152244-0110GG

Description
44 CONTACT(S), FEMALE, STRAIGHT TWO PART BOARD CONNECTOR, SOLDER, SOCKET
CategoryThe connector    The connector   
File Size659KB,4 Pages
Manufacturer3M
Websitehttp://3M.com/esd
Environmental Compliance
Download Datasheet Parametric View All

152244-0110GG Overview

44 CONTACT(S), FEMALE, STRAIGHT TWO PART BOARD CONNECTOR, SOLDER, SOCKET

152244-0110GG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Maker3M
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Is SamacsysN
Other features3M, LOW PROFILE
body width0.16 inch
subject depth0.29 inch
body length1.93 inch
Body/casing typeSOCKET
Connector typeBOARD CONNECTOR
Contact to complete cooperationGOLD (15) OVER NICKEL (150)
Contact point genderFEMALE
Contact materialCOPPER ALLOY
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
DIN complianceNO
Dielectric withstand voltage700VAC V
Filter functionNO
IEC complianceNO
Insulation resistance1000000000 Ω
Insulator colorGRAY
insulator materialGLASS FILLED POLYBUTYLENE TEREPHTHALATE
MIL complianceNO
Plug contact pitch0.079 inch
Match contact row spacing0.079 inch
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of rows loaded2
Maximum operating temperature105 °C
Minimum operating temperature-55 °C
OptionsGENERAL PURPOSE
Plating thickness15u inch
polarization keyCENTER
Rated current (signal)1 A
GuidelineUL
reliabilityCOMMERCIAL
Terminal pitch2 mm
Termination typeSOLDER
Total number of contacts44
UL Flammability Code94V-0
Maximum wire diameter28 AWG
Minimum wire diameter28 AWG
Base Number Matches1
3M
Pak 20 Wiremount Socket
2 mm × 2 mm for 1 mm Pitch Cable
1522 Series
Industry standard compatible
Mates with Pak 20 (2 mm x 2 mm) grid pin strips
Low profile
Preassembled covers
Available with or without strain relief
Available with optional centerbump polarity feature
See the Regulatory Information Appendix (RIA) in
the “RoHS compliance” section of
www.3mconnector.com for compliance information
(RIA E1 & C1 apply)
Date Modified: April 15, 2010
TS-0523-C
Sheet 1 of 3
Physical
Insulation:
Flammability: UL 94V-0
Color: Gray
Material: Glass Filled Polyester (PBT)
Contact:
Underplating and U-Slot: 50 -150 μ” [ 1.27-3.81 μm ] Nickel - QQ-N-290, Class 2
Wire Accommodation: 28 AWG Stranded
Wiping Area: Gold, MIL-G-45204, Type II, Grade C
Plating:
Material:
Copper Alloy
Marking:
3M Logo, Part Identification Number and Orientation Triangle
Note:The location and thickness of the contact plating is determined by the part number. Refer to ordering information.
Electrical
Current Rating:
1A
Insulation Resistance:
> 1 × 10
9
Ω
at 500 V
DC
Withstanding Voltage:
1,000 V
RMS
at Sea Level
Environmental
UL File No.: E68080
Temperature Rating:
-55°C to +105°C
RoHS = Directive 2002/95/EC,
Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment
3
Electronic Solutions Division
Interconnect Solutions
http://www.3Mconnector.com
3M is a trademark of 3M Company.
For technical, sales or ordering information call
800-225-5373
C language BCD code to decimal (hexadecimal HEX) program
[i=s]This post was last edited by tiankai001 on 2018-12-3 12:21[/i] [b][color=#5E7384]This content is originally created by EEWORLD forum user [size=3]tiankai001[/size]. If you need to reprint or use ...
tiankai001 Programming Basics
Dynamic power management technology based on prior knowledge
Abstract: "Dynamic power management" is a design method to reduce power consumption by dynamically allocating system resources to complete system tasks with the least components or the lowest workload...
zbz0529 Power technology
Can vxwork use a PC as the target machine with CPUInter Core Duo?
Which BSP should I choose when making a Build rom? In my tornado 2.2, there are pentium, pentium1, pentium2, pentium3, pentium4, and pentium_mp. I chose pentium_mp and turned on the **_PC_CONSOLE opti...
XWXWANG Embedded System
I have a puzzling question about zigbee networking.
Yesterday I got two CC2538 SmartRF06EB development kits. I debugged them with GenericApp in the protocol stack Z-Stack-Mesh-1.0.0. One board was burned into a coordinator, PANid was set to 0x6018, cha...
chanson RF/Wirelessly
Introduction to the main application instruments of online detection instruments
Ultrasonic level meter, differential level meter, flow meter (1) Screen operation control. One ultrasonic differential level meter is installed on each coarse screen and fine screen. The difference in...
sovlrio Industrial Control Electronics
Help me to make a simulation using Proteus
Experts, please help me make a simulation using proteus[[i] This post was last edited by the 2009th rookie on 2009-2-9 14:38 [/i]]...
第2009菜鸟 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2075  1120  1731  735  1251  42  23  35  15  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号