EEWORLDEEWORLDEEWORLD

Part Number

Search

3EP7M

Description
120 V, 50/60 HZ, SINGLE PHASE EMI FILTER
CategoryPassive components   
File Size61KB,2 Pages
ManufacturerMACOM
Websitehttp://www.macom.com
Download Datasheet Parametric View All

3EP7M Online Shopping

Suppliers Part Number Price MOQ In stock  
3EP7M - - View Buy Now

3EP7M Overview

120 V, 50/60 HZ, SINGLE PHASE EMI FILTER

3EP7M Parametric

Parameter NameAttribute value
working frequency50/60 HZ
stateACTIVE
Installation typePANEL MOUNT
DimensionsL81.5XB57.2XH45.2 (mm)/L3.209XB2.252XH1.78 (inch)
Manufacturer SeriesEP
high capacity2250 V
filter typeSINGLE PHASE EMI FILTER
Rated current3 A
Rated voltage120 V
Maximum leakage current0.2100 mA
Maximum insertion loss frequency66 dB
Minimum insertion loss frequency1 dB
CORCOM Product Guide
RFI Power Line Filters for Switching Power Supply Noise Suppression
EP/VP Series
EP7/VP7
UL Recognized
CSA Certified
VDE Approved
EP1/VP1
EP3/VP3
EP/VP Series
The EP/VP series of RFI filters has been developed to
reduce conducted noise to acceptable limits for
equipment that must comply with the requirements
of CISPR in Europe and the FCC specifications in the USA.
These filters provide high insertion loss for both line-
to-ground and line-to-line emissions throughout the
frequency range. They are particularly well suited
for equipment to better meet both stringent emissions
specifications (such as CISPR 22, A-level and FCC
Part 15J, Class B) and the EP models meet very low
leakage current requirements.
Tyco Electronics Corcom Products has extended the EP
Series of Power Line Filters by adding a 7 Amp and 12
Amp versions to the existing 3, 6, 10, and 20 Amp product
offering. The new filters offer higher performance in a
smaller package at a lower price than the existing 6 Amp
and 10 Amp versions. The smaller package size and
comparable performance is a better match to Schaffner's
FN 2070 Series. The new filters are RoHS compliant.
Specifications
Maximum leakage current,each line-to-ground
VP Models
@ 120 VAC 60 Hz:
.73mA
@ 250 VAC 50 Hz:
1.27mA
Hipot rating (one minute):
line-to-ground
line-to-line
Operating frequency:
Rated voltage (max.):
Rated current:
03EP
3A
06EP
6A
7EP
7A
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Rating
EP
3A
6A,10A
7A
12A
20A
VP
20A
.01
1
1
15
12
3
3
Frequency–MHz
.05 .15 .5
1
5
10
10
28
7
6
2
58
58
63
52
28
42
65
65
75
68
50
60
65
65
78
70
55
65
66
66
75
70
60
65
10
60
60
75
70
55
55
30
25
25
55
45
55
55
EP Models
.21mA
.36mA
2250 VDC
1450 VDC
50/60 Hz
250 VAC
10EP
12EP
20EP/VP
10A
12A
20A
Electrical Schematic
LINE
Tapped insert:
No. 6-32 x 1/4 (2)-EP7
No. M-3 x .5 (2)-EP7M
LOAD
Resistor location for reference only.
D B
A
C
E
Recommended Panel Cutout
.235 R
5.96
.157 Dia. (2)
3.98
.910
23.11
1.295
32.89
1.575
40.01
Panel Cutout (back mount)
Tolerance ±.005 [0.13]
Line-to-line in 50 ohm circuit
Current
Frequency–MHz
1
5
10
Rating
.01 .15 .5
EP
65
65
36 65 65
3A
1
6A,10A
1
30 65 65
65
65
7A
10 43 55 65
68
70
12A
11
7 13 70
70
70
8
25 60 65
65
58
20A
VP
25 60 65
65
58
8
20A
20
58
35
65
65
58
58
30
58
35
50
45
58
58
56
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
Online Logic Analyzer Data
Purgatory Legend-SignalTapII War. ......
zxopenljx FPGA/CPLD
Smart power monitoring and protection system creative progress post + manual control operation demonstration video (with load)
The 6 control branches use 250V/10A relays, so the branch load cannot be greater than 2KW. The experiment carried 2 loads. The first branch carries an electric rice cooker, and the second branch carri...
ltbytyn Renesas Electronics MCUs
FRAM FAQ
...
fish001 Microcontroller MCU
Who knows spn?
What does spn mean? I mean the SPN related to the network on the phone?...
godzh Embedded System
Looking for a program to use DMA to obtain ADC data
As the title says! After the ADC is started, the DMA automatically transfers the data to a set array (or variable) after the conversion is completed!...
ZhengLang Microcontroller MCU
About DC12V to DC1000V solution?
What is the solution for converting DC12V to DC1000V? Does anyone have any solution? The output power of 1000V is very low, no more than 2w, and it is powered by a 12V battery. I don't know if it can ...
jialaolian Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 409  1940  1678  726  431  9  40  34  15  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号