8 kV
Kilovac H-18
Make & Break Load Switching
Features:
Smallest DPDT high voltage relay
Vacuum dielectric for power switching low
current loads
8 kV rating; carries 2 Amps at 32 MHz
Tungsten contacts for power switching low
current loads
Meets requirements of MIL-R-83725
Features:
Part Number
PRODUCT SPECIFICATIONS
Units
H-18
DPDT
2C
H-18
Nominal, Volts dc
COIL DATA
12
8
.5 - 5
60
26.5
16
1 - 10
250
115
80
5 - 50
3500
Contact Arrangement ..........................................................
Contact Form ........................................................................
Test Voltage (dc or 60Hz) ...................................................
Rated Operating Voltage
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Continuous Carry Current , Maximum
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Coil Hi-Pot (V RMS, 60 Hz) ...........................................
Contact Capacitance
Between Open Contacts .................................................
Open Contacts to Ground ..............................................
Contact Resistance, Maximum ...........................................
Operate Time, Maximum .....................................................
Release Time, Maximum .....................................................
Shock, 11 ms 1/2 Sine ........................................................
Vibration, 10 Gs Peak .........................................................
Operating Ambient Temperature Range ............................
Mechanical Life (Operations x 10
6
) ....................................
Weight, Nominal (oz) ..........................................................
ohms
ms
ms
G's Peak
Hz
o
Pickup, Volts dc, Maximum
Drop-Out, Volts dc
Coil Resistance (Ohms ±10%)
kV Peak
kV Peak
10
8
5
3
2
Amps
10
7
3
2
500
PART NUMBER SELECTION
Sample Part No.
Model
H-18
Coil Voltage
Blank = 26.5 Vdc
/12Vdc = 12 Vdc
/115Vdc = 115 Vdc
H-18
/12Vdc
pF
0.8
1.5
0.02
15
15
30
55-500
-55 to +125
1
2.5
C
cycles
oz.
37
CII Technologies
/ P.O. Box 4422 / Santa Barbara, CA 93140 /
ph
805.684.4560 /
fax
805.684.9679
/
e-mail
info@kilovac.com /
website
www.ciitech.com