3A, 120VAC/2A, 250VAC, MALE, MAINS POWER CONNECTOR

CORCOM Product Guide
Multi-Function Power Entry Modules with RFI Power Line Filters
LA Series
UL Recognized
CSA Certified
VDE Approved
FLA/XLA/ZLA
LA Series
The LA series is a multi-function power entry connector with
a choice of filtering capabilities. The series features an IEC
power line connector, selectable North American or dual
European fusing capabilities, DPST on/off switch, and
120/240 voltage selection. The filtered LA units provide a
one piece solution to power entry needs and provide a
filtering solution for almost any RFI problem. Their vertical
design is flange mounted.
This series offers three levels of filtering, all carrying UL
recognition, CSA certification, and VDE approval.
FLA Model
– General purpose RFI filter designed for sus-
ceptibility applications, effectively providing RFI control of
line-to-ground noise.
XLA Model
– High performance RFI filter designed to bring
most digital equipment (including switching power sup-
plies) into compliance with FCC Part 15J, Class B conduct-
ed emissions limits.
ZLA Model
– Premium performance RFI filter designed to
bring most digital equipment (including switching power
supplies) into compliance with EN55022, Level B (as well
as FCC Part 15J, Class B) conducted emissions limits.
Voltage Selection
To change selected voltage: remove the fuse cartridge
using a small blade screwdriver or similar tool; select the
desired voltage by matching the arrow on the fuse car-
tridge to the arrow located on the front of the unit (lower
right corner); replace the fuse cartridge
making sure the
voltage selection arrow aligns with the arrow located on
the front of the unit.
Fuse Changing
Remove the fuse cartridge using a small blade screwdriver
or similar tool; for European fusing pull out the sliding fuse
covers located at the top of each fuse compartment; insert
desired fuses; push the sliding fuse covers back in place
and insert the fuse cartridge back into the unit
making sure
the voltage selection arrow aligns with the arrow located on
the front of the unit.
(Note: Single North American or
European fuse placement is always on the side of the
desired voltage selection arrow behind the fuse symbol;
the other compartment may be used as a spare or be left
blank. Dual European fusing capability is available for
220/240 volts only.)
122
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Specifications
Maximum leakage current, each line-to-ground:
@ 120 VAC 60 Hz:
FLA Model
0.25 mA
XLA/ZLA Models 0.30 mA
@ 250 VAC 50 Hz:
Hipot rating (one minute):
line-to-ground
line-to-line
Operating voltages:
Operating frequency:
Rated voltage (max.):
Switch:
All Models
0.50 mA
1500 VAC
1450 VDC
110,120, 220/240 VAC
50/60 Hz
250 VAC
Double-insulated, rated for
50,000 operations at full load.
35 Amp inrush capability
Accepts one 1/4" x 1-1/4" fuse,
or two 5 x 20 mm fuses
.110 [2.79] terminals
Fuse (not included):
Terminals:
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Frequency-MHz
Rating
.01 .05 .15
.5
1
5
FLA
5A
-
-
14
21
26
40
XLA
3A
2
12 21
35
46
44
ZLA
3A
14
28 38
42
40
40
Line-to-line in 50 ohm circuit
Current
Rating
XLA
3A
ZLA
3A
Frequency-MHz
.02 .03 .05 .07 .15 .5 1 5
-
3
-
14
-
29
5
38
33
57
10
46
44
40
30
50
40
40
10
30
50
50
60 65 60 50
72 72 65 55
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com

3EXLA2S Related Products

3EXLA2S 3EZLA2S 5EFLA2S
Description 3A, 120VAC/2A, 250VAC, MALE, MAINS POWER CONNECTOR 3A, 120VAC/2A, 250VAC, MALE, MAINS POWER CONNECTOR 5A, 120VAC/4A, 250VAC, MALE, MAINS POWER CONNECTOR
CCS3.3 (3.2) installation problems and solutions & installation directory description
CCS3.3 (3.2) Installation Problems and Solutions & Installation Directory Description [align=left][align=left][font=宋体][size=9pt]I have recently started to learn DSP. First, I have practiced with TI's...
蔡强人 DSP and ARM Processors
About the connection problem between USB and ActiveSync under WINCE
Regarding the connection problem between USB and ActiveSync under WINCE, I used the YLE2440 core board, which was modeled after the baseboard drawing, but some modules were removed. The USB part is ex...
whl0808 Embedded System
About ADC Configuration
[i=s] This post was last edited by MOAI on 2014-7-20 15:05 [/i] ADCReferenceSet(ADC1_BASE, ADC_REF_INT); After configuration is completed, register GRP(ADC1).REG(ADC_CTL).BFLD(ADC_CTL_VREF) Readable,W...
MOAI Microcontroller MCU
51 latest simulation circuit learning board
51 latest simulation circuit learning board:lol :victory: :victory:...
cernllyy 51mcu
A question about the Embest Edukit-III system
I would like to ask a question about the Embest Edukit-III system. When I insert the ARM9 Samsung S3C2410X chip, the digital tube and touch screen of the Embest Edukit-III system will automatically in...
qddianzi Embedded System
Ask about the op amp LM324
Because there are only +8V and 5V power supplies on the circuit board, and if +8V and GND are used to power LM324, it cannot meet the requirements, because the minimum output of LM324 is required to b...
ATT001 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2838  717  748  2286  683  58  15  16  47  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号