TITLE
SPECIFICATIONS
-Designed to meet UL1950/IEC950 with
supplementary isolation for a working voltage < = 250 VRMS
-Operating temperature: -40° To +85°C
-Meets Telcordia GR1089,surge 1 of table 4-3 (5.0KV,2x10us)
20 pulses at 10 second intervals with alternate polarities.
1.INDUCTANCE: 0.1 VRMS, 10 kHz, 0 - 100 mADC
1-5 TIE 4&2 = 2.82 TO 3.18 mH (3.0mH +/- 6%)
2. TURNS RATIO: 1-5 (TIE 4&2) : 9-7 = 5.45 : 1 ± 1%
3. INDUCTANCE RATIO: 0.1VRMS, 10 kHz
1-5 (TIE 4&2) = 5.4 : 1 ± 1%
4. LEAKAGE INDUCTANCE: 0.1 VRMS, 100 kHz
1-5 TIE 4&2, SHORT (9-7) = 15µH Max
5. DC RESISTANCE: OHMS Max
1-5 (tie 4 &2) =4.0
9-7 = 0.35
6. DIELECTRIC STRENGTH:
2050 VAC, 1 SECOND (ALT. 2900 VDC, 1 SECOND)
Primary to Secondary-Safety Critical
720 VAC, 1 Minute (ALT. 1000 VDC, 1 Second)
Terminal #1 to Terminal #2
7. LONGITUDINAL BALANCE: 20 kHz TO 250 kHz = 55 dB MIN
8. FREQUENCY RESPONSE:
17 kHz TO 600 kHz (ref.100kHz)= +/- .5dB
9. INSERTION LOSS: 100 kHz, = .55dB Max
10. IWC: : 100 kHz, 0.1 Vrms, (1,4,2,5) to (9-7) = 120 pF MAX
11. THD:
5 kHz, 2.0 Vrms = -82dB Max
5kHz,4.0VRMS = -76dB Max
TRANSFORMER
AGENCY APPROVAL PENDING
.670 ±.010
(17.02)
A
.560 MAX
(14.22)
5
6
SCHOTT
39583
YYWW
1
10
.098
(2.5
B
.500 MAX
(12.70)
.008
(0.2)
.606 ± .006
(15.39)
.09
(
NOTE:
COPLANARITY < .004 (0.10)
1
4
2
LINE
5
TOLERANCE
INCHES-DECIMA
MILLIMETERS (m
1000 Parkers Lake Road, Wayzata, MN 55391, (952) 475-1173, www.schottcorp.com