POWER RELAY
1 POLE— 5 A
(MEDIUM LOAD CONTROL)
VE SERIES
n
FEATURES
l
RoHS compliant
UL, CSA, VDE, CQC recognized
l
1 form A (SPST-NO) or 1 form C (SPDT) contact
l
Low cost, miniature relay with big performance in small
package
—Higher surge voltage type is available (6,000 V)
—2,000 VAC between coil and contacts
l
Slim type—meets high density mounting requirement
l
Wide operating range
l
Easy circuit design with completely separated terminal
arrangement (coil and contact terminals)
l
Plastic sealed type
l
RoHS compliant since date code: 0434R
Please see page 8 for more information
l
Crepage min. 3.2 mm
n
ORDERING INFORMATION
[Example]
(a)
(b)
(c)
(d)
(e)
(f)
(g)
(h)
(i)
VE – 12 H M S E – K – HV – VD
(a) (*) (b) (c) (d) (e) (f ) (g) (h) (i)
VE : VE Series
Refer to the COIL DATA CHART
H : Heavy duty type
Nil : 1 form C (SPDT)
M : 1 form A (SPST-NO)
Nil : Standard type (360 mW)
S : High sensitivity type (250 mW)
Series Name
Nominal Voltage
Contact Rating
Contact Arrangement
Coil Type
Contact Material (Rating)
Enclosure
Surge Strength
Standard
Nil : Gold overlay silver-nickel (N.C.: 3 A, N.O.: 5 A)
E : Silver-nickel (N.C.: 3 A, N.O.: 5 A)
5 : Silver cadmium oxide (N.C.: 5 A, N.O.: 5 A)
K : Plastic sealed type
Nil : Standard type (4,000 V)
HV High dielectric strength type (6,000 V)
:
VD: UL, CSA, VDE approved type
Note: ctual marking omits the hyphen (-) of (*)
A
1
VE SERIES
n
COIL DATA CHART
MODEL
VE-( ) HM VE-( ) HME
VE-( ) H VE-( ) HE
High Sensitive Type
Standard Type
VE- 5H (M) (E)-K
VE- 6H (M) (E)-K
VE- 9H (M) (E)-K
VE 12H (M) (E)-K
VE-18H (M) (E)-K
VE-24H (M) (E)-K
VE-48H (M) (E)-K
VE- 5H (M) S (E)-K
VE- 6H (M) S (E)-K
VE- 9H (M) S (E)-K
VE 12H (M) S (E)-K
VE-18H (M) S (E)-K
VE-24H (M) S (E)-K
VE-48H (M) S (E)-K
VE-( ) HM5
VE-( ) H5
VE- 5H (M) 5-K
VE- 6H (M) 5-K
VE- 9H (M) 5-K
VE-12H (M) 5-K
VE-18H (M) 5-K
VE-24H (M) 5-K
VE-48H (M) 5-K
VE- 5H (M) S5-K
VE- 6H (M) S5-K
VE- 9H (M) S5-K
VE-12H (M) S5-K
VE-18H (M) S5-K
VE-24H (M) S5-K
VE-48H (M) S5-K
Nominal
voltage
5 VDC
6 VDC
9 VDC
12 VDC
18 VDC
24 VDC
48 VDC
5 VDC
6 VDC
9 VDC
12 VDC
18 VDC
24 VDC
48 VDC
Coil
resistance
(±10%)
69 Ω
100 Ω
225 Ω
400 Ω
900 Ω
1,600 Ω
6,400 Ω
100 Ω
145 Ω
325 Ω
575 Ω
1,300 Ω
2,310 Ω
9,220 Ω
Must
operate
voltage*
3.5 VDC
4.2 VDC
6.3 VDC
8.4 VDC
12.6 VDC
16.8 VDC
33.6 VDC
3.6 VDC
4.3 VDC
6.5 VDC
8.6 VDC
13.0 VDC
17.3 VDC
34.7 VDC
Must
release
voltage*
0.25 VDC
0.3 VDC
0.45 VDC
0.6 VDC
0.9 VDC
1.2 VDC
2.4 VDC
0.25 VDC
0.3 VDC
0.45 VDC
0.6 VDC
0.9 VDC
1.2 VDC
2.4 VDC
Nominal
power
360 mW
360 mW
360 mW
360 mW
360 mW
360 mW
360 mW
250 mW
250 mW
250 mW
250 mW
250 mW
250 mW
250 mW
Note: All values in the table are measured at 20 °C.
*: Specified values are subject to pulse voltage.
2
VE SERIES
n
SPECIFICATIONS
Item
Contact
Coil
Time Value
Life
Other
Arrangement
Material
Style
Resistance (initial) (at 1 A 6 VDC)
Rating (resistive)
Maximum Carrying Current
Maximum Switching Power
Maximum Switching Voltage
Maximum Switching Current
Minimum Switching Load*
1
Nominal Power (at 20°C)
Operate Power (at 20°C)
Operating Temperature
Operate (at nominal voltage)
Release (at nominal voltage)
Mechanical
Electrical (at Rating)
Vibration Misoperation
Resistance
Endurance
Shock Misoperation
Resistance
Endurance
Weight
VE-( ) HM(S)E-K
VE-( ) HM(S)-K
VE-( ) H(S)E-K
VE-( ) H(S)-K
VE-( ) HM(S)5-K
VE-( ) H(S)5-K
1 form A (SPST-NO) 1 form C (SPDT) 1 form A (SPST-NO) 1 form C (SPDT)
Gold overlay silver nickel, silver nickel Silver-cadmium oxide alloy
Single
Maximum 70 mΩ (VE-HM, H)
Maximum 100 mΩ (VE-HME, HE)
Maximum 200 mΩ
5 A 250 VAC 5 A 250 VAC (N.O.) 5 A 250 VAC
3 A 250 VAC (N.C.)
7 A
1,250 VA (N.O.)
1,250 VA
750 VA (N.C.)
250 VAC, 150 VDC
5 A 5 A (N.O.) 5 A
3 A (N.C.)
10 mA, 5 VDC (VE-HM, H), 100 mA 5 VDC (VE-HME, HE, HM5, H5)
Standard type: 360 mW. High sensitivity type: 250 mW
Standard type: 177 mW. High sensitivity type: 130 mW
Standard: –40°C to +85°C. High sensitivity: –40°C to +90°C (no frost)
Maximum 10 ms
Maximum 5 ms
1 × 10
7
operations minimum
Standard Type: 1 × 10
5
ops. min. High sensitivity type: 5 x 10
4
ops. min.
10 to 55 Hz (double amplitude of 3.3 mm)
10 to 55 Hz (double amplitude of 3.3 mm)
100 m/s
2
(11 ±1 ms)
500 m/s
2
(6 ±1 ms)
Approximately 8 g
1,250 VA
*
1
Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load
before production since reference values may vary according to switching frequencies, environmental conditions and
expected reliability levels.
3
VE SERIES
n
INSULATION
Item
Resistance (initial)
Dielectric
Strength
open contacts
VE - ( ) HME
VE - ( ) HM
1,000 VAC
1 min.
VE - ( ) HE
VE - ( ) H
750 VAC
1 min.
VE - ( ) HM5 VE - ( ) H5
Note
at 500 VDC
1,000 VAC
1 min.
750 VAC
1 min.
1.2 x 50µs
standard wave
Minimum 1,000 MΩ 1 min.
coil and contacts 2,000 VAC 1 min.
Surge Voltage
(coil and contact)
Standard: 4,000 V, High Sensitive: 6,000V
n
SAFETY STANDARDS
Type
UL
CSA
Compliance
UL 508
E56140
C22.2 No. 14
LR 35579
Contact rating
Flammability: UL 94-V0 (plastics)
VE-( )-H:
5A, 250VA/30VDC (N.O. resistive)
3A, 250VAC (N.C. resistive)
5A, 30VDC (N.C. resistive)
1/14 HP, 250VAC /125VAC
VE-( )-HM
5A, 250VAC/30VDC (resistive)
1/12 HP, 250VAC /125VAC
VE-( )-H5
5A, 250VAC/30VDC (N.O. resistive)
1/10 HP, 250VAC /125VAC (N.O. resistive)
5A, 250VAC/30VDC (N.C. resistive)
1/14 HP, 250VAC /125VAC (N.C. resistive)
VE-( )-HM5
5A, 250VAC/30VDC (resistive)
1/10 HP, 250VAC /125VAC
VDE
Complies with CQC
4
VE SERIES
n
REFERENCE DATA
5