EEWORLDEEWORLDEEWORLD

Part Number

Search

72416-P

Description
Barrier Strip Terminal Block, 25A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size104KB,2 Pages
ManufacturerMolex
Websitehttps://www.molex.com/molex/home
Download Datasheet Parametric View All

72416-P Overview

Barrier Strip Terminal Block, 25A, 1 Row(s), 1 Deck(s)

72416-P Parametric

Parameter NameAttribute value
MakerMolex
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPLASTIC, PANEL MOUNTABLE, 94V-0
Fastening methodSCREW
Manufacturer's serial number72
Installation typeBOARD
Number of layers1
Rows1
Number of channels16
Rated current25 A
Rated voltage300 V
safety certificateUL; CSA
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
SERIES 72
SERIES 72
BEAU Terminal Blocks
BEAU
.375" PCB Barrier Terminal Strip
Description
The series 72 PCB terminal strip is a
workhorse and our most popular product
series. The product can be configured
from 15 to 25 Amps and from 150 to 300
Volts.
The product is available in standard
and tri-barrier construction and can be
configured with a broad selection of
screws, hardware, mounting and terminal
options.
Made in the USA, all Beau terminal
blocks embody the highest quality
standards in the industry-using the finest
materials and world class manufacturing
processes. They meet or exceed all
applicable industry standards.
Features
Standard and Tri-barrier construc-
tion
is available to provide the
packaging options you need.
Robust and durable,
72 series screw
terminals are ultrasonically
welded into the thermoplastic
insulator, eliminating terminal
twisting and associated solder joint
failure.
Molded to exact length,
with no
ugly saw cuts, Beau terminal strips
make your products look more
professional.
Wide variety of options.
Our broad
range of screw, terminal, hardware
and mounting options allows us to
save you assembly costs and improve
interconnect performance.
PRODUCT RATINGS
#6-32 BINDING HEAD SCREW
UL
Class B
15 Amps @ 300 V 14 AWG
Class C
15 Amps @ 150 V 14 AWG
CSA
Class B
Class C
20 Amps @ 300 V 14 AWG
20 Amps @ 300 V 14 AWG
TECHNICAL SPECIFICATIONS
ELECTRICAL
DWV
IR
MECHANICAL
Tightening torque
Maximum torque
Wire strip length
Wire range
OPTIONS
-45
-47
-49
-45-56
-50
-58
-59
-C
-E
-F
-M
-P
Slotted screw
Screws up, wire ready
Brass, phillips/slotted screw
Stainless steel screw, slotted
Clamp washer, phillips/slotted screw
No screws, barrier only
Screws supplied unassembled
No mounting ends
Solid mounting ends
Rap-attach mounts
3.5 M screw, slotted
.040" standoff pads
130°C insulator
10500 VDC
>5000 Megohms
12 in-lbs.
13 in-lbs.
5/16"
12 to 24 AWG
#6-32 WIRE CLAMP SCREW
UL
Class B
20 Amps @ 300 V 12 AWG
Class C
20 Amps @ 150 V 12 AWG
CSA
Class B
Class C
25 Amps @ 300 V 12 AWG
25 Amps @ 300 V 12 AWG
ENVIRONMENTAL
Continuous Use Temp
RTI electrical
RTI mechanical w/o impact
110
o
C
110
o
C
NOTE: 3.5M screws carry #6-32 screw
ratings.
-V
AGENCY LISTINGS
UL
CSA
File No. E48521
Guide No. XCFR2
File No. 025562
MATERIALS
Insulator
Terminal
Screws
Thermoplastic,
UL94V-0, black
Brass, tin-lead plate
#6-32, phillips/slotted, steel,
zinc chromate plate
HOW TO ORDER
7 2
SERIES
X
TERMINAL
STYLE
123
567
89
X X - X X
NO. OF
POLES
2 to 26
(Dash #s above
and
opposite page)
OPTIONS
*Consult factory for combinations of screw options.
Molex Industrial Division
New England Operations
Gilford, NH 03246-6600
Phone
(603) 524-5101
Fax
(603) 524-1627
Internet www.beauint.com
Voice output PWM duty cycle question
I use 430 to collect a piece of speech and store it in flash, but how often should I output it? How should I calculate the duty cycle?...
zzbaizhi Microcontroller MCU
Compilation problem after building a new platform, how to solve it
I used SMDK2410 to generate a new platform. There were no problems with compiling and running. I added Public and Platform to the SMDK2410 folder and changed the dir and source files accordingly. Howe...
passion07 Embedded System
Touchscreen calibration issues
I have a problem now. When calibrating the touch screen now, no matter whether a single point is calibrated or not, just click the cross cursor to point to the next one. After calibrating the five poi...
kgduerlu Embedded System
Low EMI DC/DC Converter PCB Design
IntroductionSince every switching power supply generates broadband noise, it is extremely difficult to integrate DC/DC converters in automotive circuit board networks into automotive control devices w...
木犯001号 Power technology
I have a question about loop delay?
Title: If the buzzer sounds 5 times, it will sound for about 0.5 seconds and stop for one second (when p1.0 outputs 1, the transistor is cut off, the buzzer does not sound, and the machine cycle is 1u...
lyang996 Embedded System
IIC configuration chip register
Use IIC to configure the target chip registers. The same chip has 5 registers that need to be configured. Make an iic module and then call the IIC module in the top-level file. Do I need to call it 5 ...
xiha FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 132  450  1342  1219  737  3  10  28  25  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号