EEWORLDEEWORLDEEWORLD

Part Number

Search

3100Y30W17999

Description
Definite Purpose Contactor 3-pole, 50-60 FLA 3-pole, 50-60 FLA
File Size84KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet View All

3100Y30W17999 Overview

Definite Purpose Contactor 3-pole, 50-60 FLA 3-pole, 50-60 FLA

Catalog 1308242
Issued 3-03 (PDF Rev. 1-06)
PRODUCTS UNLIMITED
Model 93 - 3100
series
Definite Purpose Contactor
3-pole, 50-60 FLA
AC Coil
File E75492
File EN60947-4-1:1991
IEC 947-4-1
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• 3-pole contactors.
• Convenient “universal” mounting plate.
• Optional interlock/auxiliary switches available.
Environmental Data
Temperature Range:
Storage and Operating: -40°C – +65°C.
Flammability:
UL 94-HB housing.
Mechanical Data
Contact Data @ 25°C
Arrangements:
3 Form X (3PST-NO-DM).
Maximum Ratings:
See Contact Ratings Table.
Material:
Silver Cadmium Oxide.
Contact Termination:
Type:
Box Lug with dual 0.250” (6.35 mm) quick connects.
Wire Size:
14-2 Cu/Al AWG
Tightening Torque:
50 in.-lbs.
Coil Termination:
Dual 0.250” (6.35 mm) quick connects, standard.
A 0.250” quick connect and a #6-32 screw, optional.
Arc Cover:
Standard.
Weight:
32 oz. (910 g) approximately
Coil Data @ 25°C
Voltage:
24 - 480 VAC, 50/60 Hz. See Coil Data Table below.
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Ratings
Full
Load
Amps
50
Number
of
Poles
3
Line
Voltage
Locked
Rotor
Amps
300
250
200
Resistive
Amps
Tungsten/
Ballast
Amps
53
Voltage
110/120
200/208
240/277
480
600
110/120
200/208
240/277
480
600
Maximum Horsepower
Single
Phase
3
7.5
10
-
-
5
7.5
10
-
-
Three
Phase
-
15
15
25
25
-
25
25
30
30
240
480
600
65
65
65
60
3
240
480
600
360
300
240
75
75
75
53
Coil Data
Nominal Coil Voltage
Maximum Pickup Volts
Drop-Out Volts Range
Nominal Inrush VA @ 50 Hz
Nominal Inrush VA @ 60 Hz
Nominal Sealed VA @ 50 Hz
Nominal Sealed VA @ 60 Hz
Nominal DC Resistance - Ohms
24
182
6 -15
140
132
20
14
2.4
120
93
20 - 70
140
132
20
14
45
208/240
177
40 - 135
140
132
20
14
180
277
235
50-180
140
132
20
14
280
480
374
120 - 286
140
132
20
14
852
Dimensions are shown for
834
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Help
Does anyone have a program for controlling a stepper motor with MSP430F149? I hope you can share it or send it to me for reference. I'd be very grateful as a newbie. My email address is 472283165@163....
472283165 Microcontroller MCU
Electronics Design Issues
Can someone help me design a circuit diagram for two buttons A and B? Button a counts! When a is pressed once, twice, and three times, it sends a high level 3 times, 5 times, and 6 times respectively ...
protel123 MCU
About the LPM mode of MSP430
__enable_interrupt(); // Enable interrupts. TACCR0 = 30; // Delay to allow Ref to settle TACCTL0 |= CCIE; // Compare-mode interrupt. TACTL = TASSEL_2 | MC_1; // TACLK = SMCLK, Up mode. LPM0; // Wait f...
soar1991 Microcontroller MCU
Who installed dsp builder 11.0, please help me, please help me.
I installed dsp builder 11.0, but there are only advanced libraries in simulink, no standard libraries, and nothing is displayed. It's not that the contents in the library cannot be displayed. Please ...
luowhu Analogue and Mixed Signal
How does Altium define the scope of special-shaped components?
The package of the battery case that I drew by myself in Altium defaults that other components cannot be placed in the surrounding square area, thus taking up extra placement space. How can I narrow t...
小笨蛋猫 PCB Design
STM8L152R8 low power consumption issue
Has anyone used this microcontroller, the one on the blood glucose meter? How much can the power consumption be minimized when connected to the LCD segment screen and RTC interrupt in halt low power m...
lidonglei1 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2188  1931  515  2425  2246  45  39  11  49  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号