EEWORLDEEWORLDEEWORLD

Part Number

Search

CB21410307EB

Description
30 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK
CategoryThe connector    terminals   
File Size265KB,5 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

CB21410307EB Overview

30 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK

CB21410307EB Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Fastening methodSCREW
Manufacturer's serial numberCB2000
Installation typeBOARD
Number of layers1
Rows1
Number of channels3
Rated current30 A
Rated voltage300 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
Terminal Blocks - Single Row
Terminal Blocks:
Single & Double Row
Series A2000, LP2000 & CB2000
Single Row Terminal Blocks
A20510807WR
Terminal Blocks:
Base & Rail Mount
SPECIFICATIONS
Rating:
A2: 30A, 300V*
LP2: 30A, 150V*
CB2: 30A, 300V*
Center Spacing:
0.375” or 3/8” (9.52mm)
Wire Range:
#12-22 AWG CU
Screw Size:
#6-32 zinc-plated philslot
LP202110
Torque Rating:
9 lb-in.
Base:
Standoffs standard for easy flux washing
Distance Between Barriers:
0.32” (8.1mm)
Recommended PCB Hole Diameter:
0.076” (1.93mm)
Operating Temperature:
105°C (221°F) max., -40°C (-40°F) min.
Molded Material:
Black, UL Rated 94V0 Thermoplastic
Breakdown Voltage:
3400V (A2 & LP2); 4100V (CB2).
Agency Information:
UL File E62622, CSA File 47235;
IEC Compliance; CE Certified
EuroMag Series
CB20210507
*30A Rating achieved with a #10 copper wire crimped to a ring terminal.;
20A Rating without ring terminal.
Dimensions - in (mm)
A2000 & LP2000 Series
Power Distribution
Blocks
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
MOUNTING
ENDS
ONLY
A
C
Mount Ctrs.
Length
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
1.56
1.93
2.30
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.69
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.56
10.93
11.31
11.68
12.05
BARRIER &
MOUNTING
ENDS
B
Pole Ctrs.
0.38
0.75
1.13
1.50
1.88
2.25
2.63
3.00
3.38
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
BARRIER
ENDS
ONLY
C
Length
0.81
1.18
1.56
1.93
2.31
2.68
3.06
3.43
3.81
4.18
4.56
4.93
5.31
5.68
6.06
6.43
6.81
7.18
7.56
7.93
8.31
8.68
9.06
9.43
9.81
10.18
10.55
10.93
11.31
11.68
12.05
0.375
(9.53)
0.15
(3.8)
Ø
0.65
(16.5)
C
Mount End
Barrier End
0.76 (19.3)
0.40
(10.2)
0.565 (14.35)
on LP2000
Wire Management
Products
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
0.02
(0.5)
CB2000 Series
0.375
(9.53)
0.19
(4.8)
Ø
0.32
(8.1)
0.70
(17.8)
Edge Connectors,
One-Sided Boards
C
Mount End
Barrier End
* Dimensions in inches. To convert to millimeters, multiply by 25.4.
0.60
(15.2)
Compliance
References
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
0.02
(0.5)
6
For additional product information, visit www.cooperbussmann.com/magnum
2014 Shenzhen Maker Fair--Fun
I am a TI supporter. I have received many TI awards and boards, as well as many chips I applied for during college. Thank you! So of course I will start with the TI boards. I will not introduce what t...
IC爬虫 Talking
Easy Power Supply
What does Yidian Power's external frequency tracking mean? I just watched a video, and it said that the LM2Z23605 series can track the external frequency. What is this external frequency used for?...
billjing Analogue and Mixed Signal
Looking for pads95 learning materials and videos!
I have always used AD to draw schematics and PCBs. Because of a job change, the new company uses PADS95. So, I am looking for learning materials and videos of pads95. I also hope that seniors and mast...
yhye2world PCB Design
The difference between ordinary motors, stepper motors and servo motors
[b]The ordinary motors, stepper motors, and servo motors mentioned here refer to direct current micro motors. Most of the motors we come into contact with are direct current motors. The knowledge of m...
qwqwqw2088 Robotics Development
What is the relationship between the HFE value of a transistor and its amplification factor?
Need some advice from an expert, what is the relationship between the HFE value of a transistor and its amplification factor? Thanks...
雨露 Power technology
[GD32L233C-START Evaluation] 2. Keil development environment construction
[i=s]This post was last edited by dql2016 on 2022-1-15 12:27[/i]GD32L233C supports keil and IAR development IDE. I use the familiar keil here. I originally planned to go to the keil official website t...
dql2016 GD32 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2419  579  2669  1611  2091  49  12  54  33  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号