OM7646SM
SURFACE MOUNT POSITIVE ADJUSTABLE
1.5 AMP VOLTAGE REGULATOR
Isolated Hermetic Surface Mount Package
1.5 Amp, High Voltage, Positive Adjustable
Voltage Regulator
FEATURES
•
•
•
•
•
•
•
Hermetic Isolated Surface Mount Package
Adjustable Output Voltage
Eliminates Stocking Fixed Voltages
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Product Is Available Hi-Rel Screened
Electrically Similar To Industry Standard Type LM117HV
DESCRIPTION
This three terminal positive regulator is supplied in a hermetically sealed metal
surface mount package. All protective features are designed into the circuit, including
thermal shutdown, current limiting and safe-area control. With heat sinking, they can
deliver over 1.5 amp of output current. This unit features output voltages that can be
trimmed using external resistors, from 1.2 volts to 57 volts.
ABSOLUTE MAXIMUM RATINGS
@ 25°C
Input To Output Voltage Differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Typical Power/Thermal Characteristics:
Rated Power:
T
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.5W
T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W
Thermal Resistance:
θ
JC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2°C/W
θ
JA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42°C/W
Max. Lead Solder Temperature for 5 sec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225°C
MECHANICAL OUTLINE
.425
3.5
Pin Connections
Pin 1: V
OUT
Pin 2: Adjust
Pin 3: V
IN
Case: Isolated
2
.100
.200
.350 MIN.
± .020
.115
.160
1
3
.425
.035 WIDE
FLAT 3 PLCS.
.020
.080
4 11 R0
3.5 - 143
OM7646SM
ELECTRICAL CHARACTERISTICS
Parameter
Reference Voltage
Symbol
V
REF
-55°C ≤ T
A
≤ 125°C, I
L
= 8mA (unless otherwise specified)
Min.
1.20
•
•
•
1.20
1.20
1.20
-9
•
-23
-5
•
-10
-15
•
-15
-15
•
•
-15
-15
-16
Max.
1.30
1.30
1.30
1.30
9
23
5
10
15
15
15
15
15
16
Unit
Test Conditions
V
DIFF
= 3.0V, T
A
= 25°C
V
DIFF
= 3.3V
V
DIFF
= 40V
V
DIFF
= 60V
V
Line Regulation
(Note 1)
R
LINE
3.0V ≤ V
DIFF
≤ 40V, V
OUT
= V
ref
, T
A
= 25°C
3.3V ≤ V
DIFF
≤ 40V, V
OUT
= V
ref
40V ≤ V
DIFF
≤ 60V, V
OUT
= V
ref
, T
A
= 25°C
40V ≤ V
DIFF
≤ 60V, V
OUT
= V
ref
mV
Load Regulation
(Note 1)
R
LOAD
V
DIFF
= 3.0V, 10mA ≤ I
L
≤ 1.5A, T
A
= 25°C
V
DIFF
= 3.3V, 10mA ≤ I
L
≤ 1.5A
V
DIFF
= 40V, 10mA ≤ I
L
≤ 300mA, T
A
= 25°C
V
DIFF
= 40V, 10mA ≤ I
L
≤ 195mA
V
DIFF
= 60V, 10mA ≤ I
L
≤ 30mA
mV
Thermal Regulation
V
RTH
VIN = 14.6V, I
L
= 1.5A
P
d
= 20 Watts, t = 20 ms, T
A
= 25°C
f = 120 Hz, V
OUT
= V
ref
C
Adj
= 10 µF, I
OUT
= 100 mA
•
mV
dB
Ripple Rejection
(Note 2)
Adjustment Pin Current
R
N
66
I
Adj
V
DIFF
= 3.0V, T
A
= 25°C
V
DIFF
= 3.3V
V
DIFF
= 40V
V
DIFF
= 60V
•
•
•
-5
•
-5
-5
•
-5
-5
•
•
-5
-5
100
100
µA
100
100
5
5
5
5
5
5
5
5.0
•
•
•
0.3
0.05
5.0
5.0
7.0
1.5
A
0.50
µA
Adjustment Pin
Current Change
∆I
Adj
V
DIFF
= 3.0V, 10mA ≤ I
L
≤ 1.5A, T
A
= 25°C
V
DIFF
= 3.3V, 10mA ≤ I
L
≤ 1.5A
V
DIFF
= 40V, 10mA ≤ I
L
≤ 300mA, T
A
= 25°C
V
DIFF
= 40V, 10mA ≤ I
L
≤ 195mA
3.0V ≤ V
DIFF
≤ 40V, T
A
= 25°C
3.3V ≤ V
DIFF
≤ 40V
3.3V ≤ V
DIFF
≤ 60V
Miminum Load Current
I
Lmin
V
DIFF
= 3.0V, V
OUT
= 1.4V (forced)
V
DIFF
= 3.3V, V
OUT
= 1.4V (forced)
V
DIFF
= 40V, V
OUT
= 1.4V (forced)
V
DIFF
= 60V, V
OUT
= 1.4V (forced)
mA
Current Limit
(Note 2)
I
CL
V
DIFF
= 40V, T
A
= 25°C
V
DIFF
= 60V, T
A
= 25°C
3.5
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. If not tested, shall be guaranteed to the specified limits.
3. The • denotes the specifications which apply over the full operating temperature range.