EEWORLDEEWORLDEEWORLD

Part Number

Search

804-019-BB4M7-1PB-72

Description
Interconnection Device
CategoryThe connector    The connector   
File Size508KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

804-019-BB4M7-1PB-72 Overview

Interconnection Device

804-019-BB4M7-1PB-72 Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Other featuresGENDER: FEMALE
Connector typeINTERCONNECTION DEVICE
804-015
Glenair’s ASAP Mighty Mouse
Overmolded Cordsets
offer
environmental protection and
excellent cold temperature flexibility.
These cables are 100% tested and
ready to use. Standard overmolded
cables feature low smoke zero
halogen polyurethane jackets.
Tired of set-up charges and factory
minimums?
Glenair’s Mighty Mouse ASAP
cordsets have no minimum order quantity
and no lot charges.
Abrasion-Resistant Polyurethane Jacket
provides cold temperature flexibility and
high strength. Low smoke/zero halogen
material meets requirements for low
toxicity.
90% Tinned Copper Braid
is terminated
directly to connector with stainless steel
BAND-IT®
strap.
Watertight Overmold
provides strain
relief and protection.
Overmolded Cordset
Series 804 Harsh Environment Shielded Cordsets
These overmolded cordsets withstand abrasion and chemical exposure. Low smoke zero halogen jacket reduces the amount of
toxic and corrosive gasses emitted during combustion. Cable construction features silver coated stranded conductors with TFE
insulation, tinned copper braid shield and extruded polyurethane jacket. Choose single-ended pigtails or double-ended "back-
to-back" versions. Braid shield is attached directly to connector with
BAND-IT®
straps. Semi-rigid polyamide overmold provides
strain relief and environmental sealing.
Series 801 cordsets are now available with size #20HD, #16 and #12 contacts. Ordering information is found on the following
pages.
G
HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Conductors
BAND-IT®
Shield Termination Band
Current Rating
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Solvent Resistance, Polyamide Overmold
Shielding Effectiveness
Cable jacket Flammability and Toxicity
Thermoplastic Polyurethane, Black, Low-Smoke, Zero-Halogen
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
#23 5 Amps, #20HD 7.5 Amps, #16 13 Amps, #12 23 Amps
#23 500 VAC, #20HD 750 VAC, #16 and #12 1800 VAC Sea Level
200 megohms minimum
-30° C. to +105° C.
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2010 Glenair, Inc.
www.glenair.com
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
G-21
Rev. 01-JANUARY-2010
Series 804
Series 804 Push-Pull Mighty Mouse
Overmolded ASAP Cordset Ordering Information
Among many AVR models, only ATMEGA128 does not work for the delay function under ICCAVR...
I have used many types of AVR, such as ATTINY24, ATTINY13, ATMEGA88V, ATMEGA16, and the DELAY delay function under ICCAVR is fine, but the delay of ATMEGA128 under ICCAVR is useless. FOR delay and whi...
gh131413 MCU
Regarding the problem that IAR5 cannot enter interrupt when optimized to high level.
I just started to learn STM32 and encountered a problem. I use IAR5.3. When compiling after writing the program, if the code optimization under C/C++ compile is set to HIGH, the program can run in the...
iamljz stm32/stm8
Interrupt and timer issues
void main(void) {P2=0X0F;EA=1;IT1=1;ET0=1; TMOD=0X01; TH0=-5000/256; //timing 0.01 seconds TL0=-5000/256; TR0=1; FOR(;;); } //interrupt service routine for timer counter 0 void timer0(void) interupt 1...
sp52758 Embedded System
Can I still use the 300M annual card provided by Essence NB-IoT Development Board EC-01F-Kit after the evaluation is over?
Do I need to show my ID card to activate the 300M annual card provided by the EC-01F-Kit, or can I use it right away? Will it be taken back after the evaluation is over, or can I continue to use it fo...
littleshrimp Domestic Chip Exchange
EEWORLD University Hall----PI KOL: Design a reliable switching power supply from scratch
PI KOL: Design a reliable switching power supply from scratch : https://training.eeworld.com.cn/course/26675...
hi5 Power technology
Help!!!
[img]C:\Users\Administrator\Desktop\1.JPG[/img] What does this mean?...
小桥流水0201 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1700  1964  694  831  897  35  40  14  17  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号