EEWORLDEEWORLDEEWORLD

Part Number

Search

F.BQ.MA.2100.ZF.100

Description
Mains Power Connector, 6A, 250V, Male, Solder Terminal, Plug
CategoryThe connector    The connector   
File Size504KB,2 Pages
ManufacturerNissei Electric Co.,Ltd.
Download Datasheet Parametric View All

F.BQ.MA.2100.ZF.100 Overview

Mains Power Connector, 6A, 250V, Male, Solder Terminal, Plug

F.BQ.MA.2100.ZF.100 Parametric

Parameter NameAttribute value
MakerNissei Electric Co.,Ltd.
Reach Compliance Codeunknown
Other featuresSTANDARD: IEC/EN 60320; VDE, FASTON
Body/casing typePLUG
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeSCREW
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings6A, 250V
Manufacturer's serial numberF.BQ
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
IEC Inlet Filters
With fuse holders
A range of chassis mount IEC 60320 inlet power entry modules which
combine single or twin fuse holders and a high level of suppression,
within a compact and lightweight enclosure.
Cost effective solution for business, consumer, medical
equipment, VDUs, computers, vending machines and many other
general purpose applications.
F.BP-F.BQ-F.CP-F.CQ
series
Snap-in or screw fit
Current ratings from 1A to 10A
Integral single or twin fuse holder
Compact, lightweight design
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320 & EN 60320 and fuse
holder for 1 (F.-P) or 2 (F.-Q) fuses 5 x 20mm (IEC).
Connections:
IEC 60320 - Standard plug (INPUT);
faston 2x2.8 x 0.5mm or 6.3 x 0.8mm (OUTPUT);
ground terminal connected to case.
Mounting:
F.B- screw mounting, F.C- Snap-in mounting.
Climatic category:
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21):
Temperature range: -25°C to +85°C
Leakage current (I
L
):
at 220V, 50Hz, max value
Filter Range
Code
F.--.AB.2680.ZA.100
F.--.AB.2680.ZB.100
F.--.AB.2680.ZC.100
F.--.AB.2680.ZF.100
F.--.AB.2680.ZG.100
I
R
(A)
1
2
4
6
10
L
(mH)
2x10
2x4
2x1.5
2x0.8
2x0.13
Cx
1
(µF)
0.068
0.068
0.068
0.068
0.068
Cy
(pF)
2x2200
2x2200
2x2200
2x2200
2x2200
I
L
(mA)
2x0.2
2x0.2
2x0.2
2x0.2
2x0.2
Circuit diagram
Only for F.BQ and F.CQ
Available Variants
B = Screw mounting
C = Snap-in mounting
A = Standard Version
M = Medical Version
I
R
, L & CCT.
CCT A VALUES
ZA
1A, 10mH,
ZB
2A, 4mH,
ZC
4A, 1.5mH
ZF
6A, 0.8mH
ZG
10A, 0.13mH
P = Single Fuse
Q = Double Fuse
X Capacitance
2100 = 0.010uF
2470 = 0.047uF
2680 = 0.068uF
3100 = 0.1uF
F. --.-- - - - -. - -. - - 0
A = 2x2.8mm x 0.8 faston
B = 6.3mm x 0.8 faston
Y Capacitance
0 = 2500pF
1 = 2200pF
2 = RESERVED
3 = RESERVED
4 = 150pF
Current Leakage
2x0.23 mA
2x0.20 mA
2x0.014 mA
Resistor
0 = no resistor
1 = 1MΩ
2 = 2.2MΩ
Approvals
24
eeworld group purchase activity ADS8332 chip small test resources
eeworld group purchase chip small test resources [color=rgb(7, 81, 154)][font=Helvetica, Tahoma, Arial, sans-serif][size=18px][url=https://download.eeworld.com.cn/detail/%E8%93%9D%E9%9B%A8%E5%A4%9C/16...
蓝雨夜 Analogue and Mixed Signal
The basic working principle of human infrared sensor
[color=#222222][backcolor=rgb(238, 238, 238)][font=sans-serif]As shown in the figure, the basic working principle of the human infrared sensor. [/font][/backcolor][/color] [color=#222222][backcolor=rg...
mculpcstm Analog electronics
Today is Father’s Day. I wish all fathers in the world good health, happy family and constant smiles on their faces!
Today is Father's Day. I see there are no blessing posts in this regard in the forum. Also, today is the weekend and everyone is out playing. I wish all the forum members who have lovers a happy Fathe...
fxw451 Talking
How to call msp430 touch software library in IAR
I recently bought an MSP-EXP430G2 LaunchPad development board and used IAR for development. The touch function requires downloading the touch library from the official website. After downloading it, I...
LFlyming Microcontroller MCU
Have you ever used the GP8706 IC?
Have youever used this IC GP8706? If so, please send me the information. Thank you! ! !...
wudi0109 Power technology
How to write data to the specified FLASH address? Thank you
How to write data to the specified FLASH address? Thank you...
zllka stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1170  2510  624  871  653  24  51  13  18  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号