EEWORLDEEWORLDEEWORLD

Part Number

Search

MWDM4L-100P-4J7-18P

Description
D Microminiature Connector, 100 Contact(s), Male, Crimp Terminal,
CategoryThe connector    The connector   
File Size271KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance  
Download Datasheet Parametric View All

MWDM4L-100P-4J7-18P Overview

D Microminiature Connector, 100 Contact(s), Male, Crimp Terminal,

MWDM4L-100P-4J7-18P Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerGlenair
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARD: MIL-DTL-83513
Connector typeD MICROMINIATURE CONNECTOR
Contact to complete cooperationGOLD OVER NICKEL
Contact completed and terminatedGOLD OVER NICKEL
Contact point genderMALE
Contact materialBERYLLIUM COPPER
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
insulator materialGLASS FILLED LIQUID CRYSTAL POLYMER
JESD-609 codee4
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsWITH CABLE ASSEMBLY
Shell surfaceANODIZED BLACK
Shell materialALUMINUM ALLOY
Housing sizeH
Termination typeCRIMP
Total number of contacts100
Micro-D
Harness
Micro-D Metal Shell
MWDM Pre-Wired with Insulated Wire
Micro-D Pre-Wired Pigtails–These
connectors feature
gold-plated TwistPin contacts and mil spec crimp
termination. Specify nickel-plated shells or cadmium
plated shells for best availability. 100% tested and
backpotted, ready for use.
Choose the Wire Type and Size To Fit Your Application–
If on-hand availability is most important, choose #26
AWG Type K mil spec Teflon
®
wire. Select M22759/33
Type J for space applications.
B
HOW TO ORDER METAL SHELL PRE-WIRED MICRO-D CONNECTORS
Shell Material Insulator Contact
Series
and Finish
Material Layout
MWDM
Aluminum Shell
Contact
Type
P
– Pin
S
– Socket
Wire
Gage
(AWG)
4
6
8
0
– #24
– #26
– #28
#30
Wire Type
K
M22759/11
Wire Color
1
White
2
Yellow
5
Color-Coded
Stripes
Per MIL-
STD-681
Wire
Length
Inches Hardware
18
Wire Length
In Inches.
“18” Specifies
18 Inches.
L
– LCP
1
2
4
5
6
– Cadmium
– Nickel
– Black
Anodize
– Gold
– Chem Film
30% Glass-
Filled
Liquid
Crystal
Polymer
Stainless Steel
Shell
3
9
15
21
25
31
37
51
51-2
67
69
100
600 Vrms Teflon
®
(TFE)
J
M22759/33
600 Vrms
Modified Cross-
Linked Tefzel®
(ETFE)
E
NEMA HP3-EB
Passivated
600 VrmsType E
M16878/4 (TFE)
(replaced by
M22759/11 for mil
spec applications)
(Striped wire not
available on 67,
69 or 100 pin
connectors or for
#28, #30 AWG)
7
Ten Color
B
P
M
M1
S
S1
L
K
F
R
H
Repeating
Sample Part Number
MWDM
2
L –
25
S –
4
K
7 –
18
B
B
P
M
M1
MOUNTING HARDWARE
S
S1
L
K
F
R
H
Thru-Hole
Jackpost
Hex Head
Jackscrew
Hex Head
Jackscrew,
Extended
Slot Head
Jackscrew
Slot Head
Jackscrew,
Extended
Hex Head
Jackscrew
Non-
Removable
Slot Head
Jackscrew
Non-
Removable
Extended
Float Mount
For Front
Panel
Mounting
Float Mount
For Rear
Panel
Mounting
Threaded
Insert
© 2011 Glenair, Inc.
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
E-Mail: sales@glenair.com
B-4
What are the measures to cut off interference propagation paths in PCB design?
The interference source refers to the component, device or signal that generates interference; the propagation path refers to the path or medium through which the interference propagates from the inte...
就某个水呀 PCB Design
How to create a VHDL library?
Have you ever created your own VHDL type library? How do you create it? How do you use it?...
eeleader FPGA/CPLD
Please help me, experts. Those who can solve it will get 100 points.
Regarding the problem of DDK compiling driver in Windows 2003 sp1 DDK (Windows DDK 3790.1830), the compilation environment used is Windows XP, and the files are as follows: 1. sources file: TARGETNAME...
liuyuanlei Embedded System
Pseudo-code ranging
Is there any program related to pseudo-code ranging? I need it urgently, for capture and tracking...
笑不动动 FPGA/CPLD
Problems with RegisterClass on Wince6.0
My application failed to start on WINCE6.0. Later I found out that the reason was using the function RegisterClass. RegisterClass is as follows: WNDCLASS wcex; wcex.style = CS_HREDRAW | CS_VREDRAW; wc...
qianyg Embedded System
MSP430 enters low power mode LPM0, uses external interrupt to wake up, where is it after waking up
[size=14.44444465637207px]MSP430 enters low power mode LPM0. After waking up with an external interrupt, I have been single-stepping and debugging. After waking up, it has been stuck at [/size] [code]...
火火山 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2085  268  2264  2757  783  42  6  46  56  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号