EEWORLDEEWORLDEEWORLD

Part Number

Search

LTGWO40F-TW-B-R/28V

Description
Rocker Switch, DPST, Momentary, Wire Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size112KB,1 Pages
ManufacturerCarling Technologies
Environmental Compliance  
Download Datasheet Parametric View All

LTGWO40F-TW-B-R/28V Overview

Rocker Switch, DPST, Momentary, Wire Terminal, Rocker Actuator, Panel Mount

LTGWO40F-TW-B-R/28V Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCarling Technologies
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeROCKER
body width25.24 mm
body height20.62 mm
Body length or diameter28.45 mm
Contact (AC) maximum rated R load10A@125VAC
Maximum contact current (AC)10 A
Maximum contact voltage (AC)125 V
Electrical life25000 Cycle(s)
illuminationRED LAMP
Manufacturer's serial numberLTG
Installation featuresPANEL MOUNT
Maximum operating temperature66 °C
Minimum operating temperature
surface mountNO
Switch actionMOMENTARY
switch functionDPST
Switch typeROCKER SWITCH
Termination typeWIRE
Carling
Technologies
TG/LTG-Series Rocker Switches
TG/LTG-Series Rocker Switches
The TG-Series Mini Tippette rocker switches are single or
double pole and feature an all nylon double-insulated con-
struction. These switches are designed with snap-in mount-
ing for fast, low cost assembly. The illuminated version
(LTG) is available with either a paddle or rocker actuator.
These AC rated switches are also suitable for low-voltage
DC applications in a wide range of markets including
Appliance, HVAC, Food service, and Transportation.
Dielectric Strength
UL/CSA:
1000V - live to dead metal parts
Electrical Life
50,000 cycles- maintained
25,000 cycles- momentary
Mechanical Life
100,000 cycles
Operating Temperature
32°F to 150°F (0°C to +65.6°C)
.069[1.75] DIA
.156[3.96] DIA
.055[1.40] DIA
6.000[152.40]
.375[9.52]
.250[6.35]
.500[12.70]
1.155[29.33]
.865[21.97]
.050[1.27]
1.240[31.50]
.250[6.35]
.250 TAB (Q.C.)
.250[6.35]
SOLDER LUG
.187[4.74]
.187 TAB (Q.C.)
INTEGRATED WIRE LEAD
(no exposed conductors)
TERMINAL TYPE
.210[5.33]
.812[20.62]
.520[13.20]
1.125[28.57]
.375[9.52]
1.120[28.45]
PADDLE
1.000[25.40]
.994[25.24]
MOUNTING HOLE
Panel Thickness:
.030[.762] min. to
.250[6.35] max.
LTG G O 50 1
-
T B
-
B
-
R
/
125N
1
Base Part Number
2
Circuit
3
Center
Position
4
Rating
5
Termination
6
Actuator
Style
7
Actuator
Color
8
Base Color
9
Lens Color
10
Lamp
Voltage
1 BASE PART NUMBER: SERIES
1
TG
Double Pole, Non-Lighted
LTG
Double Pole with Indicator Lights
2 CIRCUIT
See Circuit Designation Chart Page 17.
3 CENTER POSITION
C
Center OFF, Three position
O
No Center OFF, Two position
4 RATING
40
5A 250VAC, 10A 125VAC, 1/2HP 125-250VAC
41
5A 250VAC, 10A 125VAC
50
10A 250VAC, 15A 125VAC, 3/4HP 125-250VAC
51
10A 250VAC, 15A 125VAC
5 TERMINATION/FUNCTION
solder lug
ON-NONE-OFF
0
(ON)-NONE-OFF
A
ON-NONE-(OFF)
L
ON-NONE-ON
0
ON-NONE-(ON)
A
ON-OFF-ON
0
6 ACTUATOR STYLE
P
paddle
7 ACTUATOR COLOR
2
B
black
8 BASE COLOR
2
B
black
9 LENS COLOR
3
A
amber
10 LAMP VOLTAGE
incandescent
6V
6 volt
12V
12 volt
18V
18 volt
24V
24 volt
28V
28 volt
wire leads
5
F
T
5
F
5
T
rocker
W
white
W
white
C
clear
R
red
neon
125N
125 volt neon
250N
250 volt neon
.250 tab QC
1
B
M
1
B
1
.187 tab QC
3
D
R
3
D
3
NOTES
Imprinting is available. Consult factory.
Panel Cut-Out Recommendations: For sheet metal panels, switch must enter panel in same direction as the punch. (Burr on bottom.) Test cut hole in actual material.
1
TG available with circuits A, B, C, D, E, F ; LTG available with circuits G, H, I, J, M, N, P, Q, R, T, U, V, Y, Z. See page 17.
2
Custom colors are available. Consult factory.
3
Specify lens color for LTG-Series only.
()
Indicates momentary function.
14
www.carlingtech.com
The self-made board has a problem when running the clock program (the program itself is fine). As shown in the picture.
I am a newbie... I made my own board (MSP430F6638), burned the marquee program into it, and it can run. But as long as it involves the clock initialization program, there will be problems. The program...
狐狸不是猫 TI Technology Forum
MSP-FET430UIF cannot be recognized under Linux system? ? ? ?
Recently I want to use MSP-FET430UIF to debug telosb nodes. It needs to be used under Linux system. However, after plugging in MSP-FET430, the dmesg information is printed as follows. It has been stuc...
锦瑟 Microcontroller MCU
Texas Instruments announces first quarter 2014 financial results and shareholder returns
BEIJING (May 7, 2014) – Texas Instruments Incorporated (TI) (NASDAQ: TXN) reported first quarter revenue of $2.98 billion, net income of $487 million and earnings per share of 44 cents. The results in...
azhiking TI Technology Forum
How do I add a program to another program?
I have a serial port debugging program and the source code. I want to move this function interface to another program interface so that I can operate it at the same time. I am a novice and don't under...
xmhyb Embedded System
【New Year's Flavor Competition】Busy Spring Festival
[size=4]{:1_140:}The busy Spring Festival is over, and the managers are back to work~ Good luck to you~ I'm here to share my Spring Festival with you. What was the manager doing on New Year's Eve? Sor...
okhxyyo Talking
How to share resources in multiple windows in evc4.0
I wrote a program in EVC4.0, in which I encapsulated a class and wanted to use it in different windows. How do I declare this instance? Is it declared like a global variable? I don't know where to dec...
jiemei6617 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 638  785  2670  1114  1709  13  16  54  23  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号