Part Number

Search

DF12.A026F150C0.7110.2

Description
Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size1MB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance  
Download Datasheet Parametric View All

DF12.A026F150C0.7110.2 Overview

Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT

DF12.A026F150C0.7110.2 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC/EN 60320-1; IEC/EN 60950; UL 94V-0; CSA; VDE; QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings10A, 250VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Power Entry Modules with Line Filter
www.schurter.com/pg06
IEC Appliance Inlet C14 with Filter, Circuit Breaker TA45 (recessed)
DF2
Standard- or Medical-Filter
C14
70° C
Description
- Panel Mount:
Screw-on mounting from front side
- 3 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2-
pole, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter DF11
- Substitute for type 5145
Characteristics
- All single elements are already wired
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage- or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
- Unwired versions
- Line switch 1-pole
- Other rocker marking
- Medical version M80
- Capacitance CX1
Approvals
- VDE License Number: 40012935
- UL License Number: E72928
References
Weblinks
General Product Information
Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store,
Distributor-Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole non-illuminated or
illuminated acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 100'000 h acc. to MIL-HB-217 F
Circuit Breakers
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Line Switch
Line Filter
MTBF
EMC Products

Regarding the BB-Black programming problem, please help! !
I want to "burn" SPL and UBOOT to emmc via the serial port on the BB-BLACK board. After starting u-boot, I hope to "burn" the kernel to the emmc of the board via TFTP instead of loading it into RAM. I...
dong2213dong DSP and ARM Processors
You can bookmark the official Altium Designer package library
You can collect the official Altium Designer package library [align=left][color=rgb(102, 102, 102)][backcolor=rgb(255, 255, 255)][font=tahoma, Verdana, Arial, 宋体][size=14px], especially the pcb folder...
qwqwqw2088 PCB Design
msp430x24x series microcontroller
I use 2417 and 149. I feel vague about their clock selection and use. I don't have a clear understanding. Can someone give me a more detailed explanation? Thanks in advance....
999626 Embedded System
How to classify the recoverability of exceptions in normal mode?
A written test question from AOTU Technology. I don't understand the meaning of the question at all....
fang314159 Embedded System
Six ways to be a better developer
Based on my own experience, the original author of this article summarizes the following six methods that can help us become a better developer. 1. Talk to other software developers as much as possibl...
呱呱 MCU
Please recommend a microcontroller and a shunt
The microcontroller requires a car-grade 12-16-bit ADC with less than 60 pins and an operating frequency of 50mhz. A development board can be purchased. No overseas purchase is required. The shunt mus...
Locifer Automotive Electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2562  725  1781  1522  503  52  15  36  31  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号