Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
-
Load
Ag (Au-Alloy)
Resistive load
Bifurcated crossbar
0.3 A at 125 VAC,
1 A at 30 VDC
1A
125 VAC, 110 VDC
1A
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
■Characteristics
Classification
Item
Contact resistance *1
Operating (set) time
Release (reset) time
Minimum set/reset pulse width
Insulation resistance *2
Between coil and contacts
Dielectric strength
Between contacts of different polarity
Between coil and contacts
Impulse withstand
voltage
Between contacts of different polarity
Between contacts of the same polarity
Vibration resistance
Shock resistance
Durability
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
Model
100 mΩ max.
3 ms max.
3 ms max.
−
1,000 MΩ min. (at 500 VDC)
1,500 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
2,500 VAC, 2
×
10
μs
1,500 VAC, 10
×
160
μs
10 to 55 to 10 Hz 2.5 mm single amplitude (5 mm double amplitude)
10 to 55 to 10 Hz 1.65 mm single amplitude (3.3 mm double amplitude)
1,000 m/s
2
750 m/s
2
50,000,000 operations min. (at 36,000 operations/hour)
100,000 operations min. (with a rated load at 1,800 operations/hour)
10
μA
at 10 mVDC
-40 to 85°C (with no icing or condensation)
5% to 85%
Approx. 1.0 g
10 ms
Single-side stable
G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y
Single-winding latching
G6JU-2P-Y, G6JU-2FS-Y, G6JU-2FL-Y
Between contacts of the same polarity 750 VAC, 50/60 Hz for 1 min
Failure rate (P level) (reference value) *3
Ambient operating temperature
Ambient operating humidity
Weight
Note: The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
*2. The insulation resistance was measured with a 500 VDC Megger Tester applied to the same parts as those for checking the dielectric strength.
*3. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50
Ω.
This value may vary depending on the
operating frequency, operating conditions, expected reliability level of the relay, etc. Always double-check relay suitability under actual load conditions.
2
G6J-Y
■Engineering
Data
●Maximum
Switching Capacity
Switching current (A)
10
7
5
3
Surface-mounting Relay
●Durability
Durability (x10
4
operations)
●Ambient
Temperature vs.
Maximum Voltage
Maximum voltage (%)
1,000
500
300
250
200
100
50
30
AC resistive load
1
0.7
0.5
0.3
DC resistive load
30 VDC resistive load
Ambient temperature:
23°C
Switching
frequency:
1,800 operations/hour
150
100
10
5
3
125 VAC resistive load
Ambient temperature:
23°C
Switching
frequency:
1,800 operations/hour
50
0.1
1
3
5
10
30 50
100
300 500 1,000
1
0
0.2
0.4
0.6
0.8
1
1.2
0
−40
−20
0
20
40
60
80
100
Switching voltage (V)
Switching current (A)
Ambient temperature (°C)
●Ambient
Temperature vs.
Switching Current
Switching current (A)
1.2
●Ambient
Temperature vs. Must
Operate or Must Release Voltage
Change rate on the
basis
of rated voltage (%)
100
90
80
70
60
50
Maximum estimated value
max.
avg.
min.
●Shock
Malfunction
Y
1,000
800
X
1,000
Note: “Maximum voltage” is the maximum voltage
that can be applied to the Relay coil.
Energized
1
0.8
600
De-
energized
400
200
Z
1,000
0.6
200
40
30
20
10
Operating voltage
Release voltage
−40
−20
0
20
40
60
80
100
max.
avg.
min.
G
6
J
Y
-
0.4
1,000
Z'
Shock directions
X
X'
Y
Z
Z'
Y'
400
600
800
1,000
1,000
X'
0.2
0
−40
Y'
−20
0
20
40
60
80
100
0
−60
Unit: m/s
2
Sample:
G6J-2P-Y
Number
of Relays: 10
pcs
Ambient temperature (°C)
Ambient temperature (°C)
●Electrical
Durability (with Operate
and Release Voltage)
*1
On the basis of rated voltage (%)
100 Sample: G6J-2P-Y
Number of Relays: 10 pcs
Test conditions: 1A resistive load at
30 VDC with an operation rate of 50%
80 Switching frequency: 1,800 operations/hour
●Electrical
Durability
(Contact resistance)
*1
Contact resistance (m
Ω
)
1,000
Sample: G6J-2P-Y
Number of Relays: 10 pcs
500 Test conditions: 1A resistive load
at 30 VDC with an operation rate
of 50% Switching frequency:
300 1,800 operations/hour
NO contact
NC contact
Test Conditions: Shock is applied in ±X, ±Y, and ±Z
directions three times each with and
without energizing the Relays to check
the number of contact malfunctions.
●Contact
Reliability Test
(Contact resistance)
*1, *2
Contact resistance (m
Ω
)
1,000
Sample: G6J-2P-Y
Number of Relays: 10 pcs
500 Test conditions: 10
μA
resistive
load at 10 m VDC with an
operation rate of 50%
300 Switching frequency: 7,200
operations/hour
NO contact
NC contact
max.
min.
60
Operate voltage
100
max.
40
100
50
min.
Release voltage
20
30
Contact resistance
max.
max.
min.
min.
max.
max.
50
30
Contact resistance
min.
min.
0
0.001 0.01
0.1
1
10
100
1,000
10
0.001 0.01
0.1
1
10
100
1,000
10
0.001 0.01
0.1
1
10
100
1,000
Operating frequency (x10
3
operations)
Operating frequency (x10
3
operations)
Operating frequency (x10
5
operations)
●Mutual
Magnetic Interference
Change rate on the
basis of initial value (%)
+30
+20
+10
0
−10
−20
−30
+30
+20
+10
0
−10
−20
−30
Average value
Must operate voltage
Must release voltage
Average value
Initial Installed in flush
stage
configuration
Initial Installed in flush
stage
configuration
●Mutual
Magnetic Interference
Change rate on the
basis of initial value (%)
+30
+20
+10
0
−10
−20
−30
+30
+20
+10
0
−10
−20
−30
Average value
Must operate voltage
Must release voltage
Average value
Initial Installed in flush
stage
configuration
Initial Installed in flush
stage
configuration
*1.
*2.
Sample
Not
energized
Sample
Not energized
The tests were conducted at an ambient
temperature of 23°C.
The contact resistance data are periodically
measured reference values and are not
values from each monitoring operation.
Contact resistance values will vary
according to the switching frequency and
operating environment, so be sure to check
operation under the actual operating
conditions before use.
Change rate on the
basis of initial value (%)
Sample
Energized
Sample
Energized
Change rate on the
basis of initial value (%)
3
G6J-Y
●External
Magnetic Interference
(Average value)
Change rate on the basis of initial value (%)
Change rate on the basis of initial value (%)
+30
S
+20
N
+30
S
+20
N
Surface-mounting Relay
(Average value)
Change rate on the basis of initial value (%)
+30
S
+20
N
(Average value)
+10
+10
+10
0
0
0
−10
−10
−10
−20
−30
−1,200
Sample: G6J-2P-Y
Number of Relays: 5 pcs
−800
−400
0
Operate voltage
Release voltage
400
800 1,200
−20
−30
−1,200
Sample: G6J-2P-Y
Number of Relays: 5 pcs
−800
−400
0
Operate voltage
Release voltage
400
800 1,200
−20
−30
−1,200
Sample: G6J-2P-Y
Number of Relays: 5 pcs
−800
−400
0
Operate voltage
Release voltage
400
800 1,200
External magnetic field (A/m)
External magnetic field (A/m)
External magnetic field (A/m)
●High-frequency
Characteristics
(Isolation)
*1, *2
(Average value (initial))
Isolation (dB)
●High-frequency
Characteristics
(Insertion Loss)
*1, *2
(Average value (initial))
Insertion Loss (dB)
●High-frequency
Characteristics
(Return Loss, V.SWR)
*1, *2
(Average value (initial))
Return loss (dB)
0
10
20
2-pole return loss
30
3.5
3
2.5
V.SWR
0
10
20
30
2-poles
40
50
60
70
80
90
100
1
1-pole
0
G
6
J
Y
0.5
1-pole
1
Number of contacts
Number of contacts
35
30
25
20
15
10
5
Sample: G6J-2P-Y
Number of Relays: 30 pcs
Operate time
Release time
Operate bounce time
35
30
25
20
15
10
5
Sample: G6J-2P-Y
Number of Relays: 30 pcs
1.5
2
2.5
3
Time (ms)
Release bounce time
Change rate on the basis of rated value (%)
-
2-poles
1-pole return loss
2
1.5
1.5
40
50
1
2-pole V.SWR
1-pole V.SWR
2
60
0.5
0
2.5
10
100
1,000
1
10
100
1,000
Frequency (MHz)
Frequency (MHz)
70
1
10
100
1,000
Frequency (MHz)
●Must
Operate and Must Release
Time Distribution
*1
40
●Distribution
of Bounce Time *
1
40
●Vibration
Resistance
5.0
4.0
3.0
2.0
1.0
Operate voltage
0.0
−1.0
−2.0
−3.0
−4.0
−5.0
Initial
After
Release voltage
0
0.5
1
1.5
2
2.5
3
0
0.5
1
Time (ms)
*1.
*2.
The tests were conducted at an ambient temperature of 23°C.
High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics, including endurance, in the actual machine
before use.
4
G6J-Y
■Dimensions
PCB Terminals
G6J-2P-Y
G6JU-2P-Y
10.6
5.7
7.6
5.4
3.2
Surface-mounting Relay
(Unit: mm)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
G6J-2P-Y
Orientation mark
9
Eight, 0.85-dia.
holes
1
2
3
4
3.5
0.3
1.5
3.2
5.4
7.6
0.4
3.2
0.15
(1.5)
(1.25)
3.2
8
7
6
5
G6JU-2P-Y
Orientation mark
1
2
3
4
Note: Each value has a tolerance of ±0.3 mm.
S R
8
7
6
5
Note:Check carefully the coil polarity of the Relay.
Surface-mounting Terminals (Short)
G6J-2FS-Y
G6JU-2FS-Y
10.6
5.7
Mounting Dimensions
(TOP VIEW)
Tolerance ±0.1 mm
7.6
5.4
3.2
Terminal Arrangement/
Internal Connections
(TOP VIEW)
G6J-2FS-Y
Orientation mark
2.35
8
7
6
5
G
6
J
Y
-
10.0 max.
4.35
1
2
3
4
1.5
3.2
5.4
7.6
0.4
3.2
5.7
0.8
(1.5)
G6JU-2FS-Y
Orientation mark
Note 1. Each value has a tolerance of ±0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
8
7
6
5
S R
1
2
3
4
Note:Check carefully the coil polarity of the Relay.
Surface-mounting Terminals (Long)
G6J-2FL-Y
G6JU-2FL-Y
10.6
5.7
Mounting Dimensions
(TOP VIEW)
Tolerance ±0.1 mm
7.6
5.4
3.2
Terminal Arrangement/
Internal Connections
(TOP VIEW)
G6J-2FL-Y
Orientation mark
3.2
8
7
6
5
10.0 max.
5.2
1
1.5
3.2
5.4
7.6
0.4
3.2
7.4
0.8
(1.5)
2
3
4
G6JU-2FL-Y
Orientation mark
Note 1. Each value has a tolerance of ±0.3 mm.
Note 2. The coplanarity of the terminals is 0.1 mm max.
8
7
6
5
S R
1
2
3
4
Note:Check carefully the coil polarity of the Relay.