EEWORLDEEWORLDEEWORLD

Part Number

Search

LS1301-9ERDDTB1

Description
AC-DC Regulated Power Supply Module, 1 Output, 100W, METAL, CASE S02, MODULE
CategoryPower/power management    The power supply circuit   
File Size439KB,33 Pages
ManufacturerBel
Websitehttp://www.belfuse.com
Download Datasheet Parametric View All

LS1301-9ERDDTB1 Overview

AC-DC Regulated Power Supply Module, 1 Output, 100W, METAL, CASE S02, MODULE

LS1301-9ERDDTB1 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerBel
package instructionMETAL, CASE S02, MODULE
Reach Compliance Codeunknown
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage264 V
Minimum input voltage85 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Maximum load regulation0.208%
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-40 °C
Maximum output voltage13.2 V
Minimum output voltage2 V
Nominal output voltage12 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
Temperature levelOTHER
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output100 W
Fine-tuning/adjustable outputYES
S Series Data Sheet
100 Watt AC-DC and DC-DC Converters
Features
Input voltage ranges from 8 to 385 VDC and 85 to 264 VAC, 47-440 Hz
1or 2 isolated outputs up to 48 VDC
Class I equipment
RoHS lead solder exemption compliant
Extremely-wide input voltage range
Input over- and undervoltage lockout
Efficient input filter and built-in surge and transient
suppression circuitry
Outputs: SELV, no-load, and short-circuit proof
No derating over entire operating temperature range
111
4.4"
3U
60
2.4"
12 TE
168
6.6"
PCBs coated with protective lacquer
Very high reliability
Safety according to IEC/EN 60950
Description
The S Series AC-DC and DC-DC converters represents a broad
and flexible range of power supplies for use in advanced
electronic systems. Features include high efficiency, high
reliability, low output voltage noise and excellent dynamic
response to load/line changes. LS models can be powered by
DC or AC with a wide-input frequency range (without PFC).
The converter inputs are protected against surges and
transients. An input over- and undervoltage lockout circuitry
disables the outputs if the input voltage is outside of the
specified range. Certain types include an inrush current limiter
preventing circuit breakers and fuses from tripping at switch-on.
All outputs are open- and short-circuit proof and are protected
against overvoltages by means of built-in suppressor diodes.
The outputs can be inhibited by a logic signal applied to pin 18
(i). If the inhibit function is not used, pin 18 must be connected
with pin 14 to enable the outputs.
LED indicators display the status of the converter and allow for
visual monitoring of the system at any time.
Full input-to-output, input-to-case, output-to-case and output-to-
output isolation is provided. The converters are designed and
built according to the international safety standards IEC/EN
60950 and EN50155. They have been approved by the safety
agencies TÜV and UL (for USA and Canada).
The case design allows operation at nominal load up to 71 °C in a
free-air ambient temperature. If forced cooling is provided, the
ambient temperature may exceed 71 °C, but the case temperature
must remain below 95 °C under all conditions.
A temperature sensor generates an inhibit signal, which disables
the outputs if the case temperature
Tc
exceeds the limit. The
outputs are automatically re-enabled when the temperature drops
below the limit.
Various options are available to adapt the converters to individual
applications.
The converters may either be plugged into a 19" rack system
according to IEC 60297-3, or be chassis mounted. They are ideally
suited for Railway applications.
Important:
For applications requiring compliance with IEC/EN
61000-3-2 (harmonic distortion), please use our LS4000 and LS5000
Series with incorporated power factor correction (PFC).
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ....................................15
Immunity to Environmental Conditions ..................................17
Mechanical Data ....................................................................18
Safety and Installation Instructions ........................................19
Description of Options ............................................................23
Accessories ............................................................................32
EC-Declaration of Conformity ................................................33
Description ................................................................................1
Model Selection ........................................................................2
Part Number Description and Product Marking ........................3
Functional Description ..............................................................4
Electrical Input Data ..................................................................5
Electrical Output Data ..............................................................8
Auxiliary Functions ..................................................................12
APR 26, 2006 revised to SEP 25, 2006
Page 1 of 33
www.power-one.com
Dynamic duplication of variable definitions in structures
[i=s]This post was last edited by Qingchengshanxia on 2016-11-21 15:36[/i] I encountered a problem again in the past two days. Some variables in the structure are required to be dynamically defined se...
青城山下 Linux and Android
How to add components
Dear experts: Hello, I encountered a big problem during simulation. I needed a delay component RD5107, but there is no such component in the device library. What should I do? Is there an address to do...
Ivan49 Analog electronics
Use AT89C2051 countdown switch, please take a look
This is my graduation project. I was illiterate about single-chip microcomputers before, and I don't know how I was assigned to this topic. Please give me some advice. Requirements: "Be familiar with ...
zhousw08 Embedded System
[TI's first low power design competition] + low power test + 430BOOST-Nokia1202lcd + 0.1F supercapacitor low power test
[i=s] This post was last edited by IC Crawler on 2014-11-14 13:55 [/i] [size=3] [b] I have been in contact with 430 for a long time, but I have always had a clear understanding of the low power consum...
IC爬虫 Microcontroller MCU
Advantages of Inverted Buck for Low Power AC/DC Conversion
For offline power supplies, the flyback topology is a reasonable solution. However, if the end application of the design does not require isolation, the offline inverted buck topology has higher effic...
fish001 Energy Infrastructure?
Knowledge unit test of integrated operational amplifier circuits
The integrated operational amplifier circuit is mainly composed of four parts: , , , and . The bias circuit provides. The symbol of the integrated operational amplifier circuit is ------...
fighting Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 560  2630  1498  497  1115  12  53  31  10  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号