3100Y30J8999

Description
Definite Purpose Contactor 3-pole, 20-40 FLA AC Coil
File Size74KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet View All

3100Y30J8999 Overview

Definite Purpose Contactor 3-pole, 20-40 FLA AC Coil

Catalog 1308242
Issued 3-03 (PDF Rev. 3-04)
PRODUCTS UNLIMITED
Model 98 - 3100
series
Definite Purpose Contactor
3-pole, 20-40 FLA
AC Coil
File E75492
File EN60947-4-1:1991
IEC 947-4-1
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• 3-pole contactors.
• Industry-standard mounting plate.
• Optional interlock/auxiliary switches available.
• Manual test button is standard.
• Coil dust cover helps keep dust and dirt away from magnet and coil area.
• Double E magnet system provides optimal performance.
Environmental Data
Temperature Range:
Storage and Operating: -40°C – +65°C.
Flammability:
UL 94-HB housing.
Mechanical Data
Contact Data @ 25°C
Arrangements:
3 Form X (3PST-NO-DM).
Maximum Ratings:
See Contact Ratings Table.
Material:
Silver Cadmium Oxide.
Contact Termination:
20, 25, 30 FLA Models
Type:
#10-32 Screw with quad 0.250” (6.35 mm) quick connects.
Wire Size:
16-8 AWG (Stranding must be split for 8 AWG wire.)
Tightening Torque:
25 in.-lbs.
40 FLA Models
Type:
Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size:
14-4 Cu/Al AWG
Tightening Torque:
40 in.-lbs.
Coil Termination:
Dual 0.250” (6.35 mm) quick connects, standard.
A 0.250” quick connect and a #6-32 screw, optional.
Arc Cover:
Optional on 20-30 FLA models, standard on 40 FLA models.
Weight:
16 oz. (455 g) approximately
Coil Data @ 25°C
Voltage:
24 - 480 VAC, 50/60 Hz. See Coil Data Table below.
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Ratings
Full
Load
Amps
20
Number
of
Poles
3
Line
Voltage
240/277
480
600
240/277
480
600
Locked
Rotor
Amps
120
100
80
150
125
100
Resistive
Amps
Rating
30
30
30
35
35
35
Voltage
110/120
200/240
480/600
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
Maximum Horsepower
Single
Phase
1.5
3
-
2
-
5
-
-
2
-
5
-
-
3
-
7.5
-
-
Three
Phase
-
7.5
7.5
-
7.5
10
15
20
-
10
10
15
20
-
10
10
20
25
25
3
30
3
240/277
480
600
180
150
120
40
40
40
40
3
240/277
480
600
240
200
160
50
50
50
Coil Data
Nominal Coil Voltage
Maximum Pickup Volts
Drop-Out Volts Range
Nominal Inrush VA @ 50 Hz
Nominal Inrush VA @ 60 Hz
Nominal Sealed VA @ 50 Hz
Nominal Sealed VA @ 60 Hz
Nominal DC Resistance - Ohms
24
18
6 -15
60
53
6.0
5
7
120
88
20 - 70
60
53
6.0
5
180
208/240
177
40 - 140
60
53
6.0
5
720
277
220
65 - 185
60
53
6.0
5
950
480
384
150 - 270
65
53
6.0
5
3100
Dimensions are shown for
832
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Request USB to RJ45S circuit diagram
Dear experts, I want to make a USB to RJ45 network port adapter recently, but I have been looking for relevant information on the Internet for a long time and can't find any. Can anyone send me a copy...
sisi85 Integrated technical exchanges
"Play with pyboardCN V2" 02 pyboardCN v2 safe mode and restore factory settings
[i=s] This post was last edited by Isolated Proton on 2018-6-16 20:21 [/i] [size=5][color=#ff0000][b]I. Introduction [/b][/color][/size][size=4] [/size][size=4] [/size] [size=4] In the last chapter, I...
孤立质子 MicroPython Open Source section
VMware implements the problem of using WinDbg on a single machine. WinDbg cannot connect. Please help an expert!
WinDbg connection result Microsoft (R) Windows Debugger Version 6.7.0005.0 Copyright (c) Microsoft Corporation. All rights reserved. Opened \\.\pipe\com_1 Waiting to reconnect... [b]Unable to read hea...
285386409 Embedded System
Why can't I save the parameters I set with the buttons and exit the LCD setting screen?
Why can't I save the parameters I set with the buttons and exit the LCD setting screen?...
ghwhjshtzy 51mcu
Look at a program of msp430 timer UART1 communication
The following program implements the following function: [color=#000000], the timer is set for 1s, the LED lights up once, and a byte of data is sent to UART1. The data sent can be observed using the ...
Jacktang Microcontroller MCU
A Glimpse into the Application and Development of EDA Technology
A Glimpse into the Application and Development of EDA TechnologyPan Song, Hangzhou Institute of Electronic IndustryEDA technology mainly refers to computer technology for ASIC design. Compared with tr...
fighting Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 368  2693  522  2204  1807  8  55  11  45  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号