EEWORLDEEWORLDEEWORLD

Part Number

Search

BK1/S506-500MAS

Description
Electric Fuse, Time Delay Blow, 0.5A, 250VAC, 35A (IR), Inline/holder
CategoryCircuit protection    Circuit protection   
File Size217KB,2 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

BK1/S506-500MAS Overview

Electric Fuse, Time Delay Blow, 0.5A, 250VAC, 35A (IR), Inline/holder

BK1/S506-500MAS Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
Fusing characteristicsTIME DELAY
body height20 mm
Body length or diameter5.2 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal
Manufacturer's serial numberS506
Installation featuresINLINE/HOLDER
method of packingBAG
physical size5.2mm x 20mm
Rated breaking capacity35 A
Rated current0.5 A
Rated voltage (AC)250 V
GuidelineBSI; SEMKO; UL; VDE
surface mountNO
Terminal surfaceNICKEL
Terminal shapeEND CAP
5mm x 20mm Fuses
S506 Series, Time Delay, Glass Tube
Description
• Time delay, low breaking capacity
• 5mm x 20mm physical size
• Glass tube, nickel-plated brass endcap construction
• Optional axial leads are .032" x 1.5" copper tinned
• Optional sleeve is flexible flouropolymer
(U.L. flammability rating VW-1).
• Designed to IEC 60127-2-3
S506 ELECTRICAL CHARACTERISTICS
2.1 In
2.75 In
4 In
10 In
In
max
min
max
min
max
min
max
32mA-100mA 2 min 200 ms 10 sec 40 ms 3 sec 10 ms 300 ms
125mA-6.3A 2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms
8A-12.5A
2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms
Dimensions
Drawing Not to Scale
Ordering
• Specify product code, option code and packaging code
Approvals
• UL Recognized Card: 500mA-6.3A (JDYX2, E75865)
• Semko Approval, 500mA-6.3A
• VDE Approval, 500mA-5A
• BSI Approval, 500mA-6.3A
• IMQ Approval, 800mA-6.3A
• MITI Approval, 1A-6.3A
SPECIFICATIONS
Product Code
S506-500mA
S506-630mA
S506-800mA
S506-1A
S506-1.25A
S506-1.6A
S506-2A
S506-2.5A
S506-3.15A
S506-4A
S506-5A
S506-6.3A
S506-8A
S506-10A
S506-12.5A
Voltage
Rating
AC
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
Interrupting Rating
at Rated Voltage (50Hz)
AC/DC
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
Typical DC
Cold Resistance
(ohms)*
0.268
0.191
0.131
0.064
0.046
0.039
0.029
0.024
0.018
0.013
0.010
0.009
0.007
0.005
0.004
Minimum
Pre-Arching I
2
t
(A
2
Sec) AC†
0.67
1.0
2.2
2.7
6.7
9.7
15
25
51
88
150
214
192
420
812
Maximum
Voltage
Drop (mV)‡
190
170
150
90
85
85
85
85
80
80
75
75
80
75
75
* DC Cold Resistance (Measured at <10% of rated current)
† Minimum Pre-Arching I
2
t (Measured at 10 In and rated voltage)
‡ Maximum Voltage Drop (Voltage drop was measured at 20°C ambient temperature at rated current)

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 34  2784  2219  703  2579  1  57  45  15  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号