The LT1085 voltage regulators are monolithic inte-
grated circuits designed for use in applications
requiring a well regulated positive output voltage
with low input-output differential voltage.
Note
1) –XX = Voltage Option: 3.3, 5 or 12
–XX = Left blank for Adjustable Option.
Features include full power usage of up to 3A load current, internal current limiting and thermal shutdown. Safe area
protection on the die is also included, providing protection of the series pass Darlington transistor under most conditions.
The hermetically sealed packages are utilised for high reliability and low thermal resistance, whilst the SMD1 package
is also designed for surface mount applications.
ABSOLUTE MAXIMUM RATINGS
(T
case
= 25°C unless otherwise stated)
V
IN
P
D
R
θJC
R
θJC
R
θJC
T
J
T
STG
T
LEAD
Input – Output Voltage Differential
Power Dissipation
Thermal Resistance Junction To Case
Thermal Resistance Junction To Case
Thermal Resistance Junction To Case
Operating Junction Temperature Range
Storage Temperature Range
Lead Temperature (for 10 sec.)
TO–3
TO–3
SMD1
SMD1
TO–257
TO–257
Control
Power
Control
Power
Control
Power
Control
Power
35V
Internally limited *
0.93°C / W
3.0°C / W
0.79°C / W
4.0°C / W
0.79°C / W
4.0°C / W
–55 to 150°C
–55 to 200°C
–65 to 150°C
300°C
* These ratings are only applicable for power dissipations of 28 Watts over a limited range of V
IN
– V
OUT
.
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is
believed to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in
its use. Semelab encourages customers to verify that datasheets are current before placing orders.
denotes specification is applicable over full operating temperature range.
Min. Typ. Max. Unit
3.270 3.300 3.333
V
♦
3.235 3.300 3.365
4.950 5.000 5.050
♦
4.900 5.000 5.100
11.88 12.00 12.12
♦
11.76 12.00 12.24
1.238 1.250 1.262
V
V
V
mV
mV
mV
Parameter
Output
Voltage Test Conditions
V
IN
= 5V, I
OUT
= 0, T
J
= 25°C (K Pack)
3.3V
4.8V
≤
V
IN
≤
15V, 0
≤
I
OUT
≤
I
MAXLOAD
5.0V
12V
V
IN
= 8V, I
OUT
= 0, T
J
= 25°C (K Pack)
6.5V
≤
V
IN
≤
20V, 0
≤
I
OUT
≤
I
MAXLOAD
V
IN
= 15V, I
OUT
= 0, T
J
= 25°C (K Pack)
13.5V
≤
V
IN
≤
25V, 0
≤
I
OUT
≤
I
MAXLOAD
(V
IN
- V
OUT
)= 3V, I
OUT
= 10mA, T
J
= 25°C
V
O
Output Voltage
3,4,6
V
REF
Reference Voltage
4
ADJ.
3.3V
5.0V
1.5V
≤
(V
IN
-
V
OUT
)
≤
25V, 10mA
≤
I
OUT
≤
I
MAXLOAD
♦
1.225 1.250 1.270
4.8V
≤
V
IN
≤
15V, I
OUT
= 0, T
J
= 25°C
0.5
6
4.8V
≤
V
IN
≤
15V, I
OUT
= 0
♦
1.0
6
6.5V
≤
V
IN
≤
20V, I
OUT
= 0, T
J
= 25°C
0.5
10
6.5V
≤
V
IN
≤
20V, I
OUT
= 0
13.5V
≤
V
IN
≤
25V, I
OUT
= 0, T
J
= 25°C
13.5V
≤
V
IN
≤
25V, I
OUT
= 0
1.5V
≤
(V
IN
-
V
OUT
)
≤
15V, I
LOAD
= 10mA, T
J
= 25°C
♦
♦
♦
♦
♦
♦
T
J
= 25°C
(V
IN
- V
OUT
) = 3V, 10mA
≤
I
OUT
≤
I
MAXLOAD
♦
♦
♦
♦
♦
ΔV
OUT
= 33mV,I
OUT
= I
MAXLOAD
ΔV
OUT
= 50mV,I
OUT
= I
MAXLOAD
ΔV
OUT
= 120mV,I
OUT
= I
MAXLOAD
ΔV
OUT
= 1%V ,I
OUT
= I
MAXLOAD
♦
1.0
1.0
2.0
0.015
0.035
0.050
3
7
5
10
12
24
0.1
0.2
1.3
1.3
1.3
1.3
10
25
25
0.2
0.2
0.5
15
20
20
35
36
72
0.3
0.4
1.5
1.5
1.5
1.5
REG
(LINE)
Line Regulation
2,3
12V
ADJ. 1.5V
≤
(V
IN
-
V
OUT
)
≤
15V, I
LOAD
= 10mA
15V
≤
(V
IN
-
V
OUT
)
≤
35V
3.3V
5.0V
REG
(LOAD)
Load Regulation
2,3,4
12V
V
IN
= 5V, 0
≤
I
OUT
≤
3A, T
J
= 25°C
V
IN
= 5V, 0
≤
I
OUT
≤
3A
V
IN
= 8V, 0
≤
I
OUT
≤
I
MAXLOAD,
T
J
= 25°C
V
IN
= 8V, 0
≤
I
OUT
≤
I
MAXLOAD
V
IN
= 15V, 0
≤
I
OUT
≤
I
MAXLOAD,
T
J
= 25°C
V
IN
= 15V, 0
≤
I
OUT
≤
I
MAXLOAD
(V
IN
- V
OUT
) = 3V,10mA
≤
I
OUT
≤
I
MAXLOAD
,
ADJ.
3.3V
V
D
Dropout Voltage
5
%
mV
mV
mV
%
5.0V
12V
ADJ
V
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is
believed to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in
its use. Semelab encourages customers to verify that datasheets are current before placing orders.
denotes specification is applicable over full operating temperature range.
Min. Typ. Max. Unit
3.270 3.300 3.333
V
♦
3.235 3.300 3.365
4.950 5.000 5.050
♦
4.900 5.000 5.100
11.88 12.00 12.12
♦
11.76 12.00 12.24
1.231 1.250 1.268
V
V
V
mV
mV
mV
Parameter
Output
Voltage Test Conditions
V
IN
= 5V, I
OUT
= 0, T
J
= 25°C (K Pack)
3.3V
4.8V
≤
V
IN
≤
15V, 0
≤
I
OUT
≤
I
MAXLOAD
5.0V
12V
V
IN
= 8V, I
OUT
= 0, T
J
= 25°C (K Pack)
6.5V
≤
V
IN
≤
20V, 0
≤
I
OUT
≤
I
MAXLOAD
V
IN
= 15V, I
OUT
= 0, T
J
= 25°C (K Pack)
13.5V
≤
V
IN
≤
25V, 0
≤
I
OUT
≤
I
MAXLOAD
(V
IN
- V
OUT
)= 3V, I
OUT
= 10mA, T
J
= 25°C
V
O
Output Voltage
3,4,6
V
REF
Reference Voltage
4
ADJ.
3.3V
5.0V
1.5V
≤
(V
IN
-
V
OUT
)
≤
25V, 10mA
≤
I
OUT
≤
I
MAXLOAD
♦
1.219 1.250 1.281
4.8V
≤
V
IN
≤
15V, I
OUT
= 0, T
J
= 25°C
0.5
6
4.8V
≤
V
IN
≤
15V, I
OUT
= 0
♦
1.0
6
6.5V
≤
V
IN
≤
20V, I
OUT
= 0, T
J
= 25°C
0.5
10
6.5V
≤
V
IN
≤
20V, I
OUT
= 0
13.5V
≤
V
IN
≤
25V, I
OUT
= 0, T
J
= 25°C
13.5V
≤
V
IN
≤
25V, I
OUT
= 0
1.5V
≤
(V
IN
-
V
OUT
)
≤
15V, I
LOAD
= 10mA, T
J
= 25°C
♦
♦
♦
♦
♦
♦
T
J
= 25°C
(V
IN
- V
OUT
) = 3V, 10mA
≤
I
OUT
≤
I
MAXLOAD
♦
♦
♦
♦
♦
ΔV
OUT
= 33mV,I
OUT
= I
MAXLOAD
ΔV
OUT
= 50mV,I
OUT
= I
MAXLOAD
ΔV
OUT
= 120mV,I
OUT
= I
MAXLOAD
ΔV
OUT
= 1%V ,I
OUT
= I
MAXLOAD
♦
1.0
1.0
2.0
0.015
0.035
0.050
3
7
5
10
12
24
0.7
0.8
1.3
1.3
1.3
1.3
10
25
25
0.2
0.2
0.5
15
20
20
35
36
72
1.25
1.65
1.5
1.5
1.5
1.5
REG
(LINE)
Line Regulation
2,3
12V
ADJ. 1.5V
≤
(V
IN
-
V
OUT
)
≤
15V, I
LOAD
= 10mA
15V
≤
(V
IN
-
V
OUT
)
≤
35V
3.3V
5.0V
REG
(LOAD)
Load Regulation
2,3,4
12V
V
IN
= 5V, 0
≤
I
OUT
≤
3A, T
J
= 25°C
V
IN
= 5V, 0
≤
I
OUT
≤
3A
V
IN
= 8V, 0
≤
I
OUT
≤
I
MAXLOAD,
T
J
= 25°C
V
IN
= 8V, 0
≤
I
OUT
≤
I
MAXLOAD
V
IN
= 15V, 0
≤
I
OUT
≤
I
MAXLOAD,
T
J
= 25°C
V
IN
= 15V, 0
≤
I
OUT
≤
I
MAXLOAD
(V
IN
- V
OUT
) = 3V,10mA
≤
I
OUT
≤
I
MAXLOAD
,
ADJ.
3.3V
V
D
Dropout Voltage
5
5.0V
12V
ADJ
%
mV
mV
mV
%
V
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is
believed to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in
its use. Semelab encourages customers to verify that datasheets are current before placing orders.
denotes specification is applicable over full operating temperature range.
Parameter
Output
Voltage Test Conditions
3.3V V
IN
= 8V
5.0V
V
IN
= 10V
V
IN
= 17V
(V
IN
-V
OUT
) = 5V
(V
IN
-V
OUT
) = 25V
V
IN
= 18V
V
IN
≤
20V
V
IN
≤
25V
Over Full Operating Temperature Range
ADJ.
ALL
3.3V
5.0V
1.5V
≤
(V
IN
-
V
OUT
)
≤
25V, 10mA
≤
I
OUT
≤
I
MAXLOAD
T
A
= 25°C, 30ms Pulse
V
IN
= 6.3V, f = 120Hz, C
OUT
=25μF, I
OUT
= 3A
V
IN
= 8V, f = 120Hz, C
OUT
=25μF, I
OUT
= 3A
V
IN
= 15V, f = 120Hz, C
OUT
=25μF, I
OUT
= 3A
(V
IN
-V
OUT
) = 3V, f = 120Hz, C
OUT
=25μF,
C
ADJ
=25μF, I
OUT
= IMAXLOAD ,
Over Full Operating Temperature Range
T
A
= 125°C, 1000 Hours
T
A
= 25°C, 10Hz
≤
f
≤
10kHz
12V
ADJ.
3.3V
Min.
♦
3.2
♦
♦
♦
♦
♦
♦
♦
♦
♦
♦
3.2
3.2
3.2
0.2
Typ.
4.0
4.0
4.0
4.0
0.5
5.0
5.0
5.0
5.0
Max.
Unit
I
L
Current Limit
A
10.0
10.0
10.0
10.0
120
μA
mA
I
Q
Quiescient/MinLoad
Current
Adjust Pin Current
Adjust Pin Current
Change
5.0V
12V
ADJ. (V
IN
-V
OUT
) = 25V
I
PIN
ΔI
PIN
0.2
5.0
Thermal Regulation
0.004 0.020 %/W
♦
♦
♦
♦
♦
60
60
54
60
72
68
60
75
0.5
0.3
0.003
1.0
%
%
%
dB
Ripple Rejection
4
12V
ADJ.
Temperature Stability
Long Term Stability
RMS Output Noise
(% of V
OUT
)
ALL
ALL
ALL
Note 1
: Absolute Maximum Rating area those values beyond which the
life of a device may be impaired.
Note 2
: See thermal regulation specifications for changes in output volt-
age due to heating effects. Load and line regulation are measured at a
constant junction temperature by low duty cycle pulse testing.
Note 3
: Line and load regulation are guaranteed up to the maximum
power dissipation of 30W. Power dissipation is determined by the
input/output differential and the output current. Guaranteed maximum
power dissipation will not be available over the full input/output range.
Note 4
: I
MAXLOAD
curve is defined as the minimum value of current limit
as a function of input to output voltage. Note that the 30W power dissipa-
tion for the LT1085 series is only achievable over a limited range of input
to output.voltage.
Note 5
: Dropout voltage is specified over the full output current range of
the device.
Note 6
: Full load current is not available at all input-output voltages. See
Notes 3, 4,
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is
believed to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in
its use. Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is
believed to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in
its use. Semelab encourages customers to verify that datasheets are current before placing orders.
I bought a Launchpad 5529, and I have some basic knowledge of Arduino. I am going to use Energia to develop 430. However, the program I compiled cannot be uploaded, cannot be uploaded, cannot be uploa...
[i=s]This post was last edited by jinglixixi on 2022-1-19 19:28[/i]The reason why the two development boards are compared together is actually accidental, that is, both of them use rt-thread studio as...
As shown in the figure, the level of the I2C pull-up resistor of the chip is 1.8V.
If the microcontroller controls the high level of IO to 3.3V, can it work normally?This question came up after readin...
Common problems and solutions during Linux-2.6 kernel transplantation 1. After the kernel is started, the following prompt appears and then stops: Uncompressing Linux.....................................
I went cycling last night and met a big guy. He said that this was his first time cycling in 2021. He bought some bicycle parts from overseas in the winter of 2020. Due to the epidemic and other reaso...
[align=left][b][size=14.0pt]DIY[/size][/b][b][font=宋体][size=14.0pt]Introduction:[/size][/font][/b][/align][align=left] [font=宋体][size=10.5pt]The DIY[/size][/font]I sent out this time is the final prod...
As more and more consumers purchase new energy vehicles, the safety of electric vehicles has become a major concern. This has been particularly prominent following a series of electric vehicle fire...[Details]
Long ago, the lifespan of cars in my country was 15 years. Once a car reached 15 years old, it was forced to be scrapped. However, the policy was later changed. As long as the car does not exceed 6...[Details]
As the main model among new energy vehicles, pure electric vehicles have received strong support and encouragement from the country in recent years, and their development is changing with each pass...[Details]
In mobile technology, sensors are the primary input for measured signals and form a component of a sensor system. They include sensitive and transducer elements connected to carriers and circuits. ...[Details]
Linear motor modules have become the "sweet spot" in various fields due to their advantages such as long stroke, fast speed, high precision, smooth operation and long life. Different models of line...[Details]
With the increasing popularity of automated equipment, linear modules, a common auxiliary device for automated equipment, have also seen a bright future. In particular, in recent years, many small ...[Details]
Nascent Micro is launching devices covering a wide range of power applications, including gallium nitride (GaN) drivers, dual-channel automotive drivers, and battery protection MOSFETs.
...[Details]
The mobile computing market is rapidly evolving, and manufacturers are fiercely competing for market share. A key area of competition is battery life, which encompasses two key aspects: how long th...[Details]
Introduction: Traditionally, lead-acid batteries have primarily been used to provide backup power and power regulation based on location. In typical applications, the battery's actual use (discharg...[Details]
The drive shaft is a high-speed, low-support rotating body, so its dynamic balance is crucial. Generally, drive shafts undergo dynamic balancing tests and adjustments on a balancing machine before ...[Details]
EVTank predicts that all-solid-state batteries will achieve small-scale mass production in 2027 and large-scale shipments by 2030. Global solid-state battery shipments will reach 614.1GWh, of which...[Details]
New energy electric vehicles are energy-saving, environmentally friendly, have low operating costs, and enjoy strong support from national policies. With the growth in sales of new energy electric ...[Details]
It's not possible to generalize whether one vehicle is good or bad; the definition of "good" varies depending on the environment. Excluding policy support, whether electric vehicles or gasoline-pow...[Details]
This article, part of Texas Instruments' "Power Supply Design Tips" series,
focuses on flyback converter design, discussing key design considerations for a 53VDC to 12V/5A continuous conduction...[Details]
From smartwatches to portable health and fitness trackers, wearable devices are increasingly transforming every aspect of our daily lives. The desktop computer revolution of the 1980s ushered in an...[Details]