MCC
Micro Commercial Components
TM
omponents
20736 Marilla Street Chatsworth
!"#
$
% !"#
PB605
THRU
PB610
6 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
PB-6
B
Features
•
•
•
•
•
Low Forward Voltage and Any Mounting Position
Surge Overload Rating Of 150 Amps
Silver Plated Copper Leads
Lead Free Finish/RoHS Compliant (NOTE 1)("P" Suffix
designates RoHS Compliant. See ordering information)
Case Material: Molded Plastic. UL Flammability
Classification Rating 94V-0 and MSL Rating 1
Maximum Ratings
•
•
•
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
UL Recognized File # E165989
Microsemi
Catalog
Number
PB605
PB61
PB62
PB64
PB66
PB68
PB610
Device
Marking
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
560V
700V
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000V
C
PB605
PB61
PB62
PB64
PB66
PB68
PB610
E
D
G
+
AC
A
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum Forward
Voltage Drop Per
Element
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
Notes:
I
F(AV)
I
FSM
6.0A
150A
T
a
= 50°C
8.3ms, half sine
AC
-
V
F
1.0V
I
F
= 3.0A;
T
a
= 25°C
INCHES
MIN
.578
.230
.750
.405
.038
.145
A
DIMENSIONS
MM
MIN
14.69
5.84
19.10
10.30
0.97
3.70
I
R
10µA
1 mA
T
a
= 25°C
T
a
= 100°C
1.
High Temperature Solder Exemption Applied, see EU Directive Annex Notes 7
DIM
A
B
C
D
E
G
MAX
.618
.270
---
.444
.042
---
MAX
15.71
6.86
---
11.30
1.07
---
NOTE
2PL
2PL
4PL/TYP
∅
Revision:
8
www.mccsemi.com
1 of 3
2008/01/30
MCC
TM
PB605 thru PB610
Figure 1
Typical Forward Characteristics
100
60
40
20
10
6
4
2
Amps 1
.6
.4
.2
.1
.06
.04
.02
.01
.4
.6
.8
1.0
1.2
1.4
1.6
Volts
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
T
a
=25°C
10
6
4
2
1
.6
.4
.2
Micro Commercial Components
Figure 2
Typical Reverse Characteristics
T
a
=25°C
µAmps
.1
.06
.04
.02
.01
.006
.00
4
.002
.001
20
40
60
80
Volts
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
100
120
140
Figure 3
Forward Derating Curve
6.0
Figure 4
Peak Forward Surge Current
300
250
200
5.0
4.0
150
3
.0
Amps
2.0
Amps
100
50
0
1.0
Single Phase, Half Wave
60Hz Resistive or Inductive Load
25
50
75
100
125
150
1
2
4
6
8 10
Cycles
20
40
60 80 100
0
0
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
Average Forward Rectified Current - Amperes
versus
Ambient
Temperature - C
Revision:
8
www.mccsemi.com
2 of 3
2008/01/30
MCC
Micro Commercial Components
TM
Ordering Information
Device
(Part Number)-BP
Packing
Bulk;200pcs/Box
***IMPORTANT NOTICE***
Micro Commercial Components Corp
.
reserves the right to make changes without further notice to any
product herein to make corrections, modifications , enhancements , improvements , or other changes .
Micro Commercial Components Corp
.
does not assume any liability arising out of the application or
use of any product described herein; neither does it convey any license under its patent rights ,nor
the rights of others . The user of products in such applications shall assume all risks of such use
and will agree to hold
Micro Commercial Components Corp
.
and all the companies whose
products are represented on our website, harmless against all damages.
***APPLICATIONS DISCLAIMER***
Products offer by
Micro Commercial Components Corp
.
are not intended for use in Medical,
Aerospace or Military Applications.
www.mccsemi.com
Revision:
8
3 of 3
2008/01/30