38-R144C1000

Description
Potential Motor Starting Relay 1-pole, 35A, Normally Closed AC Coil
File Size231KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet View All

38-R144C1000 Overview

Potential Motor Starting Relay 1-pole, 35A, Normally Closed AC Coil

Catalog 1308242
Issued 3-03
PRODUCTS UNLIMITED
38
series
Potential Motor Starting Relay
1-pole, 35A, Normally Closed
AC Coil
File E83865
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• Single-pole, normally closed relay used extensively in HVAC applications.
• Variety of mounting positions and brackets.
• Convenient 0.250” (6.35 mm) quick connect terminals.
• Custom-built to meet customer requirements.
Coil Data @ 25°C
Voltage:
130, 170, 214, 256, 336, 395, 420 and 495 VAC, 60 Hz.
Nominal Sealed Power:
5 VA).
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Data @ 25°C
Arrangements:
Normally-Closed.
Materials:
Silver cadmium oxide.
Maximum Rating:
35A inductive @ 277VAC, 0.5 power factor (Break only.)
Expected Life:
750,000 ops, mechanical.
250,000 ops., breaking rated load.
Mechanical Data
Termination:
0.250” (6.35 mm) quick connects (single or dual, model
dependent). Terminals #4 & #6 are dummies for customer
convenience.
Mounting Position:
Each model is calibrated for its specified mounting
position. Pick-up voltage may vary if relay is mounted
in positions other than specified.
Weight:
5.76 oz. (163.8 g) approximately
Initial Dielectric Strength
Initial Breakdown Voltage:
1,554 VAC @ 60 Hz. between live parts and
exposed non-current carrying metal parts.
Ordering Information
Typical Part No.
B
38
-A
144
C
3
000
1. Series:
38 = 1-pole, normally-closed, potential motor starting relay
2. Wiring and Terminal Type (number of QCs at given base locations):
A = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 2 @ loc. 6.
D = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
M = 2 @ loc. 1, 2 @ loc. 2, 2 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
R = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 1 @ loc. 5 and 0 @ loc. 6.
S = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
T = 2 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
Y = 1 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
3. Coil Rating and Calibration:
000-999 = See table on following page for details.
4. Mounting Bracket Style:
C, D, F or J = See drawings below for details.
C
1.59
(40.39)
#8-32
UNC-2B THD.
D
F
J
.500
(12.7)
#8-32
UNC-2B THD.
1.00
(25.4)
1.563
(39.7)
5. Mounting Position:
1, 2, 3, 4, 5 & 6 = See drawings below for details. NOTE: Devices calibrated in specified mounting position only.
1
2
3
4
5
6
6. Customer ID Suffix:
000-999 = Factory assigned customer ID
Standard part numbers listed below are more likely to be available from stock.
Custom parts only.
Dimensions are shown for
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
818
reference purposes only.
TI Davinci DM6446 Development Guide - UBL Porting
[align=left] The programming of UBL is relatively simple compared to UBOOT, KERNEL, ROOTFS, device driver, and DSP development. Let's start with the startup of DAVINCI to understand the position and r...
kooking DSP and ARM Processors
Download and get a gift|Keysight Technology Test Equipment Report
Recently, Keysight Technologies commissioned Dimensional Research to conduct a survey to explore the current challenges in manufacturing high-quality electronic hardware products. In addition, the sur...
EEWORLD社区 Test/Measurement
TI MSP430 series microcontroller serial communication baud rate calculation method
[size=4]TI MSP430 series microcontroller, the baud rate value of the usart module is determined by the following three registers: UxBR0, UxBR1, UxMCTL [/size] [size=4]Baud rate = BRCLK/N, mainly to ca...
灞波儿奔 Microcontroller MCU
vhdl (0 down to 0)
I use xilinx ip multiplexing, and the generated sram wea end is defined as (0 downto 0) type. When I synthesize it, it fails and says: Port of instancehas different type in definition . How do you sol...
lelte Embedded System
MPS New Year Benefits | Register for a chance to win a JD.com card
Since it is a little difficult to participate in the MPS empty shopping cart activity , we have deliberately simplified the participation process and extended the activity time. Register now for a cha...
EEWORLD社区 Power technology
I'd also like to post a difference post: the difference between electrification and electric.
[font=楷体,楷体_GB2312]Both of them actually consume electricity to generate power. Electric vehicles can only use their own power supply, and the voltage is not high (the current highest seems to be 42V)...
hk6108 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2884  2702  2516  462  613  59  55  51  10  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号