EEWORLDEEWORLDEEWORLD

Part Number

Search

86010S-E-2PD

Description
MIL Series Connector, 39 Contact(s), Steel, Male, Crimp Terminal, Receptacle
CategoryThe connector    The connector   
File Size65KB,1 Pages
ManufacturerHiRel Connectors Inc
Websitehttps://hirelco.net
Download Datasheet Parametric View All

86010S-E-2PD Overview

MIL Series Connector, 39 Contact(s), Steel, Male, Crimp Terminal, Receptacle

86010S-E-2PD Parametric

Parameter NameAttribute value
MakerHiRel Connectors Inc
Reach Compliance Codeunknown
Other featuresSTANDARD: MIL-DTL-38999
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsCORROSION RESISTANT; ENVIRONMENT RESISTANT; FLUID RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Manufacturer's serial number86010
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsYES
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceNICKEL PLATED
Shell materialSTEEL
Housing sizeE
Termination typeCRIMP
Total number of contacts39
D38999/24
Jam Nut Mount Environment Resistant Receptacle
MIL-DTL-38999
Series III – Threaded Coupling
NOTES:
1. PANEL THICKNESS .126/.050 [3.20/1.58]
2. CONNECTOR CONTAINS REQUIRED FEATURES FOR
PROPER FIT IN A TYPE "E" PANEL
3. FOR CONNECTOR COMPONENTS AND ACCESSOROES,
SEE PAGE C-5
ØA
2 PLCS
1.279 [32.5]
MAX
.889 [22.6] MAX.
.519/.500 [13.2/12.7]
(FULLY MATED INDICATOR
BAND - RED)
S
P
SEE CONTACT
STYLE
DESIGNATOR
ON ORDERING
INFORMATION
PAGE
B Flat
BB Thd
G Thd
O-Ring
W
VV Thd
SHELL SHELL
SIZE
SIZE CODE
9
11
13
15
17
19
21
23
25
A
B
C
D
E
F
G
H
J
ØA
±.011
[±0.3]
1.189 [30.2]
1.374 [34.9]
1.500 [38.1]
B Flat BB Thd G Thd
CLASS 2A
+.004/-.006
[+0.10/-0.15] 0.1P-0.3L-TS
.651 [16.53]
.751 [19.07]
.938 [23.82]
.6250
.7500
.8750
1.0000
1.1875
1.2500
1.3750
1.5000
1.6250
M17 x 1.0
M20 x 1.0
M25 x 1.0
M28 x 1.0
*M32 x 1.0
M35 x 1.0
M38 x 1.0
M41 x 1.0
M44 x 1.0
P
S
±.016
[±0.4]
VV Thd
-6g 0.100R
M12 x 1.0
M15 x 1.0
M18 x 1.0
M22 x 1.0
M25 x 1.0
M28 x 1.0
M31 x 1.0
M34 x 1.0
M37 x 1.0
W
+.035/-.004
[+0.9/-0.1]
.087 [2.2]
.087 [2.2]
.087 [2.2]
.087 [2.2]
.087 [2.2]
.118 [3.0]
.118 [3.0]
.118 [3.0]
.118 [3.0]
-6g 0.100R +.024/-.000
[+0.6/-0.0]
.555 [14.1] 1.063 [27.0]
.555 [14.1] 1.252 [31.8]
.555 [14.1] 1.374 [34.9]
.555 [14.1] 1.500 [38.1]
.555 [14.1] 1.626 [41.3]
.555 [14.1] 1.811 [46.0]
.555 [14.1] 1.937 [49.2]
.555 [14.1] 2.063 [52.4]
.555 [14.1] 2.189 [55.6]
1.626 [41.3] 1.062 [26.97]
1.752 [44.5] 1.187 [30.15]
1.937 [49.2] 1.312 [33.32]
2.063 [52.4] 1.437 [36.50]
2.189 [55.6] 1.562 [39.67]
2.311 [58.7] 1.687 [42.85]
* = MODIFIED MAJOR DIA. 1.258/1.252 [31.95/31.80]
DIMENSIONS ARE IN INCHES [MILLIMETERS]
United States
– 760 W. Wharton Drive, Claremont CA. 91711
Ph: 909-626-1820
FAX: 909-399-0626
Web:
www.HIRELCO.com
Europe
– 5 Rue Des Longues Raies, Z.I. Des Garennes, 78440; Gargenville, France
Ph: 33(0) 1-309-38999 or U.K. 44(0)1-980-843887
FAX 33(0) 1-309-38913
Web:
www.HIRELCO.com
C-16
Reprinted TI TPS series naming rules
TPS7XXXX: linear regulators and LDOs; TPS40K: medium to high power DC/DC controllers; TPS54XXX: medium power DC/DC controllers; TPS62XXX: low power step-down DC/DC controllers; TPS61XXX: low power ste...
blink Analogue and Mixed Signal
AD PCB3D imports 3D PCB display errors - [Solved]
[i=s]This post was last edited by FantasyTG on 2020-8-18 10:45[/i]Importing 3D PCB error as shown belowDetails: Company version AD6 (older versionAccording to the online suggestion, import the 3D mode...
FantasyTG PCB Design
It's time to say goodbye to discrete solutions for automotive lighting!
[align=left][color=rgb(85, 85, 85)]Major automakers are using light-emitting diodes (LEDs) extensively, in addition to traditional headlights, taillights, daytime running lights, parking lights and tu...
okhxyyo Analogue and Mixed Signal
How to set the IP address of the target machine after startup
The boot mode of the board I use is BIOS+DOS. How can I set the IP address of the target machine after it boots? It is related to the project and I am very anxious. I beg for advice from experts....
mary1127 Embedded System
MSP430: Introduction to the method of programming long data to Flash
Read a long data from RAM address 0x0200 and burn it into Flash at address 0x1800.Code:#include“io430.h”void main(void){//Initialize the pointer of RAM information segmentunsigned long * RAM_ptr = (un...
fish001 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2534  2764  1865  1361  34  52  56  38  28  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号