EEWORLDEEWORLDEEWORLD

Part Number

Search

851-07H8-3APW5144

Description
MIL Series Connector, 3 Contact(s), Steel, Nickel Plated, Male, Receptacle,
CategoryThe connector    The connector   
File Size1MB,26 Pages
ManufacturerSOURIAU
Download Datasheet Parametric View All

851-07H8-3APW5144 Overview

MIL Series Connector, 3 Contact(s), Steel, Nickel Plated, Male, Receptacle,

851-07H8-3APW5144 Parametric

Parameter NameAttribute value
MakerSOURIAU
Reach Compliance Codeunknown
Other featuresPOLARIZATION AVAILABLE, SHIELDED, CONTACT MATERIAL:COPPER, 1500VAC, 1BAR
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact completed and terminatedTIN LEAD
Contact point genderMALE
Coupling typeBAYONET
DIN complianceNO
IEC complianceNO
JESD-609 codee0
MIL complianceNO
Installation typePANEL
OptionsHERMETIC
Shell materialSTEEL, NICKEL PLATED
Total number of contacts3
souriau
851 Series
Applications
Former connector for military applications.
Now used in the fields of professional and
general electronics.
Description
• bayonet coupling
• environmental and hermetic versions
• solder, crimp, straight spills and wire wrap versions
• thermocouple contacts available
• cadmium free plating (Zinc Cobalt) version
Standards
Mil-C 26482 G series 1
NFC 93422-He 301 B
VG 95328
BS 9522 F 0017
GAM T1 list
QPL approved (solder version)
Characteristics
Mechanical
• Shell :
environmental version : aluminium alloy plating :
- olive green cadmium
- black anodised
- white cadmium
- satin finish bright nickel
- zinc cobalt (olive green)
hermetic version : steel
plating : - iridescent yellow cadmium
- nickel
• Insulator :
front section : neoprene elastomer (85 shore)
rear section : neoprone elastomer (40 shore)
• Contact :
crimp : inserted and removed from rear of insulator
retained by metallic clip ; solder and straight spills :
non removable ; wire wrap : removable or not remo-
vable
- material : copper alloy
- plating : gold overall or gold plated active zone
and tin/lead plated termination
- min retention force of contacts in insulator
contact size
20 (Ø 1 mm)
16 (Ø 1,6 mm)
crimp
68 N
113 N
solder straight spill ww
68 N
113 N
- hermetic version :
size 20 : 30 mΩ
• Shielding : 70 db to 5 MHz
size 16 : 14 mΩ
40 db to 100 MHz
• Mechanical endurance : 500 cycles (full mating-unmating)
Electrical
• Dielectric withstanding voltage :
• at standard pressure :
mated and unmated connectors
- 1 500 Vrms between size 20 contacts (service 1)
- 2 300 Vrms between size 16 contacts (service 2)
- 1 500 Vrms between mixed size 20
and 16 contacts (service 1)
• at reduced pressure (10 mbar) :
connectors mated and unmated
- 200 Vrms between size 20 contacts (service 1)
- 300 Vrms between size 16 contacts (service 2)
• Insulation resistance :
5 000 MΩ under 500 Vdc
• Current rating per contact :
size 20 : 7,5 A
size 16 : 13 A
• Contact resistance :
- environmental version :
size 20 : 4 mΩ
size 16 : 3 mΩ
Climatic
• Working temperature :
-55°C to +125°C
• Sealing :
crimp contact version, 1 bar differential
pressure, leakage
8 cm3/hr
- solder contact version, 2 bar differential pressure,
leakage
16 cm3/hr
• Hermiticity :
1 bar differential pressure leakage
2,8 mm3/hr
• Chemical resistance :
to MIL-C 26482 G series 1 and
NFC 93422-HE 301 B code A
• Resistance to salt spray :
48 hours at environmental temperature
- damp heat : 21 days
• Vibration :
to NFC 20-616
Ordering information
- Environmental connectors
basic series
shell type :
solder
00
01
02E
07
07A
06
08
36
76
crimp
00
-
01
-
02R
-
07
-
-
06
-
08
-
36
-
76
-
square flange receptacle accepting backshells
cable connecting receptacle
square flange receptacle not accepting backshells
jam nut receptacle accepting backshells
jam nut receptacle not accepting backshells
plug for use with straight backshells
plug for use with 90° backshells
screened plug for use with straight backshells
screened plug with lock finger
solder version
crimp version
851 - 00 E
851 - 00 R
8 - 3A
8 - 3A
P
P
50 •••
50 •••
backshell type :
shell size :
contact layout :
contact type :
orientation :
obligatory suffix :
see table
8 - 10 - 12 - 14 - 16 - 18 - 20 - 22 - 24
see table p 18
P
= male -
S
= female
normal (not included in part number)
W, X, Y, Z,
see table p 19
50
51
52
gold plated crimp contacts - solder contacts size 20 - contacts with a gold plated active zone
and tin plated terminations - other gold plated terminations
solder contacts gold plated size 20
zinc cobalt olive green plated (contacts : idem specif. 50)
olive green cadmium plate (without specification)
white cadmium plate
black anodised (solder contacts)
black anodised (crimp contacts)
nickel plate
nickel plate
backshell type T* and RT*
olive green cadmium plate
specification :
-
02
29
031
44
38
42
}
14
A new button to eliminate zero replies has been added. Come and try it when you have time!
[size=3][font=微软雅黑]When people post questions on forums, they may not get a reply in time due to unpopular, niche, unclear description and other reasons. When they look back after a while, they find t...
eric_wang Suggestions & Announcements
My C Exercise (6) - This is a relatively complex string processing function
Actually, I started to modify it last night. I found many bugs that I didn't notice at the beginning. I also modified some sub-functions. But so far, I still don't fully understand the last code block...
辛昕 Programming Basics
I think the more useful single chip books
If you think it's good, please give it a thumbs up. Thank you....
door5719 MCU
Design and implementation of PIII computer system based on embedded PC
At present, the application of embedded computer systems is showing a trend of diversification, miniaturization and multi-levelization, and plays an increasingly important role in industrial sites and...
songbo Embedded System
Thinking about code relocation
[color=#FF0000][b]Thoughts on code relocation (1)----PC base address jump[/b][/color] The so-called code relocation is to move the executable code to another address in the memory. The OS usually copi...
zhaohepi Embedded System
Seven speed regulation methods for three-phase asynchronous motors
The speed formula of three-phase asynchronous motor is: n=60f/p(1-s) As can be seen from the above formula, changing the power supply frequency f, the number of pole pairs of the motor p and the slip ...
wanggq Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 920  956  52  1815  2088  19  20  2  37  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号