EEWORLDEEWORLDEEWORLD

Part Number

Search

BK/MDL-3/16V

Description
Electric Fuse, Time Delay Blow, 0.188A, 250VAC, 35A (IR), Through Hole, AXIAL LEADED
CategoryCircuit protection    Circuit protection   
File Size98KB,2 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

BK/MDL-3/16V Overview

Electric Fuse, Time Delay Blow, 0.188A, 250VAC, 35A (IR), Through Hole, AXIAL LEADED

BK/MDL-3/16V Parametric

Parameter NameAttribute value
MakerCooper Industries
package instructionAXIAL LEADED
Reach Compliance Codeunknown
ECCN codeEAR99
Fusing characteristicsTIME DELAY
body height32.82 mm
Body length or diameter6.76 mm
Circuit protection typeELECTRIC FUSE
JESD-609 codee3
Joule integral nominal
Manufacturer's serial numberMDL
Installation featuresTHROUGH HOLE
method of packingBOX
physical size6.76mm x 32.82mm
Rated breaking capacity35 A
Rated current0.188 A
Rated voltage (AC)250 V
GuidelineCSA; UL
surface mountNO
Terminal surfaceTIN
Terminal shapePIN WIRE
1/4" x 1-1/4" Fuses
MDL Series, Time Delay, Glass Tube
Description
• Time delay, glass tube
• Optional axial leads available
• 1/4 x 1-1/4 (6.3mm x 32mm) physical size
• Glass tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
Rated Current
Amp Rating
Opening Time
100%
None
1/16 - 30A
135%
60 minutes max.
200%
120 seconds max.
1/16 - 3A
200%
5 seconds min.
3-2/10 - 8A
200%
12 seconds min.
RoHS
2002/95/EC
Dimensions
(
mm
in
)
Drawing Not to Scale
Agency Information
• UL Listed Card: MDL 1/16 - 8A (Guide JDYX, File E19180)
• UL Recognized Card: MDL 9 - 30A (Guide JDYX2,
File E19180)
• CSA Certification Card: MDL 1/16 - 8A
(Class No. 1422-01)
• CSA Component Acceptance: MDL 9-30A
(Class No. 1422-30)
Environmental Data
• Shock: 1/100A and 8/10A – MIL-STD-202,
Method 213, Test Condition I; 1A thru 30A –
MIL-STD-202, Method 207, (HI Shock)
• Vibration: 1/100A and 8/10A – MIL-STD-202,
Method 201; 1/4A thru 30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
Voltage
Rating
AC
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
32V
32V
32V
32V
32V
32V
AC Interrupting
Rating*
125V
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
-
-
-
-
-
-
SPECIFICATIONS
32V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1000A
1000A
1000A
1000A
1000A
1000A
Product Code
MDL-1/16
MDL-1/10
MDL-1/8
MDL-3/16
MDL-2/10
MDL-1/4
MDL-3/10
MDL-3/8
MDL-1/2
MDL-3/4
MDL-1
MDL-1-1/4
MDL-1-1/2
MDL-2
MDL-2-1/4
MDL-2-1/2
MDL-3
MDL-4
MDL-5
MDL-6
MDL-6-1/4
MDL-7
MDL-8
MDL-9
MDL-10
MDL-15
MDL-20
MDL-25
MDL-30
*
**
Traditional Ferrule Fuses - Ferrule Type
250V
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
100A
100A
100A
100A
100A
100A
200A
200A
200A
200A
200A
200A
-
-
-
-
-
-
Typical DC Cold
Resistance**
(ohms)
38.000
15.900
9.850
4.680
4.115
3.200
2.300
2.800
1.725
0.822
0.525
0.320
0.250
0.173
0.068
0.096
0.067
0.035
0.023
0.018
0.018
0.018
0.011
0.009
0.008
0.006
0.002
0.001
0.001
Typical
Melting I
2
t†
AC
0.0046
0.0420
0.0422
0.116
0.314
0.447
0.412
0.982
1.656
4.343
11.498
86.2
22.7
62.3
49.6
63.1
67.5
19.3
32.0
37.4
38.7
42.7
47.8
51.5
64.4
354.0
2914.0
15221.0
15581.0
Typical
Voltage
Drop‡
2.79
1.95
1.52
1.05
0.972
0.965
0.808
1.46
1.27
1.01
0.995
0.722
0.721
0.644
0.535
0.410
0.345
0.187
0.160
0.155
0.152
0.140
0.119
0.124
0.114
0.130
0.530
0.30
0.40
Interrupting Ratings (Interrupting ratings were measured at 70% - 80% power factor on AC)
DC Cold Resistance (Measured at
≤10%
of rated current)
Typical Melting I
2
t (A
2
Sec) (I
2
t was measured at listed interrupting rating and rated voltage.)
Typical Voltage Drop (Voltage drop was measured at 25°C±3°C ambient temperature at rated current)
OC-88
What is the difference between characteristic impedance and input and output impedance?
[i=s]This post was last edited by dontium on 2015-1-23 13:24[/i]There are requirements for the characteristic impedance of the attenuator in high-frequency circuits. Is the characteristic impedance of...
jassica8888 Analogue and Mixed Signal
Who has information about umc6538?
Does anyone have the information about umc6538? You can use the cracked version of KingView to exchange. (The network version supports 1000 users)...
songyue504 Embedded System
When to use analog temperature sensor chips and when to use digital temperature sensor chips
[i=s] This post was last edited by shijizai on 2018-6-5 09:10 [/i] When do you use analog temperature sensor chips and when do you use digital temperature sensor chips? Are there any differences betwe...
shijizai Discrete Device
Comparison of the skills of embedded software engineers and Chinese martial arts
1. Acupuncture: Have an in-depth understanding of the architecture of at least one processor/controller and be familiar with its assembly instructions. 2. Skills: Proficient in C language, master load...
tiankai001 MCU
How to minimize a dialog-based MFC program under evc 2003
After running a dialog-based MFC program under EVC 2003, it cannot be minimized and the Today interface cannot be viewed. The same is true when downloading the examples in the SDK. If the dialog windo...
liaohuchen Embedded System
51 Read DS18b20 temperature
...
pontiff 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2524  807  1418  2814  76  51  17  29  57  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号