89882-441H

Description
Board Connector, 41 Contact(s), 1 Row(s), Female, Right Angle, 0.1 inch Pitch, Solder Terminal, Locking, Gray Insulator, Receptacle,
File Size72KB,2 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Download Datasheet Parametric View All

89882-441H Overview

Board Connector, 41 Contact(s), 1 Row(s), Female, Right Angle, 0.1 inch Pitch, Solder Terminal, Locking, Gray Insulator, Receptacle,

89882-441H Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Objectid2039455101
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL6.83
body width0.13 inch
subject depth0.334 inch
body length4.097 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedTin/Lead (Sn/Pb)
Contact point genderFEMALE
Contact materialNOT SPECIFIED
contact modeRECTANGULAR
Contact resistance15 mΩ
Contact styleSQ PIN-SKT
DIN complianceNO
Dielectric withstand voltage1400VAC V
Durability225 Cycles
Filter functionNO
IEC complianceNO
maximum insertion force1.5012 N
Insulation resistance100000000000 Ω
Insulator colorGRAY
insulator materialGLASS FILLED POLYETHYLENE
JESD-609 codee0
MIL complianceNO
Plug contact pitch0.1 inch
Mixed contactsNO
Installation option 1LOCKING
Installation methodRIGHT ANGLE
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded1
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
OptionsGENERAL PURPOSE
PCB contact patternRECTANGULAR
PCB contact row spacing7.62 mm
Plating thickness197u inch
polarization keyPOLARIZED HOUSING
Rated current (signal)3 A
GuidelineUL, CSA
Terminal length0.114 inch
Terminal pitch2.54 mm
Termination typeSOLDER
Total number of contacts41
UL Flammability Code94V-0
Evacuation force-minimum value.30024 N
PDM: Rev:J
STATUS:
Released
Printed: Sep 15, 2009
.
If the clamp meter (multimeter) does not measure but there are still numbers, is it a malfunction?
I would like to ask if the clamp meter (multimeter) is faulty if there are still numbers when it is not measuring? It keeps jumping back and forth, sometimes large and sometimes small....
Ablikim Integrated technical exchanges
Set-top box test solution
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 20:01[/i] [table][tr][td][size=9pt][font=Verdana]Set-top box test plan[/font] [font=Verdana]I. Introduction to set-top box test 1. Princip...
songbo Mobile and portable
What is this?
...
白手梦想家 Analog electronics
Ask a question about AD7891 sampling rate
Has anyone used AD7891? The data sheet says that AD7891 can sample up to 500K for one channel, and up to 62.5K for 8 channels. I sample two signals in parallel, but the sampling rate is only a little ...
huabuaa Test/Measurement
AD7656 busy signal is always low! Cannot start
AD7656 chip test, busy signal is always low level, I have tried many methods but can't solve it, two days, urgent!!! Can you help me, I will be grateful. I have also tried the reset signal, and adjust...
jyrhero2015 ADI Reference Circuit
Problems with Protues simulation! Urgent! Please help!
I drew the schematic in proteus, added the .hex file to the chip AT89C52, and started the simulation. Then the following two problems appeared: 1 Node VCC not found whilst binding pin V+ of U3-ADC#002...
daijun20803 Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1850  2711  943  309  354  38  55  19  7  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号