LIMITERS
SINGLE-POLE SINGLE-THROW SWITCHES
FEATURES
• Standard “insertable” SMA connector combination
- SMA plug input/SMA receptacle output
- Field replaceable
• Octave, multioctave and broadband models
Available Upon Request:
• Narrowband models can be optimized
for premium performance
• Lower limiting threshold
• Hermetically sealed
Frequency
Range
(GHz)
• Faster response/recovery time
• Greater power handling (to 60 dBm)
Model
Number
Insertion
Loss
(dB, Max.)
VSWR CW Power
Peak Power
Flat
In/Out
Handling
Handling
Leakage
(Max.) (dBm, Max.) (Watts/Pulse Time µs) (dBm)
Spike
Leakage
(erg)
Recovery
Time
(ns, Max.)
Outline
OCTAVE BANDS
0.5–1
1–2
2–4
4–8
6–12
8–16
LIM-00500100MF
LIM-01000200MF
LIM-02000400MF
LIM-04000800MF
LIM-06001200MF
LIM-08001600MF
0.8
0.8
1
1.6
1.9
2
1.5
1.5
1.5
1.8
1.9
2
30
30
30
30
30
30
50/1 @ 1% DF
50/1 @ 1% DF
50/1 @ 1% DF
50/1 @ 1% DF
50/1 @ 1% DF
50/1 @ 1% DF
18
18
17
17
17
17
0.2
0.2
0.2
0.2
0.2
0.2
50
50
50
50
50
50
174332
174332
174332
174332
174332
174332
BROADBAND
0.5–18
8–18
LIM-00501800MF
LIM-08001800MF
2.7
2.2
2.2
2
30
30
50/1 @ 1% DF
50/1 @ 1% DF
18
17
0.2
0.2
50
50
174332
174332
OPTIMIZED PERFORMANCE MODELS
.004–.025
10–14
LIM-00040025FF
LIM-10001400MF
0.5
2.2
1.5
2
52
43
50/1 @ 1% DF
100/1 @ 1% DF
15
15
0.2
0.2
50
50
174334
174333
ENVIRONMENTAL CONDITIONS
Operating temperature ...... 0 to 70°C
Storage temperature .......... -30 to +85°C
Humidity ............................ 95% noncondensing
Vibration ............................ 12 g’s rms, 20-2000 Hz per MIL-STD-810B Method 514, Procedure 5
LIMITER ORDERING INFORMATION
SINGLE-POLE SINGLE-THROW SWITCHES
To order, please include the following:
Frequency (start/stop)
(500 MHz to 18 GHz model shown)
LIM
-
00501800
-
MF
Connectors (input/output)
(SMA male input with SMA female output shown)
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 439-9220 • FAX: (631) 436-7430 •
www.miteq.com
C-40/51
OUTLINE DRAWINGS
SINGLE-POLE SINGLE-THROW SWITCHES
174332
Ø0.11
[Ø2.6]
THRU
TYP.
4
PLACES
0.39 [9.91]
0.80 [20.32]
.10 [2.54]
.60 [15.24]
OUTPUT
INPUT
1.00
[25.40]
0.10 [2.54]
0.80 [20.32]
0.40 [10.16]
0.29 [7.37]
174333
0.45 [11.43]
OUTPUT
O
0.32 [8.13]
INPUT
Ø0.09
[Ø2.4]
THRU TYP.
2
PLACES
0.90 [22.86]
0.09 [2.29]
0.25 [6.35]
0.50 [12.70]
0.44 [11.18]
0.25 [6.35]
174334
1.86 [47.24]
OUTPUT
INPUT
Ø0.13
[Ø3.2]
THRU
4
PLACES
1.20 [30.48]
0.33 [8.38]
0.75 [19.05]
0.38 [9.65]
0.38 [9.65]
0.75 [19.05]
GENERAL NOTES:
1. Dimensions shown in brackets [ ] are in millimeters.
2. Tolerance as follows: .xx = ±0.01 [.xx = ±0.25], .xxx = ±0.005 [.xxx = ±0.13]
0.13 [3.30]
0.38 [9.65]
0.49 [12.45]
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 439-9220 • FAX: (631) 436-7430 •
www.miteq.com
C-40 /52