EEWORLDEEWORLDEEWORLD

Part Number

Search

BK/AGC-7-1/2B

Description
Electric Fuse, Fast Blow, 7.5A, 250VAC, 200A (IR), Inline/holder
CategoryCircuit protection    Circuit protection   
File Size306KB,5 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

BK/AGC-7-1/2B Overview

Electric Fuse, Fast Blow, 7.5A, 250VAC, 200A (IR), Inline/holder

BK/AGC-7-1/2B Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerCooper Industries
Reach Compliance Codeunknown
Fusing characteristicsFAST
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
Manufacturer's serial numberAGC
Installation featuresINLINE/HOLDER
method of packingBOX
physical size6.35mm x 31.75mm
Rated breaking capacity200 A
Rated current7.5 A
Rated voltage (AC)250 V
GuidelineCSA; UL
surface mountNO
Terminal surfaceNickel (Ni)
Terminal shapeEND CAP
1/4" x 1-1/4" Fuses
AGC Series, Fast Acting, Glass Tube
Description
• Fast-acting, glass tube
• Optional axial leads available
• 1/4 x 1-1/4 (6.3mm x 32mm) physical size
• Glass tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
None
135%
60 Minutes Maximum
200%
120 Seconds Maximum
RoHS
2002/95/EC
Dimensions
(
mm
in
)
Drawing Not to Scale
Agency Information
• UL Listed Card: AGC 1/500-10
• UL Recognition Card: AGC 11-45
• CSA Component Acceptance Card (Class No. 1422 30)
• CSA Certification Card (Class No. 1422 01)
Environmental Data
• Shock: 1/100A thru 3/4A – MIL-STD-202,
Method 213, Test Condition I; 1A thru 30A –
MIL-STD-202, Method 207, (HI Shock)
• Vibration: 1/100A thru 30A – MIL-STD-202,
Method 204, Test Condition A (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
Product Code
AGC-1/20
AGC-1/16
AGC-1/10
AGC-1/8
AGC-3/16
AGC-2/10
AGC-1/4
AGC-3/10
AGC-3/8
AGC-1/2
AGC-3/4
AGC-1
AGC-1-1/4
AGC-1-1/2
AGC-2
AGC-2-1/4
AGC-2-1/2
AGC-3
AGC-4
AGC-5
AGC-6
AGC-7
AGC-7-1/2
AGC-8
AGC-9
AGC-10
AGC-12
AGC-14
AGC-15
AGC-20
AGC-25
AGC-30
AGC-35
AGC-40
Voltage
Rating
AC
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
32V
32V
32V
32V
32V
32V
32V
32V
250V
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
100A
100A
100A
100A
100A
100A
200A
200A
200A
200A
200A
200A
200A
200A
-
-
-
-
-
-
-
-
AC Interrupting
Rating
125V
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
-
-
-
-
-
-
-
-
SPECIFICATIONS
32V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1000A
1000A
1000A
1000A
1000A
1000A
70A
80A
Typical DC Cold
Resistance**
(ohms)
4.500
29.000
12.565
6.800
4.900
3.360
2.300
1.670
1.203
0.615
0.312
0.190
0.145
0.115
0.078
0.067
0.057
0.045
0.030
0.024
0.020
0.017
0.0146
0.014
0.012
0.008
0.0070
0.0062
0.006
0.004
0.003
0.002
0.0014
0.0019
Typical
Melting I
2
t†
AC
0.00773
0.000181
0.000787
0.00131
0.00637
0.00435
0.0148
0.0208
0.0321
0.269
0.815
1.615
0.018
0.0149
0.00509
0.00588
0.00879
0.0167
0.0305
0.045
0.071
0.105
-
0.152
0.21
0.492
-
-
0.566
1.438
2.109
3.807
-
-
Typical
Voltage
Drop‡
0.67
10.41
6.00
4.67
4.12
4.51
0.89
2.88
4.59
0.59
0.37
0.31
0.35
0.27
0.28
0.26
0.31
0.25
0.22
0.23
0.23
0.23
-
0.19
0.18
0.20
-
-
0.14
0.12
0.11
0.12
-
-
** DC Cold Resistance (Measured at
≤10%
of rated current)
† Typical Melting I
2
t (A
2
Sec) (I
2
t was measured at listed interrupting rating and rated voltage.)
‡ Typical Voltage Drop (Voltage drop was measured at 25°C ambient temperature at rated current)
WINCE about register value printing
I've been testing SDHC under WINCE recently, and added some RETAILMSG/DEBUGMSG print information. It turns out that the return value from the oscilloscope is different from the value in the register S...
jw_1001 Embedded System
【MicroPython】Show off the board, start learning python
Yesterday I found that the microusb of the board had problems, so I re-soldered it (borrowed one) I want to start learning Python. I remember that I first saw Python in high school. At that time, I us...
ihalin MicroPython Open Source section
Benefits of Digital Power Management
New generations of ICs require lower supply voltages, often with multiple voltages for a single device, which must be applied to the device in the correct sequence. These very low voltages to the IC m...
zbz0529 Power technology
Why can't the Quartus 12.1 version of the software generate simulation files?
I just started using 12.1, and the fft ip core failed to generate a modelsim simulation file (.vo file). There is no detailed error pop-up window. I don't know what the problem is. Has anyone encounte...
zhenpeng25 FPGA/CPLD
Please help analyze the schematic diagram of simple household appliance circuit, thank you
[i=s] This post was last edited by piaoyiliu03 on 2015-9-15 21:23 [/i] First: Is this a full-wave rectifier circuit or a half-wave rectifier circuit? What are the functions of D1 and D2? (I personally...
piaoyiliu03 Analog electronics
What does this error mean after running ccs5.5?
What does this error mean after running ccs5.5? Is it a configuration problem or a data storage problem? Is there any expert who can solve it? Thanks! eeworldpostqq...
LIUKY Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1064  2045  564  195  1737  22  42  12  4  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号