Description
Power/Signal Relay, DPDT, Latched, 0.022A (Coil), 48VDC (Coil), 1056mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
CategoryMechanical and electronic products    relay   
File Size153KB,2 Pages
ManufacturerBabcock Inc
Download Datasheet Parametric View All

BR20AX-H1-V4 Overview

Power/Signal Relay, DPDT, Latched, 0.022A (Coil), 48VDC (Coil), 1056mW (Coil), 10A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,

BR20AX-H1-V4 Parametric

Parameter NameAttribute value
MakerBabcock Inc
Reach Compliance Codeunknown
body width13.08 mm
body height33.02 mm
Body length or diameter27.31 mm
Maximum coil current (DC)0.022 A
Coil operating voltage (DC)33 V
Coil power1056 mW
Coil release voltage (DC)24 V
Coil resistance2200 Ω
Maximum coil voltage (DC)48 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load10A@115VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
JESD-609 codee3
Manufacturer's serial numberBR20
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours12 ms
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
physical size27.31mm X 13.08mm X 33.02mm
GuidelineMIL-PRF-39016
Relay actionLATCHED
Relay functionDPDT
Relay typePOWER/SIGNAL RELAY
release time12 ms
surface mountNO
Terminal surfaceTIN
Termination typeSOLDER
BR20
Crystal Can
Welded • DPDT
Magnetic Latching
Dry Circuit to 10 Amps
SPECIFICATIONS
GENERAL
Contact Arrangement
.......................... 2PDT (2 Form C)
Magnetic Latching
Weight.........................................................
1.6 oz approx.
Designed to meet the requirements of MIL-PRF-39016.
PERFORMANCE
Contact Rating
(Note 1)
Resistive .............10 Amps @ 28 VDC or 115V 400 Hz
(Case Ungrounded)
Inductive .......................................3.5 Amps @ 28 VDC
Life
...................................100,000 operations minimum
o
@ rated load, 125 C
Latch/Reset Power:
BR20AX................................................250 mw approx.
BR20BX................................................130 mw approx.
Latch/Reset Time
.......................... 10 ms max, excluding
bounce time at nominal coil voltage
Contact Bounce Time..................
2 ms max @ 10 Amps
28 VDC
Contact Voltage Drop:
Before Life.......................100 mv max @ rated current
6 or 28 VDC
After Life ..........................200 mv max @ rated current
6 or 28 VDC
ENVIRONMENTAL
o
o
Temperature Range
............................... -65 C to +125 C
Vibration
(Note 2)............................... 0.4" DA 10 - 38 Hz,
20 G's 38 - 2,000 Hz
Shock (Operating)
(Note 2) ........................ 50 G's 11 ms
ELECTRICAL CHARACTERISTICS
Duty Cycle........................................................Continuous
Insulation Resistance
o
10,000 megohms @ 500V 25 C
o
1,000 megohms @ 500V 125 C
Dielectric Strength:
Sea Level:
Between Coils (BR20AX) ....................... 500 VRMS
Contact to Case ................................... 1,250 VRMS
Contact to Coil ..................................... 1,250 VRMS
Coil to Case ......................................... 1,000 VRMS
Across Open Contacts ........................ 1,250 VRMS
70,000 Feet
All points.................................................. 500 VRMS
Notes:
1. For case grounded loads and other ratings, consult the
factory.
2.
For applications requiring other shock and vibration
levels, consult the factory.
5.
Contacts were placed in the position shown by placing
voltage with the polarity shown on the indicated coil
(reset). To switch contacts, a voltage of indicated
polarity must be applied to the other coil (Latch).
Contacts were placed in position shown by placing
voltage with the polarity indicated on the coil. To switch
contacts a voltage of the reverse polarity must be
applied to the coil.
6.
3.
4.
For other ratings consult the factory.
Relay contacts which have switched high level currents
are no longer suitable for switching low level loads.
14930 E. Alondra Blvd., La Mirada, CA 90638-5752 (714) 994-6500 FAX (714) 994-3013
W:2000 Rev. 3
There is a problem with the simulation of the intelligent speed meter based on AT89c51. I would like to ask for your advice.
My speed measurement range is 10-----1000rpm. After calculation, I use the cycle measurement method to measure. I only need to measure one pulse width! There is a problem with the simulation now. It i...
小小2008鸟 MCU
Types of MOS tubes in Wien bridge
For this voltage stabilizing circuit made of MOS tubes, can only N-type MOS tubes be used?...
S3S4S5S6 Analog electronics
Show off the prizes for the bug catching activity~~
Roo~~ I received the prize two or three days ago, and took photos of it. But I was a bit busy these two days, so I’ve only just posted the prizes now~~ Thanks to EEworld, thanks to the administrators~...
okhxyyo Talking
Problem with TAR counter of timer A
I use a timer to measure time. I want to know when TAR starts counting. Does it start from when TACTL sets the counting mode or from some other time?...
wangfei890912 Microcontroller MCU
About the address of the CAN module on ARM
Since this is my first time to do CAN bus communication, I have some questions to ask you:1. The register in the eCAN module I use has an ID identifier register, so I can add an ID number to the data,...
zengjiangyi Embedded System
Problems with DSP28027 running HRPWM routines
I made a minimum 28027 system board myself, and it works fine for running GPIO and EPWM routines. But when running the HRPWM routine, it automatically disconnects at full speed. [/font][/backcolor][/c...
chenbingjy Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2596  496  2146  1982  1431  53  10  44  40  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号