08 mm
Body length or diameter1.24 mm
Built-in featuresINDICATOR
Circuit protection typeELECTRIC FUSE
Manufacturer's serial numberBBU
Installation featuresINLINE/HOLDER
physical size1.24mm x 19.08mm
Rated breaking capacity14000 A
Rated current25 A
Rated voltage (AC)17000 V
surface mountNO
Terminal shapeEND CAP
Bussmann
®
Boric Acid Fuses
Medium Voltage
BBU
General
• The BBU power fuse is a Boric Acid, expulsion style
fuse unit.
• Provides a low initial cost alternative to refillable fuses
in indoor applications.
• Utilizes calibrated silver elements, boric acid for its inter-
rupting media, and a spring & rod mechanism.
• The housing is a fiberglass reinforced resin tube with plated
copper contacts.
• Available in 3 maximum voltage classes:
17kV, 27kV & 38kV
• Available in 3 speed variations:
E (Standard) SE (Slow E) & K (Fast)
• Visual Indicating with use of end fittings.
• End Fittings:
• End fittings are required to complete the electrical
connection between the fuse unit and the live parts
and mounting.
• The indoor fittings accept a Muffler attachment to
limit noise and contamination to indoor equipment.
The open fuse indicator located on the top end fit-
ting provides visual indication on a faulted fuse unit.
Catalog Symbol:
BBU
Medium Voltage Expulsion Fuse
Fuse Class:
E (Standard), SE (Slow E) & K (Fast)
Voltage Rating:
17kV, 27kV & 38kV
Interrupting Ratings:
17kV - 14kA
27kV - 12.5kA
38kV - 10kA
Boric Acid, expulsion style fuses meet:
• ANSI C37.40 – Service Conditions and Definitions
• ANSI C37.41 – Power Fuse Design and Testing
• ANSI C37.42 – Distribution Fuse Ratings and Specifications
• ANSI C37.46 – Power Fuse Ratings and Specifications
• ANSI C37.48 – Power Fuse Application, Operations and
Maintenance
Applications
The BBU Boric Acid fuse provides effective protection for cir-
cuits and equipment which operate on voltage systems up to
34,500V. Typical usage is on industrial distribution systems for:
• Power Transformers
• Feeder Circuits
• Distribution Transformers
• Metal Enclosed Switchgear
• Pad Mounted Switches
5-30-02
SB02199
Form No. BBU
Page 1 of 13
Data Sheet: 1123
How to get a mobile phone number in Open at
I use open at to write a program to record the incoming phone numbers and call records.... How can I get the other party's phone number and call time? ? ? ?...
chenzhiyu Embedded System
WinCE 6.0 label Chinese line break problem
In WINCE 6.0 system, I run a C# application written in .NET. I found that when the words of the Label control need to wrap, English can wrap automatically, but Chinese can only display one line of wor...
jasonliu Embedded System
Review summary: Free review of Pingtouge scenario-based Bluetooth Mesh gateway development kit
Activity details: [Free evaluation of Pingtouge scenario-based Bluetooth Mesh gateway development kit]Updated to 2021-12-01 Evaluation report summary:@damiaa [Free Trial of the Pingtouge Bluetooth Mes...
EEWORLD社区 Special Edition for Assessment Centres
【TI's First Low Power Design Competition】07611128 Host Computer Part
Ever since sister Maylove told me that the competition was postponed to January 5th, I suddenly felt lazy. Then I spent a good night writing the dsp test program and report by myself. Then I had nothi...
07611128 Microcontroller MCU
MOSFET capacitor
Is there a way to verify the difference between the capacitance coss and cotr, coer of the mosfet, and which one is better, or any ideas are also fine....
solitary Discrete Device
5G small base station construction technology article sharing
Since 5G networks operate at higher frequency bands, the penetration capability of traditional macro base stations is weakened, and small base stations can be used to make up for the insufficient cove...
alan000345 RF/Wirelessly

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 951  2006  2025  253  1765  20  41  6  36  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号