EEWORLDEEWORLDEEWORLD

Part Number

Search

D3V-11-3C25-K

Description
Snap Acting/Limit Switch, SPST, Momentary, 11A, 8VDC, 2.2mm, Quick Connect Terminal, Plunger Actuator, Panel Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size1MB,14 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance  
Download Datasheet Parametric View All

D3V-11-3C25-K Overview

Snap Acting/Limit Switch, SPST, Momentary, 11A, 8VDC, 2.2mm, Quick Connect Terminal, Plunger Actuator, Panel Mount, ROHS COMPLIANT

D3V-11-3C25-K Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerOMRON
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator stroke2.2 mm
Actuator typePLUNGER
body width10.3 mm
body height15.9 mm
Body length or diameter27.8 mm
Contact (AC) maximum rated R load11A@250VAC
Maximum contact current (AC)11 A
Maximum contact current (DC)11 A
Contact (DC) maximum rated R load11A@8VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)8 V
Electrical life200000 Cycle(s)
Manufacturer's serial numberD3V
Installation featuresPANEL MOUNT
Maximum operating force1.96 N
Maximum operating temperature105 °C
Minimum operating temperature-25 °C
Maximum pre-travel1.2 mm
sealIP00
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeQUICK CONNECT
Miniature Basic Switch
D3V
Reliable Basic Switch with External Lever
• Available by 0.1 A, 6 A, 11 A, 16 A and 21 A models, all with
self-cleaning contacts. 0.1 A utilizes gold alloy crossbar
contacts for high reliability at low loads.
• Available with internally or externally fitted levers, and 2 fix-
ing positions for external levers.
• Conforms to EN61058-1 UL1054.
• Right-angle plunger option available in some models.
• RoHS Compliant.
Ordering Information
Model Number Legend
D3V-@@@@-@@@-@-@
1 2 3 4
5 6 7
8
9
6. Terminals
A:
Solder/quick-connect terminal (#187)
C2: Quick-connect terminal (#187)
C:
Quick-connect terminal (#250)
(optional without surge creepage tab flush around
terminals.)
7. Maximum Operating Force
5:
1.96 N {200 gf}
4A: 1.23 N {125 gf}
4:
0.98 N {100 gf}
3:
0.49 N {50 gf}
2:
0.25 N {25 gf}
Note:
These values are for the plunger models.
8. Mounting Hole Size
None: 3.1 mm
K:
2.9 mm
9. Special Code
None: Standard
H:
High temperature (125° C)
E:
Special rating: 21 (8) A
T:
High temperature (200
°
C)
1. Ratings
21: 20 (4) A at 250 VAC
16: 16 (3) A at 250 VAC
11: 11 (3) A at 250 VAC
6:
6 (2) A at 250 VAC
01: 0.1 A at 125 VAC
2. Contact Gap
None: 1 mm (F gap)
G:
0.5 mm (G gap)
3. Actuator
None: Pin plunger
1:
Short hinge lever
2:
Hinge lever
3:
Long hinge lever
4:
Simulated roller lever
5:
Short hinge roller lever
6:
Hinge roller lever
4. Hinge Position
None: Internal/Far from plunger
M:
External/Far from plunger
K:
External/Near plunger
5. Contact Form
1:
SPDT
2:
SPST-NC
3:
SPST-NO
Miniature Basic Switch
D3V
1
Serial port output problem
#include #includesbit beep=P3^7;//Buzzer//Alarm program void buz_on(void) { beep = 0; //Turn on the buzzer delay_50ms(10);//Delay 0.5 seconds beep = 1; //Turn off the buzzer } void serial_init(void); ...
zzbeagle Microchip MCU
DIY RF Power Amplifier - Record the whole process
[i=s]This post was last edited by RF-刘海石 on 2018-9-10 11:05[/i] [color=#ff0000][size=5]I haven't written a post here for a long time. I've been either on a business trip or at work recently. I'm too b...
RF-刘海石 RF/Wirelessly
Problems encountered when LCD1602 scroll screen display
I have some small questions during the programming process of the two-line scrolling display of the LCD1602 module. I hope you can help me answer them:congratulate: Thank you everyone. {:1_131:} #incl...
zhr1282 51mcu
Please advise
Can someone explain the meaning of the s parameter? I am a little confused. Thank you....
Johnwu Analog electronics
Do you understand the applications of 0 ohm resistors, magnetic beads, and inductors?
010 ohm resistor0 ohm resistors are often seen in circuit design, and people are often confused: since it is a 0 ohm resistor, it is a wire, why do we need to install it? Are there any such resistors ...
我是病猫 Energy Infrastructure?
Digital frequency meter design
[i=s] This post was last edited by paulhyde on 2014-9-15 09:49 [/i] Can anyone tell me where I can find relevant information on the design of a digital frequency meter? ? The requirement is to use chi...
shengxi_jj Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1032  62  448  781  2264  21  2  10  16  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号