EEWORLDEEWORLDEEWORLD

Part Number

Search

BK8/MDL-9V

Description
Electric Fuse, Time Delay Blow, 9A, 32VAC, 1000A (IR), Through Hole
CategoryCircuit protection    Circuit protection   
File Size98KB,2 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

BK8/MDL-9V Overview

Electric Fuse, Time Delay Blow, 9A, 32VAC, 1000A (IR), Through Hole

BK8/MDL-9V Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Fusing characteristicsTIME DELAY
body height32.82 mm
Body length or diameter6.76 mm
Circuit protection typeELECTRIC FUSE
JESD-609 codee3
Joule integral nominal51 J
Manufacturer's serial numberMDL
Installation featuresTHROUGH HOLE
method of packingBOX
physical size6.76mm x 32.82mm
Rated breaking capacity1000 A
Rated current9 A
Rated voltage (AC)32 V
GuidelineCSA; UL
surface mountNO
Terminal surfaceTIN
Terminal shapePIN WIRE
1/4" x 1-1/4" Fuses
MDL Series, Time Delay, Glass Tube
Description
• Time delay, glass tube
• Optional axial leads available
• 1/4 x 1-1/4 (6.3mm x 32mm) physical size
• Glass tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
Rated Current
Amp Rating
Opening Time
100%
None
1/16 - 30A
135%
60 minutes max.
200%
120 seconds max.
1/16 - 3A
200%
5 seconds min.
3-2/10 - 8A
200%
12 seconds min.
RoHS
2002/95/EC
Dimensions
(
mm
in
)
Drawing Not to Scale
Agency Information
• UL Listed Card: MDL 1/16 - 8A (Guide JDYX, File E19180)
• UL Recognized Card: MDL 9 - 30A (Guide JDYX2,
File E19180)
• CSA Certification Card: MDL 1/16 - 8A
(Class No. 1422-01)
• CSA Component Acceptance: MDL 9-30A
(Class No. 1422-30)
Environmental Data
• Shock: 1/100A and 8/10A – MIL-STD-202,
Method 213, Test Condition I; 1A thru 30A –
MIL-STD-202, Method 207, (HI Shock)
• Vibration: 1/100A and 8/10A – MIL-STD-202,
Method 201; 1/4A thru 30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
Voltage
Rating
AC
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
32V
32V
32V
32V
32V
32V
AC Interrupting
Rating*
125V
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
-
-
-
-
-
-
SPECIFICATIONS
32V
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1000A
1000A
1000A
1000A
1000A
1000A
Product Code
MDL-1/16
MDL-1/10
MDL-1/8
MDL-3/16
MDL-2/10
MDL-1/4
MDL-3/10
MDL-3/8
MDL-1/2
MDL-3/4
MDL-1
MDL-1-1/4
MDL-1-1/2
MDL-2
MDL-2-1/4
MDL-2-1/2
MDL-3
MDL-4
MDL-5
MDL-6
MDL-6-1/4
MDL-7
MDL-8
MDL-9
MDL-10
MDL-15
MDL-20
MDL-25
MDL-30
*
**
Traditional Ferrule Fuses - Ferrule Type
250V
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
100A
100A
100A
100A
100A
100A
200A
200A
200A
200A
200A
200A
-
-
-
-
-
-
Typical DC Cold
Resistance**
(ohms)
38.000
15.900
9.850
4.680
4.115
3.200
2.300
2.800
1.725
0.822
0.525
0.320
0.250
0.173
0.068
0.096
0.067
0.035
0.023
0.018
0.018
0.018
0.011
0.009
0.008
0.006
0.002
0.001
0.001
Typical
Melting I
2
t†
AC
0.0046
0.0420
0.0422
0.116
0.314
0.447
0.412
0.982
1.656
4.343
11.498
86.2
22.7
62.3
49.6
63.1
67.5
19.3
32.0
37.4
38.7
42.7
47.8
51.5
64.4
354.0
2914.0
15221.0
15581.0
Typical
Voltage
Drop‡
2.79
1.95
1.52
1.05
0.972
0.965
0.808
1.46
1.27
1.01
0.995
0.722
0.721
0.644
0.535
0.410
0.345
0.187
0.160
0.155
0.152
0.140
0.119
0.124
0.114
0.130
0.530
0.30
0.40
Interrupting Ratings (Interrupting ratings were measured at 70% - 80% power factor on AC)
DC Cold Resistance (Measured at
≤10%
of rated current)
Typical Melting I
2
t (A
2
Sec) (I
2
t was measured at listed interrupting rating and rated voltage.)
Typical Voltage Drop (Voltage drop was measured at 25°C±3°C ambient temperature at rated current)
OC-88
About the dynamic display problem of triode driving digital tube
The STC89C51 microcontroller P0 outputs the segment selection signal , and P2 is the bit selection. The transistor used is 8050, and the common cathode digital tube. The P0 output is connected to a 20...
eeleader-mcu MCU
!!! When an interrupt occurs, does the interrupt handler run in the system thread? ? ? ?
For example, if the system is Win2K, when a device generates an interrupt, is the current thread terminated, and then the system thread takes ownership and calls the interrupt handler? ?...
zjhzlswxh Embedded System
How to Design a Simple Constant Current/Constant Voltage Buck Converter
Sharing a design by David Baba. Introduction DC-DC converters are often implemented as constant voltage (CV) regulators. The control loop will adjust the duty cycle so that a constant output voltage i...
alan000345 Analogue and Mixed Signal
About 100V High Withstand Voltage Step-Down IC
SC9902 is a high performance, high precision, low cost step-down constant voltage and constant current controller with adjustable output voltage of 5-26V, suitable for non-isolated step-down applicati...
mk015 Mobile and portable
About the use of msp430 firmware library
When I use the driverlib of MSP430F5xx_6xx, an error will be reported when calling #include "timer_a.c". The errors are as follows: Error[Pe020]: identifier "OFS_TAxCTL" is undefined F:\driverlib\MSP4...
fymok Microcontroller MCU
How to use 51 single chip microcomputer to generate RS422 pulse?
I now have a sensor that outputs 25-bit digital quantities, but these 25 digits need to be sent in time-sharing under the excitation of 25 pulse rise delays. The interval between each rise delay is le...
dfx168 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 251  238  1540  438  613  6  5  32  9  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号