EEWORLDEEWORLDEEWORLD

Part Number

Search

3100-30J8999

Description
Definite Purpose Contactor 3-pole, 20-40 FLA AC Coil
File Size74KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet View All

3100-30J8999 Overview

Definite Purpose Contactor 3-pole, 20-40 FLA AC Coil

Catalog 1308242
Issued 3-03 (PDF Rev. 3-04)
PRODUCTS UNLIMITED
Model 98 - 3100
series
Definite Purpose Contactor
3-pole, 20-40 FLA
AC Coil
File E75492
File EN60947-4-1:1991
IEC 947-4-1
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• 3-pole contactors.
• Industry-standard mounting plate.
• Optional interlock/auxiliary switches available.
• Manual test button is standard.
• Coil dust cover helps keep dust and dirt away from magnet and coil area.
• Double E magnet system provides optimal performance.
Environmental Data
Temperature Range:
Storage and Operating: -40°C – +65°C.
Flammability:
UL 94-HB housing.
Mechanical Data
Contact Data @ 25°C
Arrangements:
3 Form X (3PST-NO-DM).
Maximum Ratings:
See Contact Ratings Table.
Material:
Silver Cadmium Oxide.
Contact Termination:
20, 25, 30 FLA Models
Type:
#10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size:
16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque:
25 in.-lbs.
40 FLA Models
Type:
Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size:
14-4 Cu/Al AWG
Tightening Torque:
40 in.-lbs.
Coil Termination:
Dual 0.250” (6.35 mm) quick connects, standard.
A 0.250” quick connect and a #6-32 screw, optional.
Arc Cover:
Optional on 20-30 FLA models, standard on 40 FLA models.
Weight:
16 oz. (455 g) approximately
Coil Data @ 25°C
Voltage:
24 - 480 VAC, 50/60 Hz. See Coil Data Table below.
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Ratings
Full
Load
Amps
20
Number
of
Poles
3
Line
Voltage
240/277
480
600
240/277
480
600
Locked
Rotor
Amps
120
100
80
150
125
100
Resistive
Amps
Rating
30
30
30
35
35
35
Voltage
110/120
200/240
480/600
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
Maximum Horsepower
Single
Phase
1.5
3
-
2
-
5
-
-
2
-
5
-
-
3
-
7.5
-
-
Three
Phase
-
7.5
7.5
-
7.5
10
15
20
-
10
10
15
20
-
10
10
20
25
25
3
30
3
240/277
480
600
180
150
120
40
40
40
40
3
240/277
480
600
240
200
160
50
50
50
Coil Data
Nominal Coil Voltage
Maximum Pickup Volts
Drop-Out Volts Range
Nominal Inrush VA @ 50 Hz
Nominal Inrush VA @ 60 Hz
Nominal Sealed VA @ 50 Hz
Nominal Sealed VA @ 60 Hz
Nominal DC Resistance - Ohms
24
18
6 -15
60
53
6.0
5
7
120
88
20 - 70
60
53
6.0
5
180
208/240
177
40 - 140
60
53
6.0
5
720
277
220
65 - 185
60
53
6.0
5
950
480
384
150 - 270
65
53
6.0
5
3100
Dimensions are shown for
832
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
GPIO Interrupt controller
主晶片:MSP430G2553 目的:透過簡單的GPIO中斷,控制LED以及馬達輸出。 程式碼如下。 [code]#includevoid main(void) {WDTCTL = WDTPW + WDTHOLD; // Disable watchdogP1DIR |= BIT0+BIT4; //Setting P1.0 output P1OUT |= BIT0+BIT4; //Setting P...
kk1010qq Microcontroller MCU
Display SensorTile MIC spectrum on mobile phone
The SensorTile evaluation board integrates a digital microphone MP34DT04The official provides the corresponding routine AudioLoopCan be used to read microphone audio data and play it through the headp...
littleshrimp MEMS sensors
When will tm4c add i2s?
LM3S has i2S peripherals, but TM4C has not yet integrated this peripheral. I am so anxious....
defg Microcontroller MCU
【Help】How to store parameters in FLASH?
For example, I want to write the variable unsigned int para that changes every time at the flash address 0x1000. How can I programthis parameter para when I power on ?Why can't I save it?There is a pr...
kangxin Microcontroller MCU
DIY sun-tracking solar panels (Part 2)
I have posted a post about "DIY Solar Panels That Track the Sun" before, DIY Solar Panels That Track the Sun [url]https://bbs.eeworld.com.cn/forum.php?mod=viewthread&tid=926547&fromuid=1014845[/url] (...
bqgup Energy Infrastructure?
Do a small survey, is it good for girls to do MCU development?
I am learning MCU single-chip computer programming now. I want to ask everyone, are there many girls doing this? I feel that this is very brain-intensive. Is it not suitable for girls? My QQ is 610058...
luishiqi Talking about work

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2106  629  1445  2425  1976  43  13  30  49  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号