Circular Connector, 4 Contact(s), Stainless Steel, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size317KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

801-010-07Z16-4HD Overview

Circular Connector, 4 Contact(s), Stainless Steel, Female, Crimp Terminal, Receptacle,

801-010-07Z16-4HD Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialSTAINLESS STEEL
Housing size6
Termination typeCRIMP
Total number of contacts4
A
B
C
D
E
F
G
H
J
K
L
-07
Jam Nut for Rear
M
© 2007 Glenair, Inc.
Series 801
Series 801 “Mighty Mouse”
Double-Start ACME Thread
Series 801 Receptacles – Crimp Termination
In-Line
801-009-01
Rear Panel Jam Nut Mount
801-009-07
Square Flange Mount
801-009-02
Integral Band Platform
for direct attachment of a cable
shield using a
BAND-IT®
strap. Install a boot, or overmold
onto the band platform. An accessory thread is available
for attaching strain reliefs and backshells.
Three Shell Options:
Jam nut with o-ring for rear panel
mounting, square flange or in-line receptacle for free-hanging
cables.
HOW TO ORDER
Sample Part Number
80 1- 0 1 0
Series
-02
Shell Style
Z1
Shell Material /
Finish
C
Aluminum / Black
Anodize
16-5 5
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
13-2
13-37
16-55
17-85
3 #23
1 #16
4 #23
7 #23
1 #12
10 #23
13 #23
4 #16
19 #23
26 #23
2 #12
37 #23
55 #23
85 #23
S
Contact Type
A
Shell Key
Position
M
801-009
Receptacle with
Banding Platform
-01
In-Line
Aluminum / Electroless
Nickel
Standard #23 contacts
A
accept #22 through
Normal
#28 AWG wire. Use the
following contact codes
to specify these contacts: Alternate Key
Positions:
P
Pin
NF
Aluminum / Cadmium
with Olive Drab
Chromate
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
B
C
D
ZN
801-010
Receptacle with
Accessory Thread
-02
Square Flange
for Front or Rear
Mounting
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
D-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Please help me guess the chip
8-pin double inline 1.vcc 8 gnd 4 input 3,5 output may be power protection! There are pictures! Contact me for decryption and there will be a red envelope reward! !...
cc05dd Integrated technical exchanges
The first time I played with FPGA applications, I played with the TSL1401 linear array sensor
TSL1401 is a 128-point linear array sensor with a main frequency of up to 8MHz. Some time ago, I drew a board and planned to use FPGA to make it. Almost all the information that can be found about TSL...
littleshrimp Integrated technical exchanges
Problems and solutions encountered when running Network routines on STM32 F7
[i=s] This post was last edited by littleshrimp on 2015-10-14 15:13 [/i] [align=left][font=宋体]I received the board yesterday. According to the instructions of our boss [/font]youki12345[font=宋体], I ra...
littleshrimp stm32/stm8
MKI109V3+MKI182V2 unboxing
MKI109V3+MKI182V2 unboxing test. I just received the goods recently and tested them today. 1. First download the Unico software, link: https://my.st.com/content/my_st_com/en/products/embedded-software...
泉城教师 ST MEMS Sensor Creative Design Competition
ssh, nfs service configuration
1.Configuration of SSH service 1.sudo apt-get install ssh 2. Start the SSH service. /etc/init.d/ssh restart 3. Test the ssh service. If you are not a root user at this time, enter ssh loaclhost, you w...
zhouning201 Linux and Android
Analysis of braking technology for frequency converter
In the traditional variable frequency speed regulation system composed of general frequency converter, asynchronous motor and mechanical load, when the potential load driven by the motor is released, ...
china-power Energy Infrastructure?

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 952  422  1990  310  2340  20  9  41  7  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号