EEWORLDEEWORLDEEWORLD

Part Number

Search

BK8/MDL-1/8B

Description
TIME DELAY BLOW ELECTRIC FUSE, 0.125A, 250VAC, 35A (IR), INLINE/HOLDER
CategoryCircuit protection    Circuit protection   
File Size106KB,2 Pages
ManufacturerEaton
Download Datasheet Parametric View All

BK8/MDL-1/8B Overview

TIME DELAY BLOW ELECTRIC FUSE, 0.125A, 250VAC, 35A (IR), INLINE/HOLDER

BK8/MDL-1/8B Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codeunknown
Fusing characteristicsTIME DELAY
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal
Manufacturer's serial numberMDL
Installation featuresINLINE/HOLDER
method of packingBOX
physical size6.35mm x 31.75mm
Rated breaking capacity35 A
Rated current0.125 A
Rated voltage (AC)250 V
GuidelineCSA; UL
surface mountNO
Terminal surfaceNICKEL
Terminal shapeEND CAP
1/4" x 1-1/4" Fuses
MDL Series, Time Delay, Glass Tube
Description
• Time delay, glass tube
• Optional axial leads available
• 1/4 x 1-1/4 (6.3mm x 32mm) physical size
• Glass tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
Amp Rating
Opening Time
Rated Current
100%
None
1/16 - 30A
135%
60 minutes max.
200%
120 seconds max.
1/16 - 3A
200%
5 seconds min.
3-2/10 - 8A
200%
12 seconds min.
RoHS
2002/95/EC
Dimensions
(
mm
in
)
Drawing Not to Scale
Agency Information
• UL Listed Card: MDL 1/16 - 8A (Guide JDYX, File E19180)
• UL Recognized Card: MDL 9 - 30A (Guide JDYX2,
File E19180)
• CSA Certification Card: MDL 1/16 - 8A
(Class No. 1422-01)
• CSA Component Acceptance: MDL 9-30A
(Class No. 1422-30)
Environmental Data
• Shock: 1/100A and 8/10A – MIL-STD-202,
Method 213, Test Condition I; 1A thru 30A –
MIL-STD-202, Method 207, (HI Shock)
• Vibration: 1/100A and 8/10A – MIL-STD-202,
Method 201; 1/4A thru 30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
SPECIFICATIONS
Product Code
MDL-1/16
MDL-1/10
MDL-1/8
MDL-3/16
MDL-2/10
MDL-1/4
MDL-3/10
MDL-3/8
MDL-1/2
MDL-3/4
MDL-1
MDL-1-1/4
MDL-1-1/2
MDL-2
MDL-2-1/4
MDL-2-1/2
MDL-3
MDL-4
MDL-5
MDL-6
MDL-6-1/4
MDL-7
MDL-8
MDL-9
MDL-10
MDL-15
MDL-20
MDL-25
MDL-30
*
**
Traditional Ferrule Fuses - Ferrule Type
Voltage
Rating
AC
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
32V
32V
32V
32V
32V
32V
250V
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
100A
100A
100A
100A
100A
100A
200A
200A
200A
200A
200A
200A
-
-
-
-
-
-
AC Interrupting
Rating*
125V
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
-
-
-
-
-
-
32V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1000A
1000A
1000A
1000A
1000A
1000A
Typical DC Cold
Resistance**
(ohms)
38.000
15.900
9.850
4.680
4.115
3.200
2.300
2.800
1.725
0.822
0.525
0.320
0.250
0.173
0.068
0.096
0.067
0.035
0.023
0.018
0.018
0.018
0.011
0.009
0.008
0.006
0.002
0.001
0.001
Typical
Melting I
2
t†
AC
0.0046
0.0420
0.0422
0.116
0.314
0.447
0.412
0.982
1.656
4.343
11.498
86.2
22.7
62.3
49.6
63.1
67.5
19.3
32.0
37.4
38.7
42.7
47.8
51.5
64.4
354.0
2914.0
15221.0
15581.0
Typical
Voltage
Drop‡
2.79
1.95
1.52
1.05
0.972
0.965
0.808
1.46
1.27
1.01
0.995
0.722
0.721
0.644
0.535
0.410
0.345
0.187
0.160
0.155
0.152
0.140
0.119
0.124
0.114
0.130
0.530
0.30
0.40
Interrupting Ratings (Interrupting ratings were measured at 70% - 80% power factor on AC)
DC Cold Resistance (Measured at
≤10%
of rated current)
Typical Melting I
2
t (A
2
Sec) (I
2
t was measured at listed interrupting rating and rated voltage.)
Typical Voltage Drop (Voltage drop was measured at 25°C±3°C ambient temperature at rated current)
OC-94
【TI Technical Article】: Using TI multi-standard base station SoC to achieve comprehensive improvement in performance, efficiency and differentiation
Since the advent of wireless networks, data throughput has grown rapidly, and the demand for mobile network capacity has also increased. Long Term Evolution ( 4G LTE ) provides higher spectral efficie...
德仪DSP新天地 DSP and ARM Processors
Analysis and design of embedded DDR information line routing
[b]Introduction[/b] Embedded DDR (Double Data Rate) design is the most important and core part of embedded hardware design with DDR. As the processing power of embedded systems becomes more and more p...
程序天使 Embedded System
A strange phenomenon (solved)
I learned the MSP430 teaching video in the TI classroom some time ago, and was fortunate to get an MSP430LaunchPad development board. Today I wanted to try the buttons. The program I wrote was very si...
千里千寻 Microcontroller MCU
An SI engineer who does not understand processing cannot be called Mr. High Speed
Author: Huang Gang, a member of Yibo Technology Expressway MediaSimulation is the simulation of PCB design, and PCB design is the design used for processing and production. As the error factors brough...
yvonneGan PCB Design
EEWORLD University Hall----Live Replay: Use ModusToolbox? to build a system to flexibly respond to IoT design challenges
Live replay: Use ModusToolbox? to build a system to flexibly meet IoT design challenges : https://training.eeworld.com.cn/course/5777...
hi5 Talking
Capacitor decoupling principle
[align=left]Transferred from QQ Space[/align][align=left][font=宋体][color=#000000][size=15.3333px]Author: Bingyang[/size][/color][/font][/align] [align=left]Using capacitor decoupling is the main metho...
okhxyyo Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 407  668  74  1686  1695  9  14  2  34  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号