5962R0720201KXC

Description
DC-DC Regulated Power Supply Module, 2 Output, 35W, Hybrid, FM-12
CategoryPower/power management    The power supply circuit   
File Size1MB,44 Pages
ManufacturerCrane Co.
Download Datasheet Parametric View All

5962R0720201KXC Overview

DC-DC Regulated Power Supply Module, 2 Output, 35W, Hybrid, FM-12

5962R0720201KXC Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerCrane Co.
package instruction, MODULE,14LEAD,3.0
Reach Compliance Codecompliant
Other features-12V ADDITIONAL OUTPUT AVAILABLE
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage56 V
Minimum input voltage19 V
Nominal input voltage28 V
JESD-30 codeR-XDFM-P12
Number of functions1
Output times2
Number of terminals12
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Maximum output current1.46 A
Maximum output voltage12.42 V
Minimum output voltage11.58 V
Nominal output voltage12 V
Package body materialUNSPECIFIED
Encapsulate equivalent codeMODULE,14LEAD,3.0
Package shapeRECTANGULAR
Package formFLANGE MOUNT
Certification statusQualified
Filter levelMIL-PRF-38534 Class K
surface mountNO
technologyHYBRID
Temperature levelMILITARY
Terminal formPIN/PEG
Terminal locationDUAL
total dose100k Rad(Si) V
Maximum total power output35 W
Fine-tuning/adjustable outputNO
Crane Aerospace & Electronics Power Solutions
sMrt single, dual and triple space dc-dc converters
Features
19-56 Volt input – 35 Watt – space qualiFied
• Radiation tolerant space DC-DC converter
- Total ionizing dose (TID) guaranteed per MIL-STD-883
method 1019, radiation hardness assurance (RHA)
P = 30 krad(Si), L = 50 krad(Si), R = 100 krad(Si)
- 50 - 300 rad(Si)/sec dose rate (Condition A)
- 10 mrad(Si)/sec dose rate (Condition D)
- Single event effects (SEE) LET performance to
86 MeV cm
2
/mg
• Built in MIL-STD-461 EMI filter
• Output trim from 51% to 125% of nominal
• Operating temperature -55° to +125°C
• Input voltage range 19 to 56 volts
• Fully isolated, 5 port isolation
• Magnetic feedback
• Qualified to MIL-PRF-38534 Class H and K
• Transient protection 80 volts for 120 ms
• Remote sense
• Fixed high frequency switching
• Inhibit function
• Synchronization input
• Meets MIL-STD-704A transient standards
• Indefinite short circuit protection
MODELS
O
utput
V
Oltage
(V)
SINGLE
3.3
5
8.7
12
15
DUAL
Vout A 5 V, Vout B 5 V
Vout A 12 V, Vout B 12 V
Vout A 15 V, Vout B 15 V
TRIPLE
+3.3 & ±12
+3.3 & ±15
+5 & ±7
+5 & ±12
+5 & ±15
description
The Interpoint
®
SMRT Series™ of DC-DC converters offers
up to 35 watts of power in a radiation tolerant design. The low
profile SMRT converters are manufactured in our fully certified
and qualified MIL-PRF-38534 Class K production facility and
packaged in hermetically sealed steel cases. They are ideal for
use in programs requiring high reliability, small size, and high
levels of radiation hardness assurance.
The SMRT converters are switching regulators which use
a two-phase, phase shifted flyback design with a nominal
switching frequency of 300 kHz. Tight regulation is maintained
with advanced constant frequency pulse width modulation
design techniques. The SMRT’s feed-forward compensation and
discontinuous topologies provide high levels of input-to-output
ripple rejection. See Figure 10 on page 29, Figure 29 and
Figure 30 on page 33 and Figure 45 and Figure 46 on page
36.
Crane Aerospace & Electronics
Power Solutions – Interpoint Products
10301 Willows Rd. NE, Redmond, WA 98052
+1 425.882.3100 • power@crane-eg.com
www.craneae.com/interpoint
Two independent feedback loops are used to regulate the dual
and triple outputs, one feedback loop regulates the two-phased
single output. Each set of outputs is electrically isolated from the
other and from the input. This product configuration eliminates
cross regulation effects between output sets.
Configurations:
• Single Output: One dual-phase output
• Dual Output: Two isolated single-phase outputs
• Triple Output: One single-phased output (Main) isolated
from one single-phase dual output (± Auxiliary)
SMRT28 Rev AK - 2017.11.20
Page 1 of 44
MicroPython can start without SD card
In the STM32 branch, when booting, if there is no SD card, it will boot from the internal Flash (read boot.py and main.py from the PYBFlash generated by the internal Flash), otherwise it will boot fro...
dcexpert MicroPython Open Source section
Help
What is the function of Figure 1D1 and how does it work? Please explain...
wensir Analog electronics
Six tips for PCB layout design to make drawing easier!
Six things to consider when transferring PCB schematics to layout design.All examples mentioned were developed using the Multisim design environment, but the same concepts apply when using different E...
btty038 PCB Design
[Sipeed LicheeRV 86 Panel Review] 9- Flashing LED
This article will introduce the LED control of the LicheeRV 86 Panel. The Linux system in SD already has a driver for LED. This article controls the LED by operating files at the application layer (ev...
DDZZ669 Domestic Chip Exchange
Watch the video to win a JD card | Highlights of Micron's keynote at Computex Taipei 2022
Recently, this year's Taipei International Computer Show (hereinafter referred to as COMPUTEX 2022) has come to a successful conclusion. COMPUTEX 2022 focuses on six major themes: "Innovative Computin...
EEWORLD社区 Integrated technical exchanges
Help: How to assign values to the EM78P153 code option registers word0, word1, and word2
[table=98%,rgb(238, 238, 238)] [tr][td]As the title says, EM78P153 provides three code option registers, but the datasheet says that they cannot be accessed during program execution. How can I assign ...
华叶春秋 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2517  2224  1391  2886  1611  51  45  28  59  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号