5 Energy Way, P.O. Box 1019, West Warwick, RI 02893 USA Tel. 800-424-9850 / 401-823-5200 Fax 401-823-8723 Email advintcorp@aol.com Internet http://www.advintcorp.com
.100" (2.54 mm) Pitch Board to Board Interconnections
NB/LNB - Single Row
Molded Female
DRS - Dual Row
Molded Female
NA - Single Row
Molded Male
DRA - Dual Row
Molded Male
KSS - Single Row
Peel-A-Way
®
Female
DKS - Dual Row
Peel-A-Way
®
Female
NEW PHOTO
Low Profile
Board to Board
KSA - Single Row
Peel-A-Way
®
Male
DKA - Dual Row
Peel-A-Way
®
Male
Features:
!
High reliability method of
interconnecting.
!
Reliable mechanical support.
!
Complete flexibility. If the board to
board spacing you need is not shown
on pages 54 - 55 , consult factory.
Terminals and Contacts:
Terminal: Brass - Copper Alloy 360,
ASTM-B-16
Contact: Beryllium Copper - Copper
Alloy 172, ASTM-B-194
Plating:
Terminal: Gold over Nickel or
Tin-Lead over Nickel
Contact: Gold over Nickel or
Tin-Lead over Nickel
Body Material:
Molded -
Glass filled thermoplastic
Polyester (P
.B.T.) U.L. Rated 94V-O,
-60
°
C to 140
°
C (-76
°
F to 284
°
F)
High Temp Molded
- High temp. glass
filled thermoplastic, U.L. Rated 94V-O,
-60
°
C to 260
°
C (-76
°
F to 500
°
F)
Peel-A-Way
®
- Polyimide Film - Temp.
range -269
°
C to 400
°
C(-452
°
F to 752
°
F)
Page 52
How To Order
Single and Dual RowFemale
NB
010
-01
T
G
Contact Plating
G - Gold
T - Tin-Lead
Terminal Plating
G - Gold
T - Tin-Lead
Terminal Type
See page 53 for available
terminal types.
Body Type
NB/LNB - Single Row Molded
HNB/HLNB - Single Row High Temp Molded
KSS - Single Row Peel-A-Way
®
DRS - Dual Row Molded
HDRS - Dual Row High Temp Molded
DKS - Dual Row Peel-A-Way
®
Number of Pins
NB/LNB - 3 - 32, KSS - 2 - 100
DRS - 20 - 70, DKS - 4 - 200
How To Order
Single and Dual Row Male
NA
Body Type
NA - Single Row Molded
HNA - Single Row High Temp Molded
KSA - Single Row Peel-A-Way
®
DRA - Dual Row Molded
HDRA - Dual Row High Temp Molded
DKA - Dual Row Peel-A-Way
®
010
-68
T
Terminal Plating
G - Gold
T - Tin-Lead
Terminal Type
See page 53 for available
terminal types.
Number of Pins
NA/HNA - 3 - 32, KSA - 2 - 100
DRA/HDRA - 20 - 70, DKA - 4 - 200
Peel-A-Way® covered by patent rights issued and or pending.
inch/(mm)
Quick turn delivery available on standard terminal types.
.
5 Energy Way, P.O. Box 1019, West Warwick, RI 02893 USA Tel. 800-424-9850 / 401-823-5200 •Fax 401-823-8723 •Email advintcorp@aol.com •Internet http://www.advintcorp.com
®
®
ADVANCED
Board to Board Interconnections
INTERCONNECTIONS
.100" (2.54 mm) Pitch Board to Board Interconnections
Male Terminal Information
Peel-A-Way® Only
.072 Dia.
(1.83)
.125
(3.18)
.070
(2.16)
.030
(.76)
.125
(3.18)
.125
(3.18)
.018 Dia.
(.46) Typ. 2
.018 Dia.
(.46) Typ. 2
Type -79
Peel-A-Way® Only
.072 Dia.
(1.83)
.125
(3.18)
Type -80
Peel-A-Way® Only
.072 Dia.
(1.83)
.125
(3.18)
.085
(2.16)
.125
(3.18)
Type -81
Type -444
.018 Dia.
(.46)
.125
(3.18)
.052
(1.32)
.103
(2.62)
.125
(3.18)
.018 Dia.
(.46)
.018 Dia.
(.46) Typ. 2
Type -68
.018 Dia.
(.46)
.125
(3.18)
.100
(2.54)
Type -43
.018 Dia.
(.46)
.125
(3.18)
Type -399
.018 Dia.
(.46)
.125
(3.18)
Type -185
.018 Dia.
(.46)
.125
(3.18)
.210
(5.33)
.335
(8.51)
.100
(2.54)
.100
(2.54)
.379
(9.63)
.100
(2.54)
.500
(12.70)
Board to Board
.125
(3.18)
.018 Dia.
(.46)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
Type -42
.018 Dia.
(.46)
.125
(3.18)
Type -398
.018 Dia.
(.46)
.125
(3.18)
Type -403
.018 Dia.
(.46)
.125
(3.18)
Type -71
.018 Dia.
(.46)
.125
(3.18)
.585
(14.86)
.100
(2.54)
.100
(2.54)
.679
(17.25)
.100
(2.54)
.750
(19.06)
.100
(2.54)
.835
(21.21)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
Female Terminal Information
Peel-A-Way® Only
.058 Dia.
(1.47)
Type -210
Peel-A-Way® Only
.058 Dia.
(1.47)
Type -85
Type -299*
.050(1.27) Molded Insulator Thickness
.072 Dia.
(1.83)
Type -49*
.072 Dia.
(1.83)
.015
(.38)
.083
(2.11)
.155
(3.94)
.031
(.79)
.095
(2.41)
.155
(3.94)
.082
(2.08)
.095
(2.41)
.028 Dia.
(.71)
.034 Dia.
(.86)
.038 Dia.
(.97)
.025 Dia.
(.64)
Type -04*
.072 Dia.
(1.83)
Type -51*
.072 Dia.
(1.83)
Type -01
Molded Body Only
.072 Dia.
(1.83)
Peel-A-Way® Only
.072 Dia.
(1.83)
Type -33
.120
(3.05)
.130
(3.30)
.165
(4.19)
.165
(4.19)
.110
(2.79)
.028 Dia.
(.71)
.020 Dia.
(.51)
.110
(2.79)
.125
(3.18)
.020 Dia.
(.51)
.125
(3.18)
.020 Dia.
(.51)
inch/(mm)
* These terminal types are available in either molded or Peel-A-Way®.
Peel-A-Way® covered by patent rights issued and or pending.
The effect is as shown in the figure. The schematic source file is in the attachment. I sent a few PCB libraries. After a brief check, there should be no problem. If it is what you need, please give i...
Being familiar with the kernel's Makefile is very important for developing device drivers and understanding the kernel code structure. Many features of the Linux 2.6 kernel Makefile are very different...
I just started learning DSP. The chip I used is TMS320F2812. When I used the SRAM.CMD file to simulate, the program ran correctly. I used the timer to flip the IO port with a period of 1us. Everything...
I use the Lidar development board, and it was originally written like thisP4SEL |= 0x03;P4DIR|=0X01; // P4.0,1 = USART1 TXD/RXDME2 |= UTXE1 + URXE1; // Enable USART1 TXD/RXDUCTL1 |= CHAR; // 8-bit cha...
0. Introduction
In daily life, we often see some special-purpose vehicles. When these vehicles pass through intersections, they often obtain the right of way at intersections by temporarily op...[Details]
In this article, the high-performance DSP developed by TI can be used as an effective confidentiality method if it is applied to PC encryption cards.
As an effective network security solution,...[Details]
A multi-point temperature control heating control system was designed using the SST89E564RC single-chip microcomputer and a new temperature measuring device. The heating system can be controlled in...[Details]
1. What is temperature?
Heat is a type of molecular motion. The hotter an object is, the faster its molecules move. Absolute zero is defined as the temperature at which all molecular motion ...[Details]
Contact resistance
is the resistance to current flow through a closed pair of contacts. This type of measurement is performed on devices such as connectors,
relays
, and switches. The...[Details]
1 Introduction to HART Protocol
HART (Highway Addressable Remote Transducer), an open communication protocol for addressable remote sensor high-speed channels, was launched by Rosemen in the U...[Details]
my country is a big country in agriculture, grain production and consumption. Grains are a necessary condition for our nation to survive and develop. The flour processing industry will exist forever w...[Details]
This paper designs a 16x16LED Chinese character display bar based on single-chip dynamic scanning control, briefly analyzes the principle of Chinese character display, and studies how the LED displ...[Details]
Since AC mains power may experience power outages, voltage sags and surges, continuous undervoltage and overvoltage, and frequency fluctuations during supply, these factors will affect the continuous ...[Details]
At present, a large number of cooling tower fans, speed fans and special fans are in use in petroleum, chemical, pharmaceutical, metallurgical and other enterprises. Some fans have no monitoring in...[Details]
Our flight had just begun to descend when a gentleman sitting next to me turned to talk to me about engineering—he had seen me reading an engineering journal. The gentleman next to me said that he ...[Details]
LED is now known as the fourth generation of light sources. High-power LED has many advantages over traditional light sources in outdoor lighting.
1 LED lamps have high light efficiency
C...[Details]
1. The composition and structure of mobile phone lithium battery
Mobile phone lithium batteries are mainly composed of plastic shell upper and lower covers, lithium battery cells, protection c...[Details]
This article focuses on closing the feedback loop of an isolated power supply using a TL431 shunt regulator. The article discusses a method to extend the bandwidth of the power supply control loop ...[Details]
There are many types and styles of digital voltmeters in design and development. Traditional digital voltmeters have their own characteristics. They are suitable for manual measurement on site. Tra...[Details]