EEWORLDEEWORLDEEWORLD

Part Number

Search

PT00P-20-39SY(005)

Description
MIL Series Connector
CategoryThe connector    The connector   
File Size225KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Download Datasheet Parametric View All

PT00P-20-39SY(005) Overview

MIL Series Connector

PT00P-20-39SY(005) Parametric

Parameter NameAttribute value
MakerAmphenol
Reach Compliance Codeunknown
Connector typeMIL SERIES CONNECTOR
Manufacturer's serial numberPT00P
PT00 (MS3110)
SP00
wall mounting receptacle
(TP)
S
R
PT
.120 ± .005 Dia.
(.147 ± .005 Dia., size 24)
SP
.150 ± .005 Dia.
(TP)
M
L
Q
R S
4 Holes
A
“PG” Cable Gland Seal
K
“A” General Duty/
“C” Pressurized“
“A” (SR), “E” (SR), “P” (SR),
MS / “F” Strain Relief
Z
“P” Potting Boot
L
TERMINATION ASSEMBLIES
“E” Open Wire Seal
L
V
L
L
L
N
D
PT00PG-XX-XXX
N
D
N
GDH
N
N
D
“J” Cable Seal
.375 MIN
PT00A-XX-XXX
SP00A-XX-XXX
PT00C-XX-XXX
C
PT00E-XX-XXX
SP00E-XX-XXX
MS3110E-XX-XXX
PT00P-XX-XXX
SP00P-XX-XXX
MS3110P-XX-XXX
RELEASED / Dec . 21 2015, 2:09:12 PM
XL
PT00A-XX-XXX (SR)
SP00A-XX-XXX (SR)
PT00E-XX-XXX (SR)
SP00E-XX-XXX (SR)
PT00P-XX-XXX (SR)
SP00P-XX-XXX (SR)
MS3110F-XX-XXX
To complete part number see how to order on page 25.
n
(MMC) located within .0025 of (TP)
Receptacle Front View
R
S
(TP)
Max.
PT
SP
PT
SP
A
+.001
–.005
K +.020
–.010
PT
SP
P
N
D
MS3110J-XX-XXX
Receptacle Side View
M +.010
Q
–.000
L
Thread
Max.
PT
SP
Class 2A
Class “A”, “C”
D
Min.
L
Max.
N
Max.
V
Thread
Class A
Shell
Size
6
8
10
12
14
16
18
20
22
24
.469
.594
.719
.812
.906
.969
1.062
1.156
1.250
1.375
.641
.734
.812
.938
1.031
1.125
1.203
1.297
1.375
1.500
.688
.812
.938
1.031
1.125
1.219
1.312
1.438
1.562
1.688
.953
1.047
1.125
1.250
1.344
1.438
1.516
1.672
1.750
1.875
H
Max.
.348
.473
.590
.750
.875
1.000
1.125
1.250
1.375
1.500
L
Max.
.493
.493
.493
.493
.493
.493
.493
.650
.650
.683
.524 .906
.524 .906
.524 .906
.524 .906
.524 .906
.524 .906
.524 .906
.650 1.125
.650 1.125
.683 1.188
L
Max.
.431
.431
.431
.431
.431
.431
.431
.556
.556
.589
.462
.462
.462
.462
.462
.462
.462
.556
.556
.589
.3125-32 NEF
.4375-28 UNEF
.5625-24 NEF
.6875-24 NEF
.8125-20 UNEF
.9375-20 UNEF
1.0625-18 NEF
1.1875-18 NEF
1.3125-18 NEF
1.4375-18 NEF
L
Max.
N
Max.
.468
.468
.468
.468
.468
.468
.531
.531
.531
.498
Z
Max.
PT
SP
.438 .175 1.553 .462
.438 .297 1.553 .590
.438 .421 1.553 .717
.438 .546 1.553 .834
.438 .663 1.553 .970
.438 .787 1.553 1.088
.438 .879 1.553 1.216
.531 1.014 1.703 1.332
.531 1.134 1.703 1.460
.498 1.259 1.765 1.585
XL
Max.
.3750-32 NEF
.5000-28 UNEF
.6250-24 NEF
.7500-20 UNEF
.8750-20 UNEF
1.0000-20 UNEF
1.1875-18 NEF
1.1875-18 NEF
1.4375-18 NEF
1.4375-18 NEF
Class “PG”
L
Max.
Class “A” (SR), “E” (SR), “P” (SR), MS / “F”
Shell
C
Size Thread
Class “E”, MS / “E”
Class “P”, MS / “P”
6
8
10
12
14
16
18
20
22
24
6-32
6-32
6-32
6-32
6-32
8-32
8-32
8-32
8-32
.240
.302
.428
.552
.615
.740
.740
.928
.990
D
Min.
.125
.188
.312
.375
.500
.625
.625
.750
.800
G
Max.
.812
.875
1.000
1.125
1.188
1.438
1.438
1.625
1.719
1.922
1.922
1.922
1.922
2.047
2.078
2.344
2.344
2.406
.550
.675
.803
.920
1.047
1.165
1.290
1.418
1.543
N
Max.
1.266
1.266
1.266
1.266
1.266
1.266
1.266
1.516
1.516
1.578
.440
.560
.685
.813
.930
1.057
1.175
1.301
1.430
1.555
N
Max.
.192
.317
.434
.548
.673
.798
.899
1.024
1.149
1.274
D
Min.
1.438
1.438
1.438
1.438
1.438
1.438
1.438
1.656
1.656
1.717
.484
.608
.734
.858
.984
1.110
1.234
1.360
1.484
1.610
Class “J”
D
N
Closed Free Max.
.168
.205
.338
.416
.550
.600
.635
.670
.740
.230
.312
.442
.539
.616
.672
.747
.846
.894
.547
.675
.812
.940
1.067
1.194
1.322
1.449
1.576
2.271
2.271
2.411
2.599
2.943
3.172
3.610
3.766
3.985
M12x1.5-6H
M16x1.5-6H
M16x1.5-6H
M18x1.5-6H
M22x1.5-6H
M25x1.5-6H
M25x1.5-6H
M32x1.5-6H
M32x1.5-6H
B
Thread
.936
.936
.936
.936
.936
.936
1.180
1.180
1.180
All dimensions for reference only.
13
Active low-pass filter -3-dB frequency at 1 Hz, what does it mean?
I read a foreign paper about active filters. What does 3-dB frequency at 1 Hz mean? Here is a whole paragraph: All the analogue signal conditioning paths concluded with a corresponding unity gain four...
SEVEN917 Analog electronics
Ask about the parameters of DA
Does anyone know what the setting up time and sample/update rate MSPS often mentioned in DA chip datasheets mean? Also, what is the fclk (which seems to be the parameter given by Maxim)? Do Maxim's fc...
scx0704 Embedded System
AD7953 Sampling Speed Issue
This chip. Is it a fixed sampling frequency of 1MHz, and the SPI transmission speed can reach up to 20MHz? Is this the correct understanding? eeworldpostqq...
jishizhong Analogue and Mixed Signal
Interrupt-Based Ambient Light and Environment Sensor Node Reference Design for Sub-1 GHz Networks
The TI Design demonstrates a low-power approach to wireless environmental sensing that ensures up to 10 years of battery life.This design uses the Texas Instruments (TI) SimpleLink ultra-low-power Sub...
Jacktang RF/Wirelessly
How to dynamically load local drivers in WinCE
[HKEY_LOCAL_MACHINE\Drivers\BuiltIn\SNMP] "Dll"="snmp.dll" "Order"=dword:3 "Keep"=dword:1 "Entry"="SnmpInitialize" For example, how to dynamically load this driver?...
zhaolequan Embedded System
A brief talk about state machine
Many times, I feel that state machines are incomprehensible. I have written a lot, but when others ask me about them, I still feel that I have never come into contact with this thing. Just like last t...
changhcl FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 940  2107  1438  832  794  19  43  29  17  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号