POWER/SIGNAL RELAY, 3PST, MOMENTARY, 0.051A (COIL), 24VDC (COIL), 1200mW (COIL), PANEL MOUNT
CategoryMechanical and electronic products    relay   
File Size538KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

KUMP-13D48-24 Overview

POWER/SIGNAL RELAY, 3PST, MOMENTARY, 0.051A (COIL), 24VDC (COIL), 1200mW (COIL), PANEL MOUNT

KUMP-13D48-24 Parametric

Parameter NameAttribute value
MakerTE Connectivity
Reach Compliance Codeunknown
ECCN codeEAR99
body width35.71 mm
body height48.41 mm
Body length or diameter38.89 mm
Maximum coil current (DC)0.051 A
Coil operating voltage (DC)18 V
Coil power1200 mW
Coil resistance472 Ω
Maximum coil voltage (DC)24 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load15A@277VAC
Maximum contact current (AC)15 A
Maximum contact voltage (AC)277 V
Contact/Output Power TypeAC
Electrical life100000 Cycle(s)
Installation featuresPANEL MOUNT
operating hours15 ms
Maximum operating temperature70 °C
Minimum operating temperature-45 °C
physical size38.89mm x 35.71mm x 48.41mm
GuidelineCSA
Relay actionMOMENTARY
Relay function3PST
Relay typePOWER/SIGNAL RELAY
release time10 ms
sealDUST PROOF
surface mountNO
Termination typeSOLDER
Catalog 1308242
Issued 3-03 (PDF Rev. 1-06)
P&B
KU
series
KUP Enclosed Relay
KUIP 8mm Coil to Contacts
KUGP 3mm Contact Gap, 8mm Coil to Contacts
KUEP 10 Amp 150VDC Load Switching
KUMP 15 Amp 277VAC
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent approvals
files of the agencies/laboratories and review them to ensure the product meets
the requirements for a given application.
Features
• AC coils: 6-240VAC, 50/60 Hz. DC: 6-110VDC.
• Contact arrangement up to 4PDT.
• Wide selection of termination and mounting styles.
• PC terminals available.
• Push to test button and indicator lamps.
• KUEP incorporates a blow out magnet for high voltage DC switching.
• KUIP offers 8mm contact-to-coil spacing for a higher degree of isolation.
• KUGP provides 3mm contact gap and 8mm contact-to-coil spacing.
• Complete line of sockets and DIN rail.
• Class B coil insulation.
Coil Data @ 25°C
Voltage:
6 to 110VDC and 6 to 240VAC.
Nominal Coil Power:
DC Coils:
1.2 Watts - KUP KUIP KUMP 1 - 3 pole; KUEP 1 pole.
,
,
,
,
DC Coils:
1.8 Watts - KUP 4 pole; KUEP 2 pole; KUGP
,
,
.
AC Coils:
2.0VA - KUP KUIP 1 - 2 pole; KUEP 1 pole.
,
,
,
AC Coils:
2.7VA - KUP KUIP 3 pole; KUEP 2 pole; KUGP KUMP
,
,
,
,
.
Coil Data
Contact Data @ 25°C
Arrangements:
See respective ordering information table.
Materials:
Fine silver (5 amp) silver-cadmium oxide (10 amp).
Gold flash available as standard.
Gold diffused and gold alloy on special order.
Expected Mechanical Life:
Contact Ratings
Material
Fine
Silver
Arrangement
All
UL/CSA Ratings
5 amps @ 28VDC or 240VAC
80% PF 2.5 amp tungsten
,
@120VAC, 1/2 amp @ 120VDC.
1/6 HP @120VAC, 1/3 HP @
240VAC, 5 FLA, 15 LRA @
250VAC (FLA covered by
30,000 operations).
10 amps @ 28VDC or 240VAC,
80% PF 5 amp tungsten @
,
120VAC, 3A 600VAC, 1/2 amp
@ 120VDC.
1/3 HP @ 120VAC, 1/2 HP @
240, 480, and 600VAC, 10 FLA
30 LRA @ 120VAC, 5 FLA,
15 LRA @ 250VAC.(FLA ratings
covered by 30,000 operations)
15 amp @ 277VAC, 80% PF
KUM KUMP
10 amp @ 28VDC or 120VAC,
80% PF 6 2/3 amp @ 240VAC,
,
80% PF
10 amp per pole not to exceed
30 amp total @ 28VDC, 120VAC,
80% PF 6 2/3 amp @ 240VAC,
,
80% PF
10 amp @ 150VDC
5 amp @ 150VDC
3 amp @ 150VDC
100,000
Expected
Life
DC Volts
Nominal
5
6
12
24
48
110
AC Volts
Nominal
6
12
24
120
240
1.2 Watt
1.8 Watt
DC Ohms ± 10% Nom. I ma DC Ohms ± 10% Nom. I ma
21
238
14
360
32.1
187
20
300
120
100
80
150
472
51
320
75
1,800
26.7
1,260
38
10,000
11
6,720
16
2VA
DC Ohms ± 15%
6
24
85
2,250
9,110
2.7VA
Nom. I ma DC Ohms ± 15% Nom. I ma
335
168
84
17
.5
8.75
4.2
18
72
1,700
7
,200
460
230
115
24
12
100,000
Silver-
Cadmium
Oxide
1-2 Pole
KUP
KUIP
KUGP
KUEP
All KUMP
Operate Data @ 25°C
100,000
KUMP
3 Pole
KUP
KUIP
4 Pole
Must Operate Voltage:
DC Coils:
75% of nominal voltage or less.
AC Coils:
85% of nominal voltage or less.
Operating Time (Excluding Bounce):
15 milliseconds, typical, at nominal voltage.
Release Time (Excluding Bounce):
10 milliseconds, typical, at nominal voltage.
100,000
100,000
Environmental Data
100,000
KUEP
SPST-NO
KUEP
2PST-NO
KUEP
2PDT
(All other AC ratings apply KUEP
.)
Temperature Range:
Operating: Enclosed Relays:
-45°C to maximum listed in table below.
Open Relays:
Add 15°C to maximum listed.
Max C°
KUP
KUIP
KUGP
KUEP
KUMP
AC
2 pole
AC
3 pole
DC
2 pole
+45°C
AC
3-4 pole
+50°C
DC
4 pole
+55°C
+70°C
+75°C
+80°C
+95°C
AC
DC
1-2 pole 1-3 pole
AC
3 pole
AC
2 pole
AC
DC
1 pole
1 pole
AC
DC
1-2 pole 1-3 pole
AC
1-2 pole
DC
2 pole
DC
1-3 pole
Initial Dielectric Strength
Between Open Contacts:
1,200V rms; KUGP 3,500V rms.
,
Between Adjacent Contacts:
2,200V rms.
Between Contacts and Coil:
2,200V rms; KUGP KUIP 3,750V rms.
,
,
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
723
64K PROGRAM memory and 32K DATA memory's MCU
Hello, have you ever used an MCU with about 64K program memory and about 32K data memory? Can you tell me the model? Which company? It would be best if it is all FLASH! EEPROM is also fine! Just don't...
godzh Embedded System
Shaanxi Xinyuan Optoelectronics recruits 2 clerks
Shaanxi Xinyuan Optoelectronics recruits 2 clerks Requirements: enthusiastic and outgoing, proficient in English, strong communication skills, innovative and hardworking spirit. 1. Daily office work s...
sxxyled Recruitment
Serial communication problem of 8-way alarm box
I bought an 8-way alarm box and connected it to COM1 port via a 485-232 connector, but it cannot communicate. The manual says that the alarm box uses three communication protocols: W110, DCTRLS, and S...
rosicky Embedded System
SmartRF05 USB cannot be recognized
SmartRF05 USB cannot be recognized. It was working fine but now it is broken. LCD has no display after power on. Is there any good way to repair it?[[i] This post was last edited by ljt8015 on 2012-4-...
ljt8015 RF/Wirelessly
Research and Application of Omron PLC Network Technology
This paper discusses the network communication function of Omron PLC, and combines the specific example of the monitoring system developed by the author to conduct a detailed analysis and discussion o...
frozenviolet Industrial Control Electronics
ASUS motherboard circuit diagram
View image...
chenhx123 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2728  473  1952  614  1838  55  10  40  13  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号